Environmental monitoring in FDA Form 483 observations
Monitoring cleanrooms and the people in them: viable and nonviable air sampling, settle and contact plates, glove and fingertip samples, and the results that should trigger action. FDAgent finds 179 such observations in 116 Form 483s issued to 109 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 179
- Each quoted below
- Form 483s
- 116
- Posted by FDA
- Facilities
- 109
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 64 in 2026
| Year | Observations |
|---|---|
| 2008 | 2 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 2 |
| 2013 | 0 |
| 2014 | 2 |
| 2015 | 2 |
| 2016 | 11 |
| 2017 | 9 |
| 2018 | 6 |
| 2019 | 5 |
| 2020 | 1 |
| 2021 | 14 |
| 2022 | 14 |
| 2023 | 13 |
| 2024 | 11 |
| 2025 | 23 |
| 2026 | 64 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“environmental monitoring” · “viable” · “nonviable” · “non viable” · “settle plate*” · “contact plate*” · “personnel monitoring” · “fingertip*” · “glove print*” · “glove sampl*” · “particle count*” · “air sampl*” · “surface sampl*” · “EM program*” · “EM sampl*” · “EM data” · “EM excursion*” · “EM result*” · “EM plate*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 179 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 6
… Instead, environmental monitoring of (b)(4) is based on the frequency of typical batch usage and what can be performed at that (b)(4) port. Usage is based on A-SOP-21-01-054, Drug Product (b)(4) Program, v16, dated 6/20/22 which specifies typical batch usage as low, medium or high. Only high usage (b)(4) and (b)(4) used to perform high risk interventions are monitored at the (b)(4) of an aseptic fill. No supporting data could be provided to …
Contains “environmental monitoring”Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 10
… Action 552193 was initiated 6/28/22, to update A-WI-21-06-005-02 to label contact plates in the (b)(4) with marker instead of LIMS labels. The (b)(4) is still used to pass through LIMS labels. This fill line is not dedicated and can be used to aseptically fill both biologic and drug products. B. There is no assurance that media fills are representative of routine production as media fills are not performed under the most challenging or stressful …
Contains “contact plate*”Read the Form 483 →
Carolina InfusionInspection ended Aug 12, 2022 · FEI 3015826782 · Observation 4
… On the same day, viable air sampling was performed; samples were processed by (b)(4) under Sample IDs [illegible]. The room, which is pressure neutral to the hallway adjacent to the sterile compounding cleanroom, recovered both highly pathogenic organisms and CFU counts that exceeded the action limit for the sampling area. Recovered organisms include, but are not limited to, Trichophyton sp., Staphylococcus epidermidis, and Staphylococcus caprae. …
Contains “viable”Read the Form 483 →
Protherics UK Ltd.Inspection ended Jun 23, 2022 · FEI 3001417487 · Observation 3
Classified (b)(4) areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. There is a lack of documented risk based assessments for identifying the environmental monitoring (EM) sample locations. B. (b)(4)-13.009, entitled "Viable Environmental Monitoring Procedures", v27 is deficient in that the above procedures do not define specific EM sample locations when no processing is scheduled.
Contains “environmental monitoring”Read the Form 483 →
Serum Institute of India Pvt. Ltd.Inspection ended Apr 19, 2022 · FEI 3020223359 · Observation 10
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a) You do not perform identification each time action level is reached for each (b)(4) 100 b) Your [illegible] did not consider manufacturing operations when determining sample locations. c) You do not perform complete investigations when an action level is reached to include root cause and corrective action. d) You do not have a …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Dr. Reddy's Laboratories Ltd.Inspection ended Oct 29, 2021 · FEI 3006549835 · Observation 3
Aseptic processing areas are deficient regarding the system. Specifically, you failed to provide scientific justification environmental monitoring process represent the 4) "Re-evaluation for viable monitoring sites 24, 2019. You failed to provide a robust - Equipment ID: 2604824) that could negatively impact aseptically filled [illegible] led for viable monitoring. viable monitoring as the 3) Difficult to clean surfaces identified for …
Contains “environmental monitoring”Read the Form 483 →
Dr. Reddy's Laboratories Ltd.Inspection ended Oct 29, 2021 · FEI 3006549835 · Observation 4
… During- development studies and Cl in the groove of the environment for the Your failed to provide assurance and is free of viable microorganisms. 5) [illegible] or Grade C roo 17 is inadequate. You failed to evaluate against the placed in the room. Additionally, conditions of the r calibration dat of calibration date 6) You failed to adequately challenge you utilized to items used on your distribution studies wer 002-00'. During 7) risk …
Contains “viable”Read the Form 483 →
Dr. Reddy's Laboratories Ltd.Inspection ended Oct 29, 2021 · FEI 3006549835 · Observation 7
… cleaning and conduct settle plate monitoring for the room. justification detailing a reason why surface and active air monitoring was failed to provide assurance that your clean room was brought back to established operating conditions.
Contains “settle plate*”Read the Form 483 →
STAQ Pharma, Inc.Inspection ended Sep 29, 2021 · FEI 3015144909 · Observation 1
… B) The Nonviable (b)(4) and (b)(4) Viable air samplers inside the ISO 5 LFH were not in operation while conducting the Dynamic Smoke Study on 09/17/2020.
