Skip to content

Fujifilm Diosynth Biotechnologies USA Inc.

6051 George Watts Hill Dr, 6040 George Watts Hill Drive, Research Triangle Park, North Carolina, United States

FEI 3000718852DUNS 099312980

Company: FUJIFILM Corporation · Linked by exact D-U-N-S match (713565195) in FDA registration data

FDA has 6 inspections on file for Fujifilm Diosynth Biotechnologies USA Inc. in Research Triangle Park, North Carolina (FEI 3000718852), from 2010 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below. One of the six FOIA requests for this site has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant, FUJIFILM Corporation (D-U-N-S 713565195), has registered 5 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
6, 2010–2026
0 OAI · 2 VAI · 4 NAI
Inspections with 483 observations shown
2 of 6
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
6 requests, latest May 8, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate contamination controls

      Facility design and procedural controls for manufacturing drug substance intended for commercial distribution do not provide adequate assurance against microbial contamination and cross-contamination risks in the manufacturing suite at your Fujifilm Diosynth Biotechnologies USA Durham facility. Specifically, A. Your firm has failed to establish a facility cleaning and sanitization program that effectively prevents microbial contamination in drug substance manufacturing areas and products. Despite the repeated isolation of spore-forming organisms including approximately 80 bacterial isolates and approximately 6 mold isolates from classified air spaces between January 2025 and the present and the rejection of at least [illegible] batches due to contamination with these organisms since 2024, your firm continues drug substance manufacturing intended for sterile injectable production without determining root cause or implementing corrective and preventive actions. In several investigations launched for these recoveries, your firm's documented position that "there is no impact to process performance or product quality" is unacceptable and demonstrates a fundamental failure to recognize the serious contamination risks posed to sterile drug products. B. You do not perform routine monitoring of your ISO-5 conditions. Currently, environmental monitoring (EM) of these conditions is limited to major activities such as (b) (4), passaging of (b) (4), and bulk fill operations. You do not have EM data to support "at rest" conditions. Furthermore, you have not performed a risk assessment or study to verify that your EM locations used for current sampling of these environments are suitable for collecting data representative of the actual conditions. Additionally, you do not have scientific rationale to demonstrate that settle plates used for passive air monitoring of these areas can recover micro-organisms for your established maximum exposure time of (b) (4). C. Your firm lacks scientific justification for failing to ensure that all cleaning agents used in controlled environments are purchased sterile. For example, you have not ensured that (b) (4) which is used as (b) (4) disinfectant for (b) (4) application in these areas to include ISO-5 environments is sterile. Drug substances produced in your facility are intended for the manufacture of parenteral drug products.

