Catalent Indiana LLC Form 483, September 2022

FDA issued this Form 483 to Catalent Indiana LLC in Bloomington, Indiana (FEI 3005949964) at the end of a drug inspection that ended September 1, 2022. It lists 12 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jul 21, 2023. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Sep 1, 2022
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Jul 21, 2023
323 days after the inspection
Facility
FEI 3005949964
Bloomington, Indiana

The 12 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Failure to thoroughly investigate batch discrepancies

    Your firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components to meet any of its specifications, whether or not the batch has already been distributed. Specifically, A. Per various (b)(4) batch records, the Visible Particles USP <790> testing list a specification of "(b)(4) particles observed**If (b)(4) particle is observed during initial testing, test an additional (b)(4) vials with a cumulative specification of no more than (b)(4) particle observed". Between 8/11/21 and 4/7/22, twelve (b)(4) batches were released after exceeding the supplemental visible particles testing. B. Deviation 523897 regarded an atypical particle found in the (b)(4) on the (b)(4) motor in Zone (b) which lies above the filling line where filling takes place and units are unstoppered during aseptic filling of (b)(4) lot (b)(4) dated 4/28/22. Particle was identified as (b)(4) with (b)(4) material. (b)(4) is not used in the manufacturing of lot (b)(4). (b)(4) is within the formulation of (b)(4) lot (b)(4) which was manufactured directly before this batch. The investigation states, "Client (b)(4) product has been noted to be difficult to clean because of (b)(4) cleaning is performed with (b)(4) WFI and the best cleaning has been noted with (b)(4) WFI". The investigation is isolated to lot (b)(4) and does not extend to other batches previously manufactured after the aseptic filling of (b)(4) which could have been potentially affected by the inadequate cleaning procedure. The investigation did not question how (b)(4) could have potentially contaminated non-product contact equipment which lies above the filling line. Action REC 546084 was initiated on 6/15/22 to change cleaning method. A-SOP-21-01-056 Filling Line Disassembly and (b)(4) Cleaning has yet to be updated to implement (b) WFI to be used during (b)(4) cleaning following a client (b) batch on vial line (b). This change control is still open and is not due to be closed until (b)(4). Deviation 523897 is still open. C. Batches that exceeded internal control limits were not always adequately investigated. For example: The following lots exceeded internal control limit for various categories of visual defects such as Major A defect, defined as Fibers or Intrinsic Particulate (Elongated undissolved matter or particulate matter originating from a normal manufacturing process that is floating freely within the product or that is attached to the product contact area of the stopper), or Major B defect, defined as non-conformities that could lead to serious impairments of the container or potential impact to product quality. Investigation into these limit breaches to determine potential root causes did not occur as appropriate. 1. Product (b)(4) lot #(b)(4) 2. Product (b)(4) lot # (b)(4) 3. Product (b)(4) lot # (b)(4) D. OOS 520278 regarded out of specification result for (b)(4) Particulates Matter for (b)(4) product testing for (b)(4) lot (b)(4) dated 4/21/22. (b)(4) particle was observed, exceeding the specification of (b) foreign particles. Identification determined (b) particles were present, (b)(4) was (b)(4) (potentially from a hair/beard cover) and (b)(4) (potentially from a (b)(4) puncture). No obvious errors were determined to have contributed to the OOS result. Adequate justification could not be provided for only retesting (b)(4) vials during a retest of the (b)(4) Particulates Matter for (b)(4) Product instead of the (b)(4) vials required per the OOS procedure. A-SOP-09-01-019, Investigation of Out of Specification Quality Control Analytical Results, procedure requires a retesting of (b)(4) times the original independent test samples ((b)(4) vials). Deviation 542608, dated 6/8/22, was initiated to address the retesting (b)(4) particulate matter for (b)(4) product testing for (b)(4) lot (b)(4). Sr. Manager of QC stated they wanted to retest (b)(4) samples, but the client felt that since (b)(4) was identified, the initial results were contamina

    Shortened here; the PDF has the full text.

