Skip to content

Pharmacy Associates, Inc. dba CompreCare Specialty Pharmacy

1308 4th Ave, Huntington, West Virginia, United States

FEI 3009145318

FDA has one inspection on file for Pharmacy Associates, Inc. dba CompreCare Specialty Pharmacy in Huntington, West Virginia (FEI 3009145318). It ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Aug 3, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2017
Inspections with 483 observations shown
1 of 1
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Non-microbial contamination observed

      Observation #1: Non-microbial contamination was observed in your production area. (b) (4) a.) On 5/9/17, we observed the operator hang bottle onto the side of the trash can while in the ISO 7 clean room during drug product production (aseptic processing) was being performed. The (b) (4) bottle was in direct contact with a non-sterile trash bag in the trash can. The operator continued to use the (b) (4) bottle in the ISO 5 hood while processing Total Parental Nutrition (TPN) (order #050917B) and Hydromorphone Pain Cassette 10 mg/ 1 ml (Control # 1047).

    2. Observation 2

      Improper gowning/donning gloves

      Observation #2: Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated. a.) On 5/10/17, the operator touched her ungloved fingers to the finger-tip portions of the sterile gloves while in the ISO 7 gowning room while donning her gloves. We then observed her working in the ISO 5 hood with these gloves while preparing TPN bags (order #050917A).

    Show observations 3 to 9
    1. Observation 3

      Insufficient glove disinfection

      Observation #3: Personnel failed to disinfect or change gloves frequently enough to prevent contamination. a.) Specifically, on 5/9/17, while observing the pool for the TPN (order # 050917B) the operator touched his glasses and exposed face with his sterile gloves. He sprayed (b) (4) onto the gloves and then immediately went back to working in the ISO 5 hood without allowing drying of the gloves. b.) On 5/9/17, we observed the operator in the ISO 7 clean room with his gloved hands below his waist. He then proceeded to work in the ISO 5 hood without first disinfecting his gloves. On 5/10/17, we observed a different operator in the ISO 7 clean room with her gloved hands below her waist. She then proceeded to work in the ISO 5 hood without first disinfecting her gloves.

    2. Observation 4

      Rapid movement disrupting airflow

      Observation #4: Personnel were observed to be moving rapidly in the vicinity of open sterile units or instruments which disrupted the airflow and increased the risk of bringing lesser quality air into the ISO 5 area. a.) Specifically, on 5/9/17, the operator working in the ISO 5 hood was observed to exhibit quick and erratic, rather than slow and deliberate movements when performing critical operations such as rapidly moving gloved hands after being sprayed with (b) (4) to rapidly dry them. b.) On 5/9/17, we observed the operator leaning into the ISO 5 hood thus obstructing unidirectional airflow in the ISO 5 laminar flow hood. On 5/10/17, during drug production, the operator placed her entire upper torso, arms, and head inside the ISO 5 hood while preparing the TPN bags (order #050917A). On 5/10/17, the operator was observed wearing jewelry (ring and necklace) while working in the ISO 5 hood. We observed the operators street clothing to be exposed while working in the ISO 5 hood. The operators were also observed working in the ISO 5 hood without wearing goggles leaving their eyes, eyelashes and eyebrows exposed to the environment. We also observed the operators working in the ISO 5 hood to have exposed skin areas around the eyes, forehead, ears, beard line, and neck. Furthermore, your firm's gowning components worn by operators working in the ISO 5 hood are not sterile (disposable gowns, hairnets, face-masks, shoe cover booties).

    3. Observation 5

      Non-sterile wipes used

      Observation #5: Disinfecting agents and cleaning pads or wipes used in the ISO 5 area [aseptic processing areas] are not sterile. a.) Specifically, the (b) (4) wipes used to clean the clean room and ISO 5 hood are not sterile and non-shedding.

    4. Observation 6

      No sporicidal agents used

      Observation #6: Sporicidal agents are not used in your facility's clean room and/or ISO 5 area. a.) Specifically, your firm does not use a sporicidal agent for cleaning the ISO 5 hood, ISO 7 clean room and ISO 7 gowning room.

    5. Observation 7

      No personnel environmental monitoring

      Observation #7: Environmental monitoring was not performed in your aseptic processing areas. a.) Personnel Monitoring is not being performed by your firm. Per your firm management, your firm does not have the (b) (4) to perform this testing. Furthermore, the firm does not monitor compounding personnel (i.e. gloved fingers).

    6. Observation 8

      Inadequate media fills simulation

      Observation #8: Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst case activities and conditions that provide a challenge to aseptic operations. a.) Media fills do not simulate your production process under normal operating conditions. For example, your (b) (4) firm does not include the automated system (used for producing TPNs) during media fills. Your firm also does not include the (b) (4) used for processing the non-sterile powder into a sterile liquid (used for producing the Pain Cassettes) during media fills. Your media fills are not performed under worst case aseptic processing conditions, for example the maximum number of operators in the ISO 7 room and interventions.

    7. Observation 9

      No post-filtration integrity testing

      Observation #9: Post filtration integrity testing to the sterilizing filter was not performed. (b) (4) a.) Specifically, no (filter integrity test) has been documented since September 2016. Furthermore, your firm has continued to produce Hydromorphone cassettes which requires a (b) (4) on the (b) (4) filter (non-sterile powder to sterile liquid).

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3009145318 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3009145318. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.