    2. Observation 2

      Insufficient investigation of contamination

      Your unexplained discrepancies associated with your processes are not thoroughly investigated. Specifically, A. You opened several investigations after recovering mold in your processing rooms, supporting rooms, raw materials, and product in various stages of your process. From our review, we concluded the following were not thoroughly investigated: Reason for Investigation Mold Recovered Reason for Inadequate Number Investigation PR Filamentous mold recovery in | Talaromyces rugulosus The root cause was not identified. 386943 | (b) (4) Viral(b) (4) | pool of Batch was released. [illegible] PR Mold in (b) (4) viable air | Cladosporium allicinum/ No root cause was identified, and 327905 | sites. cladosporioides/ cucumerinum/ no remediation was performed. herbarum/ macrocarpum/ phaenocomae/ ramotenellum PR Mold recovery in batch Aureobasidium melanogenum No root cause identified. 380876 | (b) (4) during (b) (4) inadequate corrective actions. Post Hold. Batch was ultimately rejected. PR Mold recovery in batch Paenibacillus glucanolyticus/ No root cause identified, no 353881 | (b)(4) during (b) (4) Purpureocillium lilacinum. identified impact to product or [b] [illegible] process, and inadequate corrective actions. Batch was ultimately rejected. B. Your firm does not investigate all instances of spore-forming bacteria recovered in your drug substance samples. Since January 2025, there have been at least 26 bacterial spore-forming recoveries found in your drug substance samples at different stages of the manufacturing process. Your Senior Director of Microbiology stated that these recoveries are not investigated because the firm's written procedure, SOP-01732 version 33 'Investigation of Invalid, Out of Specification and Atypical Test Results,' does not require investigation of these findings. Your firm has not determined the source or route of entry for these spore-forming organisms into the manufacturing process. C. On 10/14/2025, your firm recovered Ralstonia pickettii, a gram-negative biofilm forming organism in the (b) (4) system ((b) (4)). For remediation, you replaced (b) (4) on 9 sample ports and (b) (4) the system. Your quality unit failed to evaluate whether this system continues to operate in a validated state following these modifications. Furthermore, you have not conducted a risk assessment to support that your bioburden sampling for (b) (4) (b) (4) post these corrective actions is adequate to verify complete biofilm removal. Per your Associate Director of Facilities, this (b) (4) is used as starting material for the (b) (4) system, cleaning of equipment/utensils, upstream processing, and as starting material for the (b) (4). D. On 03/09/2024, your firm recovered Ralstonia pickettii, a gram-negative biofilm forming organism in your (b) (4) system. You determined there was no impact to your (b) (4) system since the (b) (4) was resampled on 03/11/2024 and had passing results. No additional actions were taken other than trending your (b) (4) testing for (b) (4). You do not have evidence that your sanitization process is eliminating biofilm or biofilm forming organism. Per your Associate Director of Facilities, this (b) (4) is used for downstream processing and equipment cleaning. E. On 12/20/2023, you recovered Burkholderia lata (B. cepacia complex), a gram-negative biofilm forming organism in your (b) (4) system. You determined there was no impact to your (b) (4) system since all other samples collected that day obtained passing results. You trended these samples collected (b) (4) for (b) (4) and trended other similar investigations. However, no additional actions were taken, and you do not have evidence that your sanitization process is eliminating biofilm or biofilm forming organism. Per your Associate Director of Facilities, this (b) (4) is used for downstream processing and equipment cleaning.

    Show observations 3 to 4
    1. Observation 3

      Inadequate testing limits for assemblies

      Your procedure for testing (b) (4) after use in your drug substance processing is inadequate in that it does not limit of times it could be tested. Specifically, your written procedure for testing process (b) (4), SOP-01444, Use and (b) (4) Testing of Solution and (b) (4) Assemblies in the Manufacturing and Facilities, Version 22, has a limit of (b) (4) (b) (4) tests before contacting the area manager. Per this procedure, the area manager can approve additional (non-defined) (b) (4) testing. This procedure is inadequate to detect (b) (4) failures.

    2. Observation 4

      Unsuitable microbiological methods

      You have not ensured your microbiological methods are suitable for your operations. You have not performed a risk assessment or evaluation to determine if your current bioburden methods of testing for both total aerobic microbial counts (TAMC) and total yeast microbial counts (TYMC) using both (b) (4) and (b) (4) media is suitable for recovering organisms that could potentially pose a risk to patients in light of the spore forming isolates (bacteria and mold) routinely recovered in your facility. Per your Sr. Quality Director, your organization "does not have a tolerance for spore-formers" and further stated "mold is bad." Your current process does not screen for specific organisms. Per your Sr. Scientist of Microbiology, there is no trigger to evaluate the capability of the methods once it's approved for use.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      No cross-contamination risk assessments