  2. 2

    Inadequate drug complaint investigations and follow-up

    Written records of investigation of a drug complaint do not include the findings of the investigation and the follow-up. Specifically, A. As provided by your firm, a total of 179 complaints were received for particles (foreign matter, particulate matter, black specks, black particles, foreign particle, (b)(4) impurities, black dots and other particulates, dark particles, foreign material, foreign object, (b)(4) particulate, or pieces of (b)(4) in vial) between 03 Sep 2020 to 01 Aug 2022. Complaints were not adequately investigated to include an identification of the particle in the complaint sample. For example: 1. On 23 Mar 2021, a Customer Complaint #333544 reported black specks in four vials of (b)(4), lot# (b)(4). Four vials and four (b)(4) were returned to your firm for evaluation. The black specks were not analyzed in the lab. Retain samples review did not include an inspection for particles. 2. On 01 Feb 2021, a client reported particles in a vial of (b)(4) lot# (b)(4) Customer Complaint #308230. The vial was returned to your firm for evaluation. The particles were not analyzed in the lab. Retain samples review did not include an inspection for particles. B. As provided by your firm, a total of 52 supplier complaints for stopper related issues were submitted between 01 Jul 2019 to 05 Aug 2022. Out of these, 17 supplier complaints were related to Stopper item# 402832. Three of these investigations are still open (SCR 555104, SCR 540975, SCR 534591 opened on 04 Jul 2022, 05 June 2022, and 22 May 2022, respectively). Your firm did not perform an adequate investigation into the repeat stopper defect reported. Your investigation of the 14 supplier complaints related to stopper item #402832 relied in large part on the supplier investigation. For the 14 SCR, the supplier investigations concluded that that stopper item #402832 either "met agreed qualification" or "a root cause cannot be determined". C. Your firm did not adequately extend your complaint investigation to other batches of the same lot or product when warranted. For example, Per the firm's procedure, A-SOP-03-01-024, titled Customer Complaints, Recurring Complaint is defined as "A complaint that has occurred previously and had a corrective or preventative action(s) implemented, then occurred after implementation of the action(s)." Your firm did not conduct a thorough investigation for the multiple number of complaints reported for the same lot and the high number of complaints reported for the same defect for the same product manufactured at the firm. For example: 1. Complaint #413054 on 07 Sep 2021, product (b)(4) lot# (b)(4) 2. Complaint #339767 on 06 Apr 2021, product (b)(4) lot# (b)(4) D. Complaints were not always classified according to your SOP-03-01-024, titled Customer Complaints, for classification of complaints: Critical, Major, and Minor. For example, On 30 Oct 2020, a Customer Complaint #272397 reported an empty (b)(4) of product (b)(4). Your firm classified this customer complaint as a Major complaint rather than a Critical complaint.

  3. 3

    Missing internal defect control limits

    Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Specifically, Internal defect control limits were not established for the (b)(4) Measurement System (b)(4) inspection process. This was noted during the review of the following batches: Product (b)(4) lot# (b)(4) inspection on 11 Dec 2019 Product (b)(4) lot# (b)(4) inspection on 12 Jul 2019 and 12 Aug 2019.

  4. 4

    Inadequate AQL sampling and acceptance criteria

    Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet appropriate statistical quality control criteria as a condition for their approval and release. Specifically, A-SOP-03-04-001, Performance of AQL for Parenteral Inspections, states AQL sampling should be a representation of the entire batch. "During (b)(4) Inspection with (b)(4) (System 2440), if AQL fails for an equipment related issue that can be corrected, stopping to segregate materials and then restarting the AQL is the proper course. A Tightened AQL will be performed on segregated materials. If the issue is not able to be corrected by an adjustment to the (b)(4), the AQL will be completed in its entirety to satisfy this requirement, and a Focused Tightened AQL on the batch will be completed when appropriate." Your firm does not take AQL samples that are reflective of the entire batch. Your firm has had approximately (b)(4) drug products which exceeded AQL limits during visual inspection since 9/1/2020. It is in your procedure, A-SOP-03-04-001, to segregate product that has exceeded AQL at the time of inspection and reinspect the segregated portion under a tightened inspection. The remaining, uninspected, portion is then continued to be visually inspected under normal AQL inspection levels with a new batch size created. AQL inspection is performed while visual inspection is in progress, however, there is no documentation for when AQL samples are inspected. There is also no documentation for which (b)(4) have been sampled. According to the AQL procedure, the samples should represent "good saturation" throughout the batch, however this is not verifiable based on current AQL documentation. Segregation of the AQL portion that exceeded limits relies on immediate action from the QA inspector to hold and segregate those AQL portions. In addition, the uninspected portion is not included in the portion exceeding the AQL limit. The uninspected portion should be considered a part of the total AQL population. For example: Lot (b)(4) for product (b)(4) exceeded AQL for critical defects. This lot was run on the (b)(4) and segregated at the time of exceeding AQL limits, according to DEV 483844. The defect was determined to be a crack in the neck of the vial. The segregated portion was reinspected on a tightened AQL on the (b)(4). The remaining, uninspected, portion was allowed to continue normal AQL inspection levels on the (b)(4) with a new batch size determined from the remaining population.

