I.V. Specialty Ltd. Form 483, July 2017
FDA issued this Form 483 to I.V. Specialty Ltd. in Austin, Texas (FEI 3010836489) at the end of a drug inspection that ended July 28, 2017. It lists 6 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jul 28, 2017
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Jan 17, 2024
- 2,364 days after the inspection
The 6 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Vermin observed near production area
OBSERVATION 1 Vermin was observed present in areas immediately adjacent to your production area. A dead spider was observed in HEPA filter located in the ceiling of the ISO 7 clean room, approximately 10 feet from the ISO 5 laminar air flow (LAF) hood used for sterile drug processing.
- 2
Difficult-to-clean ISO-classified surfaces
OBSERVATION 2 The ISO-classified areas have difficult to clean, particle-generating, or visibly dirty equipment or surfaces. A. LAF Hood has loose panels covering a light fixture directly above aseptic processing area creating a difficult to clean surface. This equipment is intended to create an ISO 5 aseptic processing environment for sterile drugs. B. LAF Hood has a loose access panel immediately below processing table surface that creates a difficult to clean surface. This equipment is intended to create an ISO 5 aseptic processing area. C. Dirt, debris, stains, and one strand of hair approximately 2 inches long was observed in the front recirculation vent immediately below the aseptic processing surface of the ISO 5 hood. D. LAF Hood is installed on a wood fiber board table with stainless steel, painted, and formica-type surfaces. This multi-surface table creates a difficult to sanitize surface in the clean room. E. There is a office style telephone that creates a difficult to sanitize surface in the clean room. The wiring for the telephone was observed on the floor behind the shelf, creating a difficult to clean space in the ISO 7 room. F. The supply and return air ducts are both located in ceiling of the clean room as well as the ante room. Your pharmacist stated this room is intended to meet ISO 7 and ISO 8 environment standards respectively. G. The door to the ISO 7 clean room is constructed of a wood laminate approximately 15 feet away from the ISO 5 LAF Hood used for processing sterile drugs. This wood laminate creates a difficult to sanitize surface in the clean room. H. The ceiling of the ISO 7 clean room has a tear in the plastic surface of the drop-ceiling tile approximately 13 feet from the LAF Hood used for processing sterile drugs. This tear exposes the dry-wall material behind the plastic layer. Note: Items C, D, E, F, and G are repeat observations from the Inspection in February 2016
- 3
Inadequate aseptic practices observed
OBSERVATION 3 Aseptic practices in critical area are not adequate for sterile drug processing. On 25 July 2017, we observed: A. The pharmacist touching item on floor and return to processing TPN products without changing gloves. B. The pharmacist using a barcode scanner from outside hood and return to processing without sanitizing gloves.
- 4
Inadequate cleaning/sanitizing procedures
OBSERVATION 4 Cleaning or Sanitizing of ISO 7 clean room is not adequate. On 25 July 2017, we observed: A. Pharmacist did not use a top-down approach to daily cleaning, the floor was cleaned first, then preparation tables. The bottom shelf of the preparation table was not sanitized where the (b)(4) pump is stored and the legs of the (b)(4) pump were not sanitized. B. The container labeled "Sterile Water" in the clean room is not sterile. Additionally, the container does not have an expiration date, instead a fill date is written on the container. Your pharmacist stated that he fills the bottle with sterile water (b)(4) and uses it to clean "caked" on residue after production in the LAF hood and clean room. C. The sanitizer used in the ISO 7 and ISO 8 rooms (b)(4) is a non-sterile disinfectant.
- 5
Improper incubation of sterility samples
OBSERVATION 5 Sterility Assurance is not adequate Surface samples collected inside the ISO 5 LAF Hood on (b)(4) basis are not incubated at (b)(4) C per manufacturer instruction. We observed the plates being incubated at (b)(4) without an incubator at approximately [illegible].
- 6
ISO-5 areas not certified dynamically
OBSERVATION 6 ISO-5 classified areas were not certified under dynamic conditions. Specifically, uni-directional airflow was not verified under operational conditions, based on video dated October 5, 2016 and titled 20161005_104749.mp4
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3010836489, newest first.
- Form 483, February 2016Inspection ended Feb 5, 2016 · Posted Jan 17, 2024OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.