I.V. Specialty, Ltd

3200 Steck Ave Ste 330, Austin, Texas, United States

FEI 3010836489

FDA has 3 inspections on file for I.V. Specialty, Ltd in Austin, Texas (FEI 3010836489), from 2014 to 2017. The latest ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated Sep 12, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below.

FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Eight regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
3, 2014–2017
3 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Vermin observed near production area

      OBSERVATION 1 Vermin was observed present in areas immediately adjacent to your production area. A dead spider was observed in HEPA filter located in the ceiling of the ISO 7 clean room, approximately 10 feet from the ISO 5 laminar air flow (LAF) hood used for sterile drug processing.

    2. Observation 2

      Difficult-to-clean ISO-classified surfaces

      OBSERVATION 2 The ISO-classified areas have difficult to clean, particle-generating, or visibly dirty equipment or surfaces. A. LAF Hood has loose panels covering a light fixture directly above aseptic processing area creating a difficult to clean surface. This equipment is intended to create an ISO 5 aseptic processing environment for sterile drugs. B. LAF Hood has a loose access panel immediately below processing table surface that creates a difficult to clean surface. This equipment is intended to create an ISO 5 aseptic processing area. C. Dirt, debris, stains, and one strand of hair approximately 2 inches long was observed in the front recirculation vent immediately below the aseptic processing surface of the ISO 5 hood. D. LAF Hood is installed on a wood fiber board table with stainless steel, painted, and formica-type surfaces. This multi-surface table creates a difficult to sanitize surface in the clean room. E. There is a office style telephone that creates a difficult to sanitize surface in the clean room. The wiring for the telephone was observed on the floor behind the shelf, creating a difficult to clean space in the ISO 7 room. F. The supply and return air ducts are both located in ceiling of the clean room as well as the ante room. Your pharmacist stated this room is intended to meet ISO 7 and ISO 8 environment standards respectively. G. The door to the ISO 7 clean room is constructed of a wood laminate approximately 15 feet away from the ISO 5 LAF Hood used for processing sterile drugs. This wood laminate creates a difficult to sanitize surface in the clean room. H. The ceiling of the ISO 7 clean room has a tear in the plastic surface of the drop-ceiling tile approximately 13 feet from the LAF Hood used for processing sterile drugs. This tear exposes the dry-wall material behind the plastic layer. Note: Items C, D, E, F, and G are repeat observations from the Inspection in February 2016

    Show observations 3 to 6
    1. Observation 3

      Inadequate aseptic practices observed

      OBSERVATION 3 Aseptic practices in critical area are not adequate for sterile drug processing. On 25 July 2017, we observed: A. The pharmacist touching item on floor and return to processing TPN products without changing gloves. B. The pharmacist using a barcode scanner from outside hood and return to processing without sanitizing gloves.

    2. Observation 4

      Inadequate cleaning/sanitizing procedures

      OBSERVATION 4 Cleaning or Sanitizing of ISO 7 clean room is not adequate. On 25 July 2017, we observed: A. Pharmacist did not use a top-down approach to daily cleaning, the floor was cleaned first, then preparation tables. The bottom shelf of the preparation table was not sanitized where the (b)(4) pump is stored and the legs of the (b)(4) pump were not sanitized. B. The container labeled "Sterile Water" in the clean room is not sterile. Additionally, the container does not have an expiration date, instead a fill date is written on the container. Your pharmacist stated that he fills the bottle with sterile water (b)(4) and uses it to clean "caked" on residue after production in the LAF hood and clean room. C. The sanitizer used in the ISO 7 and ISO 8 rooms (b)(4) is a non-sterile disinfectant.

    3. Observation 5

      Improper incubation of sterility samples

      OBSERVATION 5 Sterility Assurance is not adequate Surface samples collected inside the ISO 5 LAF Hood on (b)(4) basis are not incubated at (b)(4) C per manufacturer instruction. We observed the plates being incubated at (b)(4) without an incubator at approximately [illegible].

    4. Observation 6

      ISO-5 areas not certified dynamically

      OBSERVATION 6 ISO-5 classified areas were not certified under dynamic conditions. Specifically, uni-directional airflow was not verified under operational conditions, based on video dated October 5, 2016 and titled 20161005_104749.mp4

  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Calibration/Inspection/Checking not done

      Routine calibration of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.

    2. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing, processing, packing, and holding of drug products is not appropriate for the duties they perform.

    3. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.

    5. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    Show 4 more citations
    1. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    3. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

  5. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    2. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing, processing, packing, and holding of drug products is not appropriate for the duties they perform.

    3. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    5. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    Show 4 more citations
    1. Calibration/Inspection/Checking not done

      Routine calibration of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.

    2. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

    3. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    4. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.

Regulations FDA cited here

The 7 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010836489 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010836489. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.