      There are no comprehensive risk assessments conducted at this multiproduct facility to justify the containment strategy and controls of manufacturing (b) (4) products using microbial and cell culture processes to prevent cross-contamination. Specifically, a. A formal risk assessment evaluating the cross-contamination risks of (b) (4) drug substance by other (b) (4) products (b) (4) PDE = (b) µg/day, (b) (4): PDE = (b) µg/day, and (b) (4): PDE = (b) µg/day) manufactured in the same areas with shared product contact equipment has not been documented. b. The downstream purification areas and product contact equipment for manufacture of (b) (4) drug substance is shared with a (b) (4) product using a (b) (4) expression system (Molecule (b)). There is no formal risk assessment conducted evaluating any potential viral cross-contamination risks. (b) batch# (b) (4) (a post-PPQ run) was manufactured in the same suite after a campaign of (b) batches of Molecule (b) was manufactured. c. Molecule (b) is classified as a Band C (b) (4) product) for cleaning, per RA-389.01, Revision 01 to Upstream and Downstream Risk Assessment for Facility and Safety Risk Assessment for Band C Molecule (b). However, the same molecule is classified as Cleaning Band D (non-(b) (4) product) based on the List of FDBU Programs for CY 2020 2021 provided to the inspection team during the inspection. d. (b) (4) was assessed to have a PDE of (b) µg/day and deemed a Band D (non (b) (4) product. However, the PDE determination is not scientifically justified. There was no adequate risk assessment conducted evaluating cross-contamination risks for other products manufactured in the same manufacturing areas using shared product contact equipment.

    2. Observation 2

      Manufacturing process not monitored controlled

      The (b) (4) manufacturing process is not adequately monitored and/or controlled to ensure the quality of the (b) (4) drug substance is not adversely affected. Specifically, a. On 04/15/2021, during observation of (b) (4) batch# (b) (4) step (b) (4) temperature of the (b) (4) stored in SUM-(b) (4) L was at (b) °C. On 04/21/2021, during observation of (b) (4) batch# (b) (4), Bulk Fill, temperature of (b) (4) Retentate stored in SUM-5010 was at (b) °C. However, it is stated in (b) (4), temperature during intermediate hold for (b) (4) and (b) (4) Retentate is at (b) °C. Product temperature is not recorded or monitored throughout the process to ensure it is within the established limits. b. Discoloration was observed in the (b)-4018 (b) (4). The (b) (4) is shared with other products. The source of the discoloration is unknown. The (b) (4) was used for (b) (4) batch# (b) (4) (b) (4) step. SOPs and Work Instructions related to (b) (4) procedures do not include (b) (4) visual assessment after (b) (4). c. A crevice of approximately 3 inches wide and 1 inch in height was observed under the seal within the (b) (4) in (b) (4)-4019. The (b) (4) had been used for (b) (4) batch# (b) (4) and going to be used for (b) (4) batch# (b) (4) step. SOPs and Work Instructions related to (b) (4) procedures do not include (b) (4) visual assessment after (b) (4). d. Written procedures for manufacturing process are inadequate. On 04/15/2021, during observation of (b) (4) batch# (b) (4) step in Purification (Rm (b) (4)), employees were observed to install an additional valve to remove excess air from the hose connecting the SUM-(b) (4) L and the (b) (4). Installation of the valve to remove excess air is not specified in the batch record for this unit operation.

    Show observations 3 to 10
    1. Observation 3

      Material management procedures inadequate

      Procedures of material management systems are not followed or are inadequate. Specifically, a. Four (4) vials of (b) working cell bank (WCB) are unaccounted for in the PAS-X system. On July 17, 2020, as per FDBU-SOP-0358: Requesting Shipment, Acceptance, Receipt, Storage, Handling, Maintenance, and Shipping of Cell Banks, Revision 25, Effective Date: 10 July 2020, warehouse personnel completed a move transaction in SAP of (b) (4) WCB vials. Due to a damage to vial caps, additional 4 vials of WCB were obtained. Out of the total of (b) (4) vials, (b) (4) were used to inoculate (b) (4) shake flasks and 4 vials were discarded. However, the discard of 4 WCB vials not used during product manufacture was not recorded in PAS-X. b. Expired materials were found in the SAP system in the warehouse. Some materials were expired more than 12 months ago. FDBU-SOP-0349: Handling of Rejected and Expired Raw Materials and Consumables, Revision 11, Effective Date: 27 February 2018 does not specify the time requirement for the expired product disposal. c. An error message of "Power Failure" was observed on the Cryofreezer FZ-0439N used for (b) (4) (b) (4) WCB storage. The power failure occurred on 04/11/2021 and the error message had not been cleared on 04/14/2021. The FDBU-SOP-0255: BMS and DCS Alarm Response and Notification, Revision 15, Effective Date 18 December, 2020 is not clear who is responsible for clearing the alarm.

