Skip to content

Vital Rx, Inc. dba Atlantic Pharmacy and Compounding

1000 E Atlantic Blvd Rm Ste 110, Pompano Beach, Florida, United States

FEI 3011775721

FDA has one inspection on file for Vital Rx, Inc. dba Atlantic Pharmacy and Compounding in Pompano Beach, Florida (FEI 3011775721). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER). FDA has also posted a Form 483 dated Aug 10, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2017
Inspections with 483 observations shown
1 of 1
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Intrathecal preparations not tested

      You have no assurance that intrathecal drug preparations prepared by your firm, such as the combination of hydromorphone/bupivacaine 10mg/10mg/ml (preservative free) lot 06132017@6, are safe from endotoxins and sterile since you do not perform endotoxin and sterility testing. These preparations are made using non-sterile starting material such as the hydromorphone HCl lot [illegible] used to prepare the hydromorphone/bupivacaine 10mg/10mg/ml (preservative free) lot 06132017@6.

    2. Observation 2

      Sterile filling and equipment issues

      We observed preparations and reviewed documentation for sterile drug products such as multi-use vials for intravenous infusion therapy that were prepared under the conditions listed below: Specifically, we observed the following conditions during the sterile filling preparations of magnesium chloride hexahydrate 20% preservative free lot 06282017@8: 1.) Commercially sterilized vials labeled to have been sterilized on 8/31/2015 with no assigned expiration date were used for this and other sterile drug preparations. You have no assurance that these glass vials remain sterile during this time period. 2.) A f(o)(4) lot [(o)(4)] was used to sterilize [(o)(4)] ml of the magnesium chloride hexahydrate 20% lot 06282017@8. The manufacturer precautions were, '(5)(4) (b)(4)'. The label for the f(6)(4) stated, '(5)(4)'. 3.) The [(b)(4)] integrity [(5)-(4)] was not performed adequately since the [(5)(4)] to determine if the [(I)(J)(4)] was functioning at the appropriate pressure as determined by the manufacturer ([illegible]). 4.) The (6)(4) hood located in the ISO 8 clean room used for weighing and mixing bulk drug substances had an air conditioning filter which was not designed for this piece of equipment. We observed this filter falling onto the working surface of this hood prior to use by the pharmacy technician. We also observed that it was held in place using packing tape which was difficult to clean. 5.) The laminar flow hood (ISO 5) (o)(4) air vent through which first air passes had a visible stain. Additional examples of sterile drug products for weekly IV infusion therapy over 4 weeks prepared under these conditions include: 1.) Ascorbic acid 500 mg/ml for injection multi dose vial lot 06082017@15, BUD 12/5/2017 2.) Vitamin B-complex injectable (b)(4) ml multi dose vial lot 05312017@22, BUD 8/29/2017 3.) Glutathione 200mg/ml (b)(6) ml multi dose vial lot 06062017@21, BUD 11/3/2017

    Show observations 3 to 6
    1. Observation 3

      Inadequate media fill studies

      Your form failed to perform adequate media fill studies in that they did not closely simulate aseptic operations incorporating as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, the most recent media fill documentation which demonstrates the ability of your pharmacy technician to prepare sterile drug preparations was performed on 12/20/16 and 1111117 did not include the following: 1.) Dates of media incubation 2.) Temperatures of media incubation 3.) The use of negative controls

    2. Observation 4

      No environmental monitoring

      Your form does not perform environmental monitoring for microorganisms. You are not monitoring your sterile ISO 5 laminar flow hood which is used to produce sterile drug products for intrathecal, ophthalmic, and IV infusion use: 1.) You have not performed viable air particle testing 2.) You do not perform surface testing of the laminar flow hood bench 3.) You do not test gloves or suits worn and used during the preparation of sterile drug products

    3. Observation 5

      No sporicidal cleaning agent

      You do not have a sporicidal agent for cleaning your ISO 5 laminar flow hood

    4. Observation 6

      Inadequate cleaning; cross-contamination risk

      Hazardous and highly potent drugs were prepared and handled without providing adequate cleaning of work surfaces and reusable equipment such as spatulas, beakers, and [(l5)(4)] jars to prevent cross-contamination. Specifically, your operations include the preparation of non-sterile drug products that contain hormones such as progesterone and estriol using reusable equipment that was [(l5)(4)] cleaned using [(l5)(4)] a reusable sponge, [(6)(4)] detergent, and air drying at room temperature. Working surfaces are wiped down using [(o)(4)] [(6)(4)]. You do not have documentation to show that these methods are effective in removing and neutralizing these drug residues. Examples of these preparations are as follows: 1.) The progesterone lot 139103 and estriol lot 1608160057 bulk drug substances were used to prepare Rx 060 [illegible] lot 07052017@9. 2.) The progesterone lot 139103 bulk drug substance was also used to prepare Rx [(b)(6)], [(o)(4)], [(b)(1)] estradiol/progesterone/DHEA 1.5mg/40mg/5mg cream.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011775721 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011775721. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.