Southern California Compounding Pharmacy, LLC
11125 Flintkote Ave Ste F, San Diego, California, United States
FEI 3010006900
FDA has one inspection on file for Southern California Compounding Pharmacy, LLC in San Diego, California (FEI 3010006900). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2019
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Environmental monitoring deficiencies
Personnel and environmental monitoring conducted within the ISO 5 Environments on a[(o)14) l frequency are deficient. Specifically, your firm does not perform growth promotion for each batch of media purchased or use a positive control when conducting'.(15) (4) gloved finger assessment and surface sampling. Your firm conducts gloved fingertip test and surface sampling as part of the compounding personnel qualification.
- Observation 2
Gowning and aseptic practice breaches
Gowning and aseptic practices are deficient. Specifically, during the aseptic operation for Rx# [illegible] on 7/10/19, we observed operator's head enter the ISO 5 Laminar Airflow Workstation (LAFW) during aseptic operations with exposed skin on forehead and cheeks. In addition, operator's skin was exposed at the ankle during aseptic operations and lower back skin was exposed during [(o) (4)] cleaning of the ISO 7 Buffer room.
Show observations 3 to 5
- Observation 3
Cleaning/disinfection procedures deficient
The firm's cleaning and disinfecting procedure in the aseptic processing area are deficient. Add Continuation Page Specifically, Your firm uses non-sterile wipes sprayed with (5) (4) to wipe components prior to introduction into the ISO 5 Laminar Airflow Workstation (LAFW) and to clean ISO 5 LAFW counter top where the sterile drug products are prepared. On 7/10/19, during sterile compounding of Rx# [illegible], operator was observed moving items staged on the ISO 7 buffer room storage table to the ISO 5 LAFW without first sanitizing the items with (5) (4). In addition, your firm utilizes the following non-sterile products to clean the ISO 5 LAFW: (b) (4)
- Observation 4
Inadequate smoke study for airflow
Smoke study conducted on 6/21/2019 to determine unidirectional airflows in ISO 5 LAFW was inadequate. Specifically, the smoke study failed to adequately simulate dynamic conditions and did not provide adequate coverage to demonstrate unidirectional airflow during routine operations. ISO 5 LAFW is where the firm produces all its sterile drug products.
- Observation 5
Laboratory controls lack microbial testing
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, sampling plans, and test procedures designed to assure drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, finished non-sterile drug products are not tested for the presence of microorganisms, for example: Ketoprofen 20%/Lidocaine 10%, lot no. 07419K20L10A, submitted for [illegible] process validation sample did not include a test for the presence of microorganisms. Add. Continuation Page
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010006900 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010006900. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.