    2. Observation 4

      Inadequate cleaning procedures for shared equipment

      You failed to establish adequate cleaning and sanitization procedures for non-dedicated product contact equipment at this multiproduct manufacturing facility to prevent cross-contamination. Specifically, a. FDBU-SOP-0388: Changeover of Processing Equipment and Manufacturing Areas, Revision 32, Effective Date: 08 Nov. 2019 defines product contact equipment as any surface that comes into direct physical contact with product proteins or a product intermediate. Shake flasks, fermenters and bioreactors used for inoculation, (b) (4), or production of cultures that do not secret the product or the product intermediate directly into the media are not considered as product contact equipment. No swab samples were taken to demonstrate adequate cleaning. b. FDBU-SOP-0388: Changeover of Processing Equipment and Manufacturing Areas, version 32, effective date: 08 Nov. 2019 and FDBU-SOP-0462: Cleaning Program for Process Equipment, Revision 09, Effective Date: 02 Apr 2020 allow equipment recleaning if a swab sample result failed to meet the acceptance criteria without conducting a root cause investigation. An investigation is only required if the swab sample result failed after the recleaning. c. TOC recovery and degradation studies documented in CV218Recovery.00: Evaluation of Soil Recovery of Molecule (b) Approved 03/20/2019, were inadequate. On 04/16/2021, Scientist II, Bioassay Development with initials (b) (6) stated that there is no defined procedure for drying of the soiled coupons used in recovery study. The drying condition was unrepresentative of dirty hold times. In addition, the degradation study demonstrated that significant amounts of (b) (4) remained undegraded after (b) (4) treatment for (b) (4). There is no assurance that the cleaning procedures can effectively eliminate (b) (4) activity or toxicity. d. Process (b) (4) Cycles are used for Process Vessels that are deemed for "bioburden control" only. FDBU-SOP-0460: Validation and Re-validation of (b) (4) Procedures and Media Holds, Revision 08, Effective Date 19 Nov 2020, states that there is no requirement to requalify Process (b) (4) Cycles.

    3. Observation 5

      Investigations and CAPA inadequate

      Discrepancies are not fully investigated to identify a root cause and corrective and preventative actions (CAPA) are not adequately implemented to prevent recurrence. Specifically, a. Excursions occurred during product validation are investigated as protocol events under FDBU-SOP-0457: Execution and Review of Qualification and Validation Documents. Section 4.6.7.1.2 states that if there is potential or unknown product impact, QA is consulted for further assessment according to FDBUSOP-0432, Deviation/Event Reporting System. However, no formal investigations were conducted for the following protocol events: i. At least ten (10) Endotoxin testing results did not meet the Endotoxin System Suitability Test. You failed to conduct adequate investigations to identify the root causes. ii. Under Protocol Event for (b) (4) three (3) Endotoxin Out of Specification results for in-process hold time studies were reported (PR206361, PR206365, and PR307208); however, no definitive root causes were identified. The firm concluded that the OOS results were "aberrant values" and the hold time studies were valid. No mediation action was taken. iii. PR189569 was opened for two in-process samples ((b) (4) retentate and (b) (4) Load) failing to filter during bioburden qualification testing. A definitive root cause was not identified but was speculated to be prolonged sample storage at 2-8°C ((b) (4) and (b) (4), respectively). It was concluded that this event has no impact to product or process, without considering that the process hold time of (b) (4) Load is ≤ (b) hr at 2-8°C. On 04/19/2021, Principle Process Scientist/Engineer, Group Lead with initials (b) stated that the two in-process samples had been stored at 2-8°C for over a month before used for bioburden method qualification. b. Events PR180216 and 196559 and deviation PR207669 were opened for excursions of personnel monitoring, in-process sample bioburden, and settle plate monitoring. Organisms recovered were identified to be (b) (4). The firm concluded the organisms were (b) (4) host organism, without considering the possibility of cross-contamination of host organism from other (b) (4) processes.