  5. 5

    Inadequate automated inspection equipment qualification

    Equipment used in the manufacturing of a drug product is not of appropriate design to facilitate operations for its intended use. A. 1. Your firm did not demonstrate that the (b)(4) is better than or equivalent to (b)(4) inspection. Your firm did not consider individual defect vial performance when establishing acceptance criteria during (b)(4) ((b)(4) System 2414) Performance Qualification (PQ) (b)(4) mL, VPQ-258-000-0002-P, recipe (b)(4) Rev 1.0. 2. Additionally, instances where defects were not caught by the (b)(4) were not evaluated because they were averaged out based on the acceptance criteria in part A. Your firm runs each defect type and size on the (b)(4) in (b)(4). According to your Senior Manager of Engineering, the particulates could no longer be free floating in the vial for a number of reasons such as being stuck in the stopper or on the vial wall. The (b)(4) qualification documents also did not demonstrate that the (b)(4) inspection method could resuspend the particulates in the product once they became undetectable/stuck on the vial wall. 3. Your firm did not evaluate extrinsic particulate, such as hair, detectability during qualification of the (b)(4) (System 2440) for recipe (b)(4)-304 V.9. Extrinsic Particulate Matter is a (b)(4) Critical Defect that is checked during visual inspection. B. 1. The product used for your (b)(4) inspection base line study (Knapp study) did not have the same properties as the product used during (b)(4) qualification. Your firm used a surrogate product for particulate analysis performed during the Knapp study A-DSR-18-01-091 as a baseline to qualify recipe (b)(4) Rev 1.1 on (b)(4) (System 2405). The surrogate product attributes are not detailed in the summary or executed report for the Knapp study. 2. Your firm does not have a program to re-evaluate performance qualifications based on continued process improvements. For example, your firm has implemented a test case for gray zone evaluation for new recipe performance qualifications. Your firm also now performs confidence interval calculations for acceptance criteria of (b)(4) Comparison to (b)(4) Inspection Baseline. These recently implemented test cases have not been retroactively applied to previously qualified recipes to assure they are still in a qualified state. C. Your firm has an ongoing issue of (b)(4) integrity issues that are involved in low and high-risk aseptic interventions during the aseptic filling of sterile drugs. Your firm performed a Deviation Trending Investigation for Building (b)(4) on February 9, 2022 and determined the root cause to be the (b)(4) material was not robust enough to maintain integrity during use. Your firm initiated corrective action to remediate the issue to related (b)(4) integrity by opening a change control to switch to a (b)(4) mils thicker (b)(4) from the same (b)(4) manufacture. Your firm has since cancelled that change control and as of the current establishment inspection your firm is still using the original (b)(4) that continue to experience many integrity issues.

  6. 6

    Inadequate aseptic procedures airflow and monitoring

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, or followed. A. The airflow studies demonstrate a number of instances that document a lack of successfully meeting the acceptance criteria. For example, A-VPQ-00178-S-VL-070MAR21 Vial Filling (b)(4) (System 3400) Static and Dynamic Airflow Visualization Study Summary Report, v0, dated 5/10/21 establishes the acceptance criteria for the airflow visualization studies as in part, (b)(4) (b)(4). The March 2021 airflow studies show discrepancies which do not meet the acceptance criteria, for example, * there is no smoke over many of the manual activities to determine that the manual operations do not create/generate air eddies or air turbulence; * there are numerous instances where there has been no smoke evaluations performed for the operators gloved hands and forearms; * the smoke nozzle is not positioned in such a manner to capture the airflow when personnel perform the manual operations; * the videos do not include an evaluation of the fill equipment & fill (b)(4) to determine that the equipment configuration does not negatively impact the unidirectional airflow; * due to the angle of the camera unable to observe smoke over the manual operations; * no visible smoke can be observed during various manual operations; there are numerous instances when equipment and/or personnel hands & arms block the view, which precludes the company from performing an evaluation of the unidirectional airflow. These discrepancies potentially affect the other vial and filling lines used to aseptically fill drug and biologic products. B. Adequate justification could not be provided for not performing contact plating of all (b)(4) (b)(4) used during the aseptic filling of sterile product. Instead, environmental monitoring of (b)(4) is based on the frequency of typical batch usage and what can be performed at that (b)(4) port. Usage is based on A-SOP-21-01-054, Drug Product (b)(4) Program, v16, dated 6/20/22 which specifies typical batch usage as low, medium or high. Only high usage (b)(4) and (b)(4) used to perform high risk interventions are monitored at the (b)(4) of an aseptic fill. No supporting data could be provided to justify the typical batch usage categories. Only the use of (b)(4) used to perform high risk interventions is documented. The firm has (b)(4) vial filling lines, (b)(4) filling lines and (b)(4) flexi-filling line. C. The rational to only require Quality oversight of high-risk interventions during aseptic filling is inadequate. Documentation only supports Quality oversite during high-risk interventions.

