FDA issued this Form 483 to Front Door Pharmacy, LLC in Houston, Texas (FEI 3012937475) at the end of a drug inspection that ended June 7, 2021. It lists 7 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Mar 22, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jun 7, 2021
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Mar 22, 2024
- 1,019 days after the inspection
The 7 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Blocking first-pass HEPA air flow
Personnel were observed conducting aseptic manipulations or placing equipment/supplies in an area that blocked the movement of first pass air around an open unit, whether before or after it is filled with sterile product. Specifically, during the visual sterile production observation of the finished sterile drug product, P105 (b) (4) (PAP30MG/ PHE1MG/ PGE10MCG), Lot # 051321, Expiry 7/16/21 being performed by the pharmacy PIC, the following conditions were observed: A. Reaching over filled sterile (b) (4) unstopped vials to fill empty vials. B. Placed a tray of empty vials awaiting filling in between the HEPA filter and the vials undergoing (b) (4) - (b) (4)/filling, resulting in an interruption of 1st air for the vials being processed the ISO 5 LAFU.
- 2
Inadequate media fill program
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that prove a challenge to aseptic operations. Specifically, your pharmacy fail to provide an adequate justification for your facility's media fill program in order to simulate aseptic production operations for the worst-case activities and conditions. For example, your firm’s media fill program documented within procedure, Conduct High Risk Media Fill Test, PURE_SOP 3.9.6 Conduct High Risk Media Fill Test fail to represent actual aseptic production practices, which include the stopper placement and affixing the (b) (4) to the vial. Repeat Observation
- 3
Inadequate environmental monitoring
Environmental monitoring was not performed in your aseptic processing areas. Specifically, Environmental Monitoring and measurement frequency of microbiological contamination (viable/non-viable monitoring) of the air in the ISO 5 zone is inadequate. Your pharmacy fail to establish a viable monitoring program during sterile drug production within the ISO 5 LAFU. Additionally, during a review of your pharmacy's cleanroom re-certification for VIABLE Report 1.27.2021, which documents the (b) (4) assessment of air, and Surface contaminates within ISO 7 and ISO 8 Ante-room, fail to include the ISO 5 LAFU.
- 4
Sporicidal agent not validated
The use of sporicidal agents in the cleanrooms and ISO 5 classified aseptic processing area was inadequate. Specifically, your firm failed to validate the sporicidal agent, (b) (4) Sporicidal Disinfectant Cleaner for its intended use within the cleanroom and aseptic production processing area. Repeat Observation
- 5
Poor airflow design / air returns
Your facility design allowed the influx of poor-quality air into a higher classified area. Specifically, your firm air returns are adjacent to your HEPA filters in the ceiling of the ISO (b) (4) 8 Anteroom and ISO 7 Cleanroom used in the production of sterile drugs. Your pharmacy fail to provide records and/or documents (smoke study) in support of adequate air circulation in the prevention of an influx of poor quality air into a higher classified area. Repeat Observation
- 6
Inadequate hazardous drug cleaning/segregation
You produced hazardous drugs without providing adequate segregation, cleaning of work surfaces and cleaning of utensils to prevent cross-contamination. Specifically, your pharmacy produces the non-sterile hazardous drug, Testosterone Cream 100 mg/mL and Estradiol 0.1MG/GM Cream without adequate segregation, deactivation, and adequate cleaning program to prevent cross-contamination. All non-sterile compounded drugs are compounded in the same designated drug production area without adequate cleaning requirements. Your firm's hazardous material SOP, Hazardous Material_4.9.6, Handling Hazardous Material - Pharmacy procedure failed to include cleaning requirements to deactivate hazardous drug products and components. Your pharmacy technician report your firm uses dish (b) (4) detergent to wash and allow to [illegible]. Equipment is wiped using (b) (4) Repeat Observation
- 7
ISO-5 not certified under dynamic conditions
ISO-5 classified areas were not certified under dynamic conditions. Specifically, unidirectional airflow was not verified under operational conditions. Your firm’s clean room re-certification reports tests dated 1/27/2021, 8/5/2020, 2/12/2020, and 8/15/2019 were documented as being performed in dynamic conditions. On 5/24/2021, PIC reported no aseptic production simulation was performed at the time of any of the documented cleanroom and ISO 5 aseptic production processing areas during re-certifications. Repeat Observation
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3012937475, newest first.
- Form 483, March 2019Inspection ended Mar 18, 2019 · Posted Apr 30, 2019OAI
- Form 483, March 2019Inspection ended Mar 18, 2019 · Posted Apr 30, 2019OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.