    4. Observation 6

      Inadequate microbial control of facility

      Microbial control of the facility is inadequate. EM excursions were not investigated for root cause and CAPAS implemented were inadequate to control microbial contamination. Specifically, a. (b) (4) environmental and water monitoring summary reports from 2020 documented 30 events of action level Paenibacillus spp. (mostly P. glucanolyticus) recoveries from 57 monitoring sites, 5 events of alert/action level Burkholderia recoveries from 6 monitoring sites, and 4 events of mold recoveries from 5 monitoring sites. All of the excursions were assessed to be isolated incidents with no product impact. It was not taken into consideration that there may be a recurring, facility-wide microbial contamination. For example, 5 P. glucanolyticus recovery events occurred between 02/22/2020-02/28/2020 from 10 monitoring sites in 4 different production suites including Purification (b) (4), where (b) (4) was manufactured. On 02/18/2020 and 02/19/2020, P. glucanolyticus were recovered from (b) (4) in-process samples ((b) (4) and (b) (4) Load). b. Events PR195075 and PR212557 recorded action level excursions of P. glucanolyticus recoveries from floor monitoring sites (b) (4) (TNTC), (b) (4) ((b) CFU) in Purification suites. The samples were taken within (b) (4) of room cleaning. (b) (4) cleaning of the rooms had been implemented under CAPA PR188746 in response to P. glucanolyticus recoveries in 2019. However, P. glucanolyticus continues to be the most prevalent environmental isolate in the facility. Paenibacillus spp has not been evaluated for disinfectant effectiveness. c. Protocol Event PR195707 describes sub-alert level bioburden recoveries of Paenibacillus glucanolyticus ((b) CFU) and Penicillium rubens ((b) CFU) in (b) (4) Lot (b) (4). (b) (4) is a fungal species that produces penicillin (a beta lactam). A definitive root cause was not found but was attributed to sampling error that introduced contamination from the environment or personnel. It was justified that there was no impact to product or manufacturing because there are multiple (b) (4) steps to remove microbial contamination. However, the firm failed to consider the potential impact of residual P. rubens metabolites, e.g. penicillin, to product quality and patient safety, or the overall impact of fungal contaminations in the facility. d. According to FDBU-STDP-0003, Microbial Control Strategy, Revision 03, Effective 29 Oct 2019, step (b) (4) an action limit of (b) (4) CFU/10 mL is set for in-process samples from upstream processes that occur in ISO 8 environment (fermentation, cell culture, and recovery). On 04/15/2021, when we toured the QC Microbiology Laboratory, QC scientist with initial (b) stated that TNTC for bioburden is defined as > (b) (4) CFU/plate. According to TM-0046288, Bioburden Determination Using Total Aerobic Microbial Count and Total Yeast and Mold Count, Revision 05, Effective 23 Dec 2020, step (b) (4) sample volume less than (b) (4) mL must be directed by the client. There is no assurance that a sample exceeding the action limit can be detected.

    5. Observation 7

      Microbial hold time study inadequate

      Microbial (b) (4) hold time study was not adequately conducted. Specifically, a. Purification (b) (4) have a (b) (4) hold time and may be reused for a different process step within expiry. Connection between (b) (4) holding bag and the (b) (4) is not through an aseptic connection and the (b) (4) hold time study did not simulate the reuse condition. b. Fungal (Fusarium oxysporum) contamination was observed from one of the worst-case (b) (4) used in the (b) (4) hold time study, with (b) CFU/10 mL recovered from (b) (4) sample and TNTC recovered from (b) (4) sample (action limit (b) CFU/10 mL). The study concluded that only the worst-case (b) (4) will have a hold time of (b) (4). All other (b) (4) will have a hold time of (b) (4).

    6. Observation 8

      Written procedures not followed

      Written procedures are not followed by manufacturing employees. Specifically, on 04/15/2021, during observation of (b) (4) batch# (b) (4) step in Purification (Rm (b) (4)), employees were observed to use non-(b) (4) tubes for endotoxin sample storage. FDBU-WI-0154: Work Instructions: Collection of Product Samples from the Manufacturing Area, Revision 06, Effective date: 29 May 2020, step 1.1 dictates that endotoxin testing samples are to be stored in pyrogen-free, (b) (4) capped containers. It was later observed that an employee checked in the samples onto LIMS system with the sampling location as Purification (Rm (b) (4)).