  7. 7

    Inadequate routine equipment checking program

    Routine checking of equipment is not performed according to a written program designed to assure proper performance. Specifically, A. Your firm does not assure that the (b)(4) is working within expected parameters during set up for a run. Your firm uses a challenge set with gross defects only prior to running in order to check (b)(4) operability. The challenge set does not include vials that are at a known visible range of detection. According to A-SOP-22-03-014, (b)(4) Vial Inspection Test Set Composition and Handling, "The intention of the challenge is to verify (b)(4) operability ((b)(4) mechanism, and general (b)(4) functionality) is correct." B. Your firm did not qualify the (b)(4) Vial Inspection (b)(4) System CL 145) (b)(4) (b)(4) speed during any qualification activities. Your procedure, A-SOP-22-05-009, (b)(4) Process Operational Flow, states "Verify vials have at least (b)(4) in inspection zone" during set up. This verification is not documented, and no data has been generated during qualification to show that all vial sizes will perform (b)(4) during inspection. (b)(4) speeds are the only parameter verified during set up. The firm uses vial sizes ranging from (b)(4) mL on the (b)(4) inspection system.

  8. 8

    Inadequate visual inspector qualification procedures

    Your firm failed to establish and follow adequate control procedures to monitor the output and to validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. The following discrepancies were noted during the review of visual inspector qualification for aseptic filling: A. Although included in the emulsion visual inspection kit, visual inspectors for emulsion products are not qualified to detect Major A defects. This category contains fibers or intrinsic particulate matter. B. The emulsion visual inspection kits do not represent extrinsic particulate matter. C. A visual inspection kit does not exist for (b)(4) vials. Instead, the inspectors train on the aqueous glass kit. The aqueous kit does not contain the following defects specific to (b)(4) vials: (b)(4). D. Per A-SOP-22-01-009, titled (b)(4) Inspection Test Set Composition and Handling, version 13, dated 25 Jan 2021, "all defects will be (b)(4) during the (b)(4) qualification PBA so that over the course of the (b) required passes the inspector has had an example of all defects listed in A-WI-03-04-001-002 Parenteral Inspection Defect Criteria List". This procedure was not followed during the initial qualification of operator (b)(6), performed on 20 and 21 Jul 2021 and the emulsion qualification of (b)(6) on March 8, 2021. E. You cannot confirm through documentation the inspection times during the execution of visual inspection qualification tests is representative of routine visual inspections.

  9. 9

    Non-representative in-process particle sampling

    In-process samples are not representative. Specifically, There is no scientific justification for not performing particles testing on routinely inspected product. Batches of aseptically filled (b)(4) are inspected by (b)(4). The particulate defects are rejected and the "ejects" are run through the (b)(4) (b)(4) for additional inspection. Instead of performing destructive particles testing on the good vials remaining after the (b)(4) inspection, (b)(4) vials are sampled from the batch prior to being visually inspected by this process and rather are inspected by ISC (Inspection Sample Control) personnel. The samples undergoing destructive particles testing are not fully representative of routine production.

