Skip to content

Protherics UK Limited

Blaenwaun, Llandysul, United Kingdom

FEI 3001417487DUNS 536591589

FDA has 8 inspections on file for Protherics UK Limited in Llandysul, United Kingdom (FEI 3001417487), from 2009 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant is BTG International Inc (D-U-N-S 617382395).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
8, 2009–2024
0 OAI · 8 VAI · 0 NAI
Inspections with 483 observations shown
2 of 8
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
2 requests, latest Jul 15, 2025
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsPosted 483 · 1 observation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Incomplete mold investigation in storage room

      Your firm has not fully investigated or assessed the impact of finding various molds in a (b)(4) room in which manufacturing materials (used for manufacturing of (b)(4) and (b)(4)) and stability samples are held. From March 2023 to April 2024, five quality investigations were initiated to address molds in (b)(4) room of a (b)(4) and include: #70445; #73010; #73044; DEV-00267; and DEV-00331. These investigations were generated in accordance with procedure (b)(4)-SOP-()-000015, Control of Quality Events and Corrective and Preventive Actions, Ver 21, 23 & 23, which allow for such actions as additional monitoring activities (e.g., (b)(4)) and requires the use of a root cause investigation (which would allow for the expansion of the scope of investigation). Although your firm initiated various corrective actions (CAPAs), the following was revealed during this inspection: a) Your firm did not initiate investigative environmental monitoring and sampling in manufacturing areas of building [illegible] to detect for mold contamination beyond routine EM monitoring to address, for example, routes or pathways of supply items which were put at risk by being exposed to molds in (b)(4) room (b)(4). Note that supply items undergo a cleaning/disinfection regimen before going into controlled areas but given the potential for cross contamination and movement of mold spores, routine EM might not be sufficient to capture the extent of, for example, emerging mold risks. b) A primary cause of the molds occurring in (b)(4) room (b)(4) was due to the (b)(4) in a (b)(4) (b)(4) (Deviation [illegible] 00267, April 2024) of two (b)(4) units (b)(4), due to a [illegible]. Investigation of other similar (b)(4) units which contain a (b)(4) was not done to assess for impacts of the (b)(4) which may need to be, for example, inspected and cleaned frequently or replaced by (b)(4) units that are designed with less risk. (b)(4) units with similar designs include: i. (b)(4) unit in (b)(4) (b)(4) in Building (b)(4) in Building (b)(4) ii. Unit (b)(4) - Room (b)(4) (b)(4) iii. Unit (b)(4) - Room in Building (b)(4) (b)(4) iv. Unit (b)(4) - Room (b)(4) in Building (b)(4)

  2. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsPosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Deficient QC testing procedures and controls

      QC testing procedures are deficient. Specifically, A. There is a lack of study to support the (b)(4) of sample (b)(4) for endotoxin analysis per (b)(4)-13.160, v7, section 6.12.3. B. (b)(4) media are not being compared to previously tested and approved batch of the same media type. Instead, they are being compared to (b)(4) obtained from (b)(4) per (b)(4) (b)(4)-13.015, v15, section 6.7.1. C. There is a lack of (b)(4) under (b)(4) conditions despite (b)(4) qualification requires the assessment of a (b)(4) recovery per (b)(4)-13.002, v7, section 2. D. (b)(4) prepared (b)(4) cultures are not qualified prior to release for use. (b)(4) cultures are being used as (b)(4) for (b)(4) and (b)(4). E. Drug samples are not (b)(4) in analytical sequences to verify (b)(4) control. A (b)(4) is analyzed (b)(4) sample and does not confirm that the (b)(4) instrument is in a calibrated state upon the completion of the analysis. As a result, drug product results were invalidated and retested, due to a (b)(4) calibration test failure. For example, i). Quality Event 55795 - The (b)(4) calibration for the Quality Control (b)(4) was conducted per SOP (b)(4) entitled, "(b)(4) (b)(4)" on June 29, 2020, and failed the (b)(4) accuracy test during the calibration. Consequently, all CroFab and DigiFab (b)(4) drug product release tests that were performed (b)(4) (b)(4) were invalidated and retested. All sample retests had passing results. F. (b)(4) are not included at the end of analytical sequences to ensure (b)(4) control for the following (b)(4) analyzes. i). 13.059, entitled, "Determination of Drug Product Protein content by (b)(4)" ii). (b)(4) 13.0028, entitled, "Product speciation - (b)(4)" iii) (b)(4)-13.110, entitled, "Measurement of DigiFab biological activity (Potency) & specific content by"

    2. Observation 2

      Deficient facility qualification testing in Grade area

      (b)(4) testing (b)(4) conducted in - Grade (b)(4) area in September 2021 as part of the facility qualification was deficient. Specifically, A. There was a lack of consistent supply of (b)(4) for an adequate assessment of (b)(4) HEPA (b)(4) or the absence of (b)(4) as required per (b)(4)-04.013, v1, section 6.2. B. Aseptic operations carried out during routine processing including worst-case activities which cause the most potential for product contamination were not adequately simulated under dynamic conditions as required per (b)(4)-04.013, v1, section 6.4.

    Show observation 3
    1. Observation 3

      Deficient environmental monitoring system for classified areas

      Classified (b)(4) areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. There is a lack of documented risk based assessments for identifying the environmental monitoring (EM) sample locations. B. (b)(4)-13.009, entitled "Viable Environmental Monitoring Procedures", v27 is deficient in that the above procedures do not define specific EM sample locations when no processing is scheduled.

  3. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  7. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  8. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 15, 2025. Each one asked for a Form 483.

  • Inspection ending Aug 13, 2024VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Apr 24, 2025FDA-FOIA-2025-3689Form 483· 1 of 3 sitesRecords released
  • Inspection ending Jun 23, 2022VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jul 15, 2025FDA-FOIA-2025-8714Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing, analysis
Registration runs through
Dec 31, 2027
Registrant
BTG International IncD-U-N-S 617382395

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3001417487 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3001417487. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.