Option Care Enterprises
1226 N Michael Dr Ste A, Wood Dale, Illinois, United States
FEI 3012188090
FDA has 2 inspections on file for Option Care Enterprises in Wood Dale, Illinois (FEI 3012188090), from 2016 to 2018. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Mar 6, 2018 that FDAgent has not matched to an inspection on the Data Dashboard.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Sep 21, 2016. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2016–2018
- 1 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- 2 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Poor aseptic practices during TPN preparation
1. Poor aseptic practices were observed. Specifically, on the morning of 01/25/18 while watching a Technician perform the sterile production manipulations to make the bags for Rx o 6 SN o ~ TPN~ b) (4 ml I observed: A. During the required 15 ; addition of the drug component sodium acetate 2 meq/ml to the bag of TPN sterile drug product, the technician placed a finger directly on the junction between the uncapped injection port of the TPN bag and the syringe hub of the syringe being used to make the addition in such a manner as to both contact the unprotected junction with the gloved finger and impede first air to this junction during the addition. B. While placing the uncapped syringe back onto the ISO 5 cabinet working surface after removing the air from bag 5 I observed that the syringe needle touched the surface of the ISO 5 cabinet. The same syringe and needle was used to remove air from bag of the same formulation.
- Observation 2
Nonsterile or uncontrolled disinfectant wipes
2. Disinfecting agents, cleaning pads, and cleaning wipes used for sterile drug production were not always sterile or controlled in a manner as to maintain sterility. Specifically. A. Your firm uses o (~ wipes labeled in part 4) I 11..-'-l..-"-~~~~~~~~~~~~~~~~~~~~~~-' to disinfect the exterior of equipment, components, and container/closures before placing into the ISO 5 cabinets during aseptic processing. The wipes are not labeled as sterile. The wipe manufacturer's technical data sheet for these wipes indicates that o ~ are intended for non-sterile products. B. On 02/06/18 I observed that sterile lint free wipes used to sanitize the ISO 5 classified aseptic processing areas are removed from the manufacturer's packaging and stored uncovered in plastic bins in the ISO 7 area.
Show observations 3 to 4
- Observation 3
Uncontrolled refrigerated pass-through airflow
3. Your facility design allows the influx of poor quality air into a higher classified area. Specifically, I observed that the uncontrolled refrigerated pass through that separates the ISO 7 buffer room from the uncontrolled pharmacy processing area has a refrigeration fan blowing unfiltered chilled air into this space. The refrigerated space is used to pass finished sterile drug product from the ISO 7 buffer room into the uncontrolled pharmacy processing room. I observed that when the door is opened from the ISO 7 buffer room, significant air can be felt coming from this space into the ISO 7 Buffer Room. The firm is not monitoring differential pressures from the buffer room to this space. The firm does not include this uncontrolled refrigerated pass through in its environmental monitoring.
- Observation 4
Inadequate media-fill challenge conditions
4. Media fills were not performed under the most challenging or stressful conditions. Specifically, your procedures for media fills do not fully emulate the number and type of connections used to produce all parenteral nutrition drug products using the ) (~) b) (4). Option Care utilizes an b 4 b) (4) to produce Total Parenteral Nutrition drug products such as Rx b) (6) compounded on 12/28/2017. The o 4 requires the ~) b) (4) during initial set-up and operation b) (4). Aseptic connections are also made b) (4) b 4 ; In addition, up to 5 4) of solution can b 4 during TPN drug production. In contrast, the firm's procedures for media fills in support of TPN production, SOP Pharmacy P-164 "Personnel Training and Evaluation in Aseptic Manipulation Skills" effective 12/15/2017 and its attachment "Process Validation 5) (4) Risk Guideline", requires ~ and transfers only 4) of.................~....____,,
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance2 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- Observation 1
Insanitary aseptic processing practices
OBSERVATION 1 A finished drug product has been prepared, packed, or held under insanitary conditions whereby it may have been contaminated with filth, or whereby it may have been rendered injurious to health. Specifically, appropriate controls to prevent the contamination facility are not in place. • Personnel [illegible] gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated. Gowning worn by employees performing aseptic operations including eyewear, hair [illegible], beard covers (if applicable), face masks, and lab coats/coveralls are stored and donned inside the ante room where the hand sink is located. Per your [illegible]. • Personnel were observed to be moving rapidly in the vicinity [illegible] which disrupted the airflow and increased the risk [illegible] area. Employees were observed on 9/1/2016 [illegible] LAF hoods while other in-process components awaiting aseptic production were staged inside. According to S.K., National Manager [illegible]. • Disinfecting agents and cleaning pads/wipes used in the ISO 5 area are not stored in a manner which maintains sterility prior to use. ISO 5-certified LAF hoods and [illegible] Cleaning and Disinfecting [illegible] these low particle shedding wipes are removed from their primary packaging and stored in the ISO 7 clean room areas for an undetermined length of time inside open-top, red plastic bins above the LAF hoods or on a shelf below the work surface. • Equipment, materials, and/or supplies are not disinfected prior to entering the aseptic processing areas. [An employee] observed on 9/1/2016 using [illegible] did not consistently ensure that the portion of the drug vial, container, or packaging being held by a gloved hand and therefore shielded from contact was [illegible] before moving it into the ISO 5 LAF hoods.
- Citation
New and Unapproved Cite
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012188090 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012188090. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.