  10. 10

    Inadequate aseptic process validation and media fills

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. A. The material (b)(4) for vial filler (b)(4) has not been qualified for LIMS labels. Deviation 493708 dated 2/25/22 was initiated due to action levels being obtained on an (b)(4) in vial line (b) between the (b)(4) and the conveyor. The root cause determined the validation requirements for layout, configuration and/or label orientation for LIMS labels in the (b)(4) are not qualified. The risk assessment for batch impact determined the labels achieve a (b)(4) log reduction (decontamination), and not the preferred (b)(4) log reduction. Action 552193 was initiated 6/28/22, to update A-WI-21-06-005-02 to label contact plates in the (b)(4) with marker instead of LIMS labels. The (b)(4) is still used to pass through LIMS labels. This fill line is not dedicated and can be used to aseptically fill both biologic and drug products. B. There is no assurance that media fills are representative of routine production as media fills are not performed under the most challenging or stressful conditions and do not simulate your production process. 1. Trending of interventions during sterile manufacturing does not take into consideration packaging configuration (i.e., vial size and run speed). Instead, trending of interventions is performed by averaging all interventions from all batches run on a particular line. Vial sizes could range from (b)(4) to (b)(4) mls. 2. Adequate scientific justification was not provided for grouping interventions. TEC-000-300-068 Drug Product Manufacturing Media Fill Interventions Rational and Risk Assessment, v7, dated 2/22/22, states all interventions have been grouped based on the required steps to perform each intervention. The intervention with the highest risk was chosen to represent all interventions in that grouping during the media fills. The document equates clearing stopper jam in bowl or (b)(4) as the same risk level as stopper/seal addition with or without (b)(4) port). 3. Multiple line speeds are addressed within a single media fill batch (i.e., (b)(4) (b)(4)%). This is significant as there is no assurance that the media fills performed are representative of routine manufacturing. The Senior Manager of Value Steam stated the intention during production is to run at (b)(4)%.

  11. 11

    Failure to review quality standards and supplier complaints

    Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures. Your firm did not establish criteria during supplier qualification and requalification based on recurring supplier complaints in A-SOP-03-03-003, Supplier Qualification. In addition, your firm has not been tracking and trending supplier complaint reports when a complaint is filed to the supplier. Records are opened for many months before tracking is completed. For example: Record# 533727, dated 5/15/2022, regarding (b)(4) assembly. Record# 565406, dated 5/20/2022, regarding (b)(4) assembly. Record# 566111, dated 05/12/2022, regarding sterile bag used for sterile filling operations.

  12. 12

    Inadequate laboratory controls and test procedures

    Your firm failed to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity. A. The verification of method AM-(b)(4) 100-018 Supplemental Destructive Visual Inspection for Visible Particulates of Client (b)(4) Drug Product Samples, v1, on 7/12/22, demonstrated the analyst could execute the method. The verification did not show the method or the analyst's ability to detect particles. B. A-SOP-09-01-061, (b)(4) Inspection of Media Filled Vials, v9, dated 12/13/21 states to (b)(4) (b)(4) the containers for approximately (b)(4) prior to inspection to suspend any potential microbial growth. (b)(4) the vial prior to initial review could potentially disperse the microbial film on the surface of the media if it existed. C. On 8/1/22 during the walk-through inspection of the Microbial Testing Laboratory, air bubbles were observed between the (b)(4) filter and the (b)(4) plate. Four out of (b)(4) water system sampling plates corresponding to samples collected on 7/19-20/22 were observed having bubbles. Inadequate contact between the filter and the (b)(4) might compromise microbial recovery. The impact of the bubbles on any microbial film on the surface of the media was not provided. D. During the walk-through inspection of the Microbial Testing Laboratory, a discrepancy on CFU counts was noted ((b)(4) CFUs on 7/25/22, (b)(4) CFUs on 8/1/22). There was no evidence that the reviewer contacted management when the discrepancy was noted. A-SOP-09-01-039, Counting and Reporting Counts of Microbial Plates, v7, effective 12/27/21 states in section 2.1, "When reviewing microbial plates, if the reviewer count differs from that of the original count, then the review must take place within (b)(4) of the original count to change the count or be changed at management discretion". This may impact the original count, and the discrepancy is not documented, and management may not be notified. E. Full reconciliation of injections performed in the quality control laboratory is not performed. The analysts are trained to choose between normal, don't process or don't process or report. A-SOP-09-06-180, Use of BLM Empower 3 Chromatography Data System, does not address these choices. If 'don't process or report' is chosen, these chromatograms are not processed and are not reviewed.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3005949964, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.