Contains “nonviable”Read the Form 483 →
STAQ Pharma, Inc.Inspection ended Sep 29, 2021 · FEI 3015144909 · Observation 2
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, There is no environmental monitoring, including but not limited to, the following ancillary equipment located inside the ISO 5 Laminar Flow Hood (LFH), which is located in (b)(4) Room: A) Non-viable (b)(4) and viable (b)(4) hoses feeding into the LFH through the (b)(4) B) Power cord from (b)(4) (pump located in ISO 7) (b)(4) Room …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
The Compounding PharmacyInspection ended Sep 29, 2021 · FEI 3009127876 · Observation 2
… b) your environmental monitoring process does not sample the AC units or the surrounding tape, and your procedures do not specifically call out that the units are cleaned. (b) (4) (b) (4) (b) (4) c) cleanroom and contain a mini-split type of air conditioning (AC) unit. The equipment, containing a condenser and fan inside the units, are not cleanable without disassembly and therefore are difficult to clean. (b) (4) d) the gap at the back of the AC …
Contains “environmental monitoring”Read the Form 483 →
Pharmcore Inc. dba Hallandale PharmacyInspection ended Sep 24, 2021 · FEI 3014480778 · Observation 2
You did not take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production. Specifically, Your QA Director stated that a thorough '[(b)(4)]' clean is conducted when an objectionable microorganism is found during environmental monitoring of your ISO classified areas. However, your firm failed to thoroughly clean and disinfect the sterile hazardous and …
Contains “environmental monitoring”Read the Form 483 →
Med Shop Total Care Inc.Inspection ended Jul 27, 2021 · FEI 3002835459 · Observation 1
You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production. Specifically, you had several environmental monitoring results in the ISO 5 environment where you did not identify the microorganism and continued to produce and distribute sterile drug products without a complete investigation and …
Contains “environmental monitoring”Read the Form 483 →
Front Door Pharmacy, LLCInspection ended Jun 7, 2021 · FEI 3012937475 · Observation 3
Environmental monitoring was not performed in your aseptic processing areas. Specifically, Environmental Monitoring and measurement frequency of microbiological contamination (viable/non-viable monitoring) of the air in the ISO 5 zone is inadequate. Your pharmacy fail to establish a viable monitoring program during sterile drug production within the ISO 5 LAFU. Additionally, during a review of your pharmacy's cleanroom re-certification for VIABLE …
Contains “environmental monitoring”Read the Form 483 →
Fujifilm Diosynth Biotechnologies USAInspection ended Apr 21, 2021 · FEI 3000718852 · Observation 5
… Events PR180216 and 196559 and deviation PR207669 were opened for excursions of personnel monitoring, in-process sample bioburden, and settle plate monitoring. Organisms recovered were identified to be (b) (4). The firm concluded the organisms were (b) (4) host organism, without considering the possibility of cross-contamination of host organism from other (b) (4) processes.
Contains “personnel monitoring”Read the Form 483 →
Fujifilm Diosynth Biotechnologies USAInspection ended Apr 21, 2021 · FEI 3000718852 · Observation 6
Microbial control of the facility is inadequate. EM excursions were not investigated for root cause and CAPAS implemented were inadequate to control microbial contamination. Specifically, a. (b) (4) environmental and water monitoring summary reports from 2020 documented 30 events of action level Paenibacillus spp. (mostly P. glucanolyticus) recoveries from 57 monitoring sites, 5 events of alert/action level Burkholderia recoveries from 6 …
Contains “EM excursion*”Read the Form 483 →
Emergent Manufacturing Operations Baltimore, LLC.Inspection ended Apr 20, 2021 · FEI 3015448605 · Observation 1
… It is not known how long client (b) (4) virus will remain viable on a surface. There was no additional cleaning performed other than the routine cleaning in response to this deviation. v. There is no assurance that other batches have not been subject to cross-contamination. b. On (b) (4), during the filling of batch (b) (4) bulk drug substance for client (b) (4) released on (b) (4), a (b) (4) leak was observed by the operator. The fill recipe was …
Contains “viable”Read the Form 483 →
Emergent Manufacturing Operations Baltimore, LLC.Inspection ended Apr 20, 2021 · FEI 3015448605 · Observation 8
Equipment used is not of adequate size to facilitate operations for its intended use or for cleaning and maintenance. Specifically, a. On 4/13/2021, (b) dating back to 2/22/2021 were observed in and on top of a plastic container in the (b) (4) inside the microbiology laboratory that is used for testing of client (b) (4) viral drug substance. These (b) included environmental monitoring (b), raw material (b) (4) (b), and microbial limit testing for …
Contains “environmental monitoring”Read the Form 483 →
Imprimis NJOF, -LLCInspection ended Jan 29, 2021 · FEI 3013024146 · Observation 1
… monitoring of personnel performing critical interventions on sterile products during production including, but not limited to, the following examples where personnel monitoring revealed microbial action limit excursions after performing production operations of products intended to be sterile. These batches have been released after concluding that the product sterility was not affected by the microbial excursions. Review of your investigations …
Contains “personnel monitoring”Read the Form 483 →
OSO BioPharmaceuticals Manufacturing, LLCInspection ended Mar 20, 2020 · FEI 1643045 · Observation 1
… e) Operators in aseptic areas may change gloves routinely, always conducted to collect complete environmental monitoring data - the filling room for example, and changes. f) In Filling Line 611, Operators may fully sit operation located in grade. Also, Operators fully sit down in a chair at a desk in the grade conducting paperwork associated with fill checks. h) Your SOP, Cleaning/Decontaminating and Sanitization Areas, for disinfecting the …
Contains “environmental monitoring”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.42Design and construction featuresIn this theme's rule30
- 21 CFR 211.113Control of microbiological contamination27
- 21 CFR 211.160General requirements6
- 21 CFR 211.192Production record review5
- 21 CFR 211.100Written procedures; deviations3
- 21 CFR 211.22Responsibilities of quality control unit2
- 21 CFR 211.63Equipment design, size, and location2
- 21 CFR 211.67Equipment cleaning and maintenance2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2
- 21 CFR 211.194Laboratory records2
Ask FDAgent about environmental monitoring in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.