Vital Rx, Inc. dba Atlantic Pharmacy and Compounding Form 483, July 2017
FDA issued this Form 483 to Vital Rx, Inc. dba Atlantic Pharmacy and Compounding in Pompano Beach, Florida (FEI 3011775721) at the end of a drug inspection that ended July 20, 2017. It lists 6 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jul 20, 2017
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Jan 17, 2024
- 2,372 days after the inspection
The 6 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Intrathecal preparations not tested
You have no assurance that intrathecal drug preparations prepared by your firm, such as the combination of hydromorphone/bupivacaine 10mg/10mg/ml (preservative free) lot 06132017@6, are safe from endotoxins and sterile since you do not perform endotoxin and sterility testing. These preparations are made using non-sterile starting material such as the hydromorphone HCl lot [illegible] used to prepare the hydromorphone/bupivacaine 10mg/10mg/ml (preservative free) lot 06132017@6.
- 2
Sterile filling and equipment issues
We observed preparations and reviewed documentation for sterile drug products such as multi-use vials for intravenous infusion therapy that were prepared under the conditions listed below: Specifically, we observed the following conditions during the sterile filling preparations of magnesium chloride hexahydrate 20% preservative free lot 06282017@8: 1.) Commercially sterilized vials labeled to have been sterilized on 8/31/2015 with no assigned expiration date were used for this and other sterile drug preparations. You have no assurance that these glass vials remain sterile during this time period. 2.) A f(o)(4) lot [(o)(4)] was used to sterilize [(o)(4)] ml of the magnesium chloride hexahydrate 20% lot 06282017@8. The manufacturer precautions were, '(5)(4) (b)(4)'. The label for the f(6)(4) stated, '(5)(4)'. 3.) The [(b)(4)] integrity [(5)-(4)] was not performed adequately since the [(5)(4)] to determine if the [(I)(J)(4)] was functioning at the appropriate pressure as determined by the manufacturer ([illegible]). 4.) The (6)(4) hood located in the ISO 8 clean room used for weighing and mixing bulk drug substances had an air conditioning filter which was not designed for this piece of equipment. We observed this filter falling onto the working surface of this hood prior to use by the pharmacy technician. We also observed that it was held in place using packing tape which was difficult to clean. 5.) The laminar flow hood (ISO 5) (o)(4) air vent through which first air passes had a visible stain. Additional examples of sterile drug products for weekly IV infusion therapy over 4 weeks prepared under these conditions include: 1.) Ascorbic acid 500 mg/ml for injection multi dose vial lot 06082017@15, BUD 12/5/2017 2.) Vitamin B-complex injectable (b)(4) ml multi dose vial lot 05312017@22, BUD 8/29/2017 3.) Glutathione 200mg/ml (b)(6) ml multi dose vial lot 06062017@21, BUD 11/3/2017
- 3
Inadequate media fill studies
Your form failed to perform adequate media fill studies in that they did not closely simulate aseptic operations incorporating as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, the most recent media fill documentation which demonstrates the ability of your pharmacy technician to prepare sterile drug preparations was performed on 12/20/16 and 1111117 did not include the following: 1.) Dates of media incubation 2.) Temperatures of media incubation 3.) The use of negative controls
- 4
No environmental monitoring
Your form does not perform environmental monitoring for microorganisms. You are not monitoring your sterile ISO 5 laminar flow hood which is used to produce sterile drug products for intrathecal, ophthalmic, and IV infusion use: 1.) You have not performed viable air particle testing 2.) You do not perform surface testing of the laminar flow hood bench 3.) You do not test gloves or suits worn and used during the preparation of sterile drug products
- 5
No sporicidal cleaning agent
You do not have a sporicidal agent for cleaning your ISO 5 laminar flow hood
- 6
Inadequate cleaning; cross-contamination risk
Hazardous and highly potent drugs were prepared and handled without providing adequate cleaning of work surfaces and reusable equipment such as spatulas, beakers, and [(l5)(4)] jars to prevent cross-contamination. Specifically, your operations include the preparation of non-sterile drug products that contain hormones such as progesterone and estriol using reusable equipment that was [(l5)(4)] cleaned using [(l5)(4)] a reusable sponge, [(6)(4)] detergent, and air drying at room temperature. Working surfaces are wiped down using [(o)(4)] [(6)(4)]. You do not have documentation to show that these methods are effective in removing and neutralizing these drug residues. Examples of these preparations are as follows: 1.) The progesterone lot 139103 and estriol lot 1608160057 bulk drug substances were used to prepare Rx 060 [illegible] lot 07052017@9. 2.) The progesterone lot 139103 bulk drug substance was also used to prepare Rx [(b)(6)], [(o)(4)], [(b)(1)] estradiol/progesterone/DHEA 1.5mg/40mg/5mg cream.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterSep 26, 2018CDER · 433 days after this inspection ended
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.