Front Door Pharmacy, LLC dba Pure Pharmacy Form 483, March 2019

FDA issued this Form 483 to Front Door Pharmacy, LLC dba Pure Pharmacy in Houston, Texas (FEI 3012937475) at the end of a drug inspection that ended March 18, 2019. It lists 11 observations. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Apr 30, 2019. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Mar 18, 2019
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Apr 30, 2019
43 days after the inspection
Facility
FEI 3012937475
Houston, Texas

The 11 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Exposed skin during aseptic processing

    Personnel engaged in aseptic processing were observed with exposed skin. Specifically, on 3/6/2019, your pharmacist was observed with exposed skin while compounding the sterile produced drug, P-105 Lot# 030719@1 BUD 09/07/19, Qty. [illegible] vials. Your pharmacist's sterile gloves failed to extend over the sleeves of the gown worn.

  2. 2

    Media-fill program inadequate

    Media fills were not performed that closely simulate, as appropriate, worst-case activities and conditions that prove a challenge to aseptic operations. Specifically, your media fill program fails to simulate activities and conditions within your firm's aseptic processing operations. For example, your firm's media fill aseptically simulates manipulating [illegible] compound batch size is [illegible] vials for the compounded [illegible].

  3. 3

    Gloved hands touched non-ISO surfaces

    Personnel touched equipment or other surfaces located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing. Specifically, on 3/7/2019 during the aseptic processing of P-105 Lot# 030719@1 BUD 09/07/19, Qty. [illegible] vials, personnel performed a task in the ISO 7 cleanroom/processing area multiple times without re-sanitizing gloves. The skin of the pharmacist's hands was completely exposed while working in the ISO 5 hood.

  4. 4

    Equipment/materials not disinfected

    Equipment and materials or supplies were not disinfected prior to entering the aseptic process. Specifically, on 3/6/2019 the following conditions were observed: A. While compounding the sterile drug, your firm's pharmacist failed to disinfect non-sterile drug components, Phentolamine Mesylate USP, Mannitol USP, and Papaverine HCL, prior to removal from where weighed and staged on the stainless-steel table in ISO 8 anteroom and prior to entry into the ISO 5 aseptic processing area. B. The [redacted] mixer was observed with foreign residue on its outer surface. Your firm's pharmacist placed the mixer into the aseptic compounding area without disinfecting it. C. Your firm's stool, in the ISO 7 cleanroom, is covered with a material which cannot be adequately disinfected.

  5. 5

    Non-sterile / unlabeled disinfectants used

    Disinfecting agents used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, your firm pharmacist was observed using an unlabeled bottle of non-sterile [redacted] to disinfect the ISO 5 hood aseptic processing surfaces. Unlabeled bottles of non-sterile [redacted] were found in the pharmacy's ISO 8 anteroom and ISO 7 cleanroom. Your firm failed to provide records and/or surface disinfectant/decontaminant documentation for use in the clean room and aseptic processing area.

  6. 6

    Unvalidated sporicidal use

    The use of sporicidal agents in the cleanrooms and ISO 5 classified aseptic processing area was inadequate. Specifically, your firm failed to validate the use of [redacted] cleaner as a sporicidal agent used in your firm's cleaning program.

  7. 7

    Poor quality air influx from design

    Your facility design allowed the influx of poor quality air into a higher classified area. Specifically, your firm air returns are adjacent to your HEPA filters in the ceiling and ISO 7 cleanroom used in the production. Your firm failed to provide documents (smoke study) in support of adequate air circulation in the prevention of an influx of poor quality air into a higher classified area.

  8. 8

    Incubator/environmental control inadequate

    Laboratory test equipment used in the preparation and testing of collected samples are inadequate. Specifically, your firm uses a [redacted model] for the incubation of collected media-fills. The unit fails to have adequate temperature and related humidity controls to perform and control these environmental conditions.

  9. 9

    Hazardous drugs without proper segregation

    You produced hazardous drugs without providing adequate segregation, deactivation, and cleaning of utensils to prevent cross-contamination. Specifically, your firm produces the non-sterile hazardous drug, Testosterone Cream 100 mg/g, without adequate segregation, deactivation, and adequate cleaning to prevent cross-contamination. All non-sterile compounded drugs are produced in the same designated drug production area without adequate cleaning requirements.

  10. 10

    ISO-5 not certified dynamically

    ISO-5 classified areas were not certified under dynamic conditions. Specifically, unidirectional airflow was not verified under operational conditions. Specifically, your firm's clean room re-certification tests dated [redacted] were documented as being performed while the pharmacy contract clean room certifier reported that he does not recertify the clean room while pharmacy is performing media fills and/or compounding actual sterile drug products. He reported no, he simulates motion in the clean room compounding area and documents as being in a dynamic state. The firm reported no media fills and/or drug compounding during certifications.

  11. 11

    Particle-generating, hard-to-clean surfaces

    The ISO-classified areas have difficult-to-clean, particle-generating surfaces. Specifically, during a walk-through on 2/25/2019, foreign particulate matter was observed on top of [redacted] which was not in service. Foreign particulate matter was observed in the ISO 7 production area adjacent to the ISO 5 hood. The firm failed to prevent particle generation or provide adequate cleaning for visibly dirty equipment or surfaces.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterJul 1, 2020CDER · 471 days after this inspection ended

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3012937475, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.