    7. Observation 9

      Lack of electronic data integrity controls

      You failed to establish procedural controls for your electronic data acquisition systems to ensure that your data records are protected from unauthorized manipulation. For example, a. The SoftMax Pro software (version 5.3 GxP) used to analyze in-process and release samples of commercial and non-commercial products in the QC Laboratories, including Endotoxin testing of (b) (4) (b) (4) allows analysts to save, delete, and rename data files outside of the approved file storage location (C:\AnalyticalGroup\SampleTesting). b. Raw data from testing are auto-saved under the directory of C:\AnalyticalGroup\Data. However, technical review of the results and associated audit trail as governed by FDBU-SOP-0301: Data Recording and Review in the GMP Laboratory, Revision 22, effective date: 12 January 2021 is only conducted on the file saved in the C:\AnalyticalGroup\SampleTesting folder by the analyst. There is no data and audit trail review associated with files stored in the raw data folder (C:\AnalyticalGroup\Data).

    8. Observation 10

      Facility design maintenance labeling deficient

      Manufacturing areas and equipment in the facility are not adequately designed, maintained, and labeled. Specifically, during facility walk-throughs conducted during the inspection, we observed the following: a. (b) (4) for processing (b) (4) are stored in the ISO 7 and ISO 8 corridors that limit personnel and material flows in the multiproduct manufacturing areas. b. Multiple Use Status Tags did not have the correct information for manufacturing suites, processing steps and equipment status. For example, i. The manufacturing suite tag to Recovery (b) (4) for (b) (4) had the incorrect Room number ((b) (4)) and process steps ((b) (4)). ii. The Tag for VP-2661 indicated the vessel was "in use" and the content was (b) (4) Load. However, the actual status of the vessel was "not in use". iii. The dates and times on two (b) (4) and a (b) (4) used for in-process testing in Recovery (b) (4) and Purification (b) (4) were incorrect. The Room label on the (b) (4) in Recovery (b) (4) was also incorrect. c. Deteriorated sealant at the ceiling was observed in Fermentation (b) (4) creating a gap that exposed the classified area to unclassified air above the ceiling. d. A gap was observed between the floor and the door of the loading dock in the warehouse, allowing opportunities for pest to come into the facility.

  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Six requests to FDA under the Freedom of Information Act named this site, most recently on May 8, 2026. Each one asked for a Form 483.

  • Inspection ending Mar 27, 2026VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. May 8, 2026FDA-FOIA-2026-4743Form 483· 1 of 5 sitesRecords released
  • Inspection ending Feb 10, 2023

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. Oct 23, 2023FDA-FOIA-2023-9327Form 483Closed
  • Inspection ending Feb 22, 2019

    2 requests. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. Jul 2, 2025FDA-FOIA-2025-8222Form 483Closed
    2. Dec 18, 2023FDA-FOIA-2023-11255Form 483Closed
  • Inspection date not given

    2 requests. None of FDA’s log entries for these requests say records were released.

    1. Jul 12, 2022FDA-FOIA-2022-5024Form 483 + EIR· 1 of 3 sitesNo records found
    2. Sep 21, 2021FDA-FOIA-2021-6262Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing, analysis
Registration runs through
Dec 31, 2027
Registrant
FUJIFILM CorporationD-U-N-S 713565195

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names FUJIFILM Corporation (D-U-N-S 713565195) as the registrant for this site and the 5 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

  • FUJIFILM Diosynth Biotechnologies Denmark ApSHillerod, Denmark · FEI 30063398876 inspections6latestJun 30, 2023VAINone on file
  • FUJIFILM Diosynth Biotechnologies UK LtdBillingham, United Kingdom · FEI 30071825676 inspections6latestMar 17, 2023VAINone on file
  • FujiFilm Diosynth Biotechnologies Texas, LLCCollege Station, Texas · FEI 30119484491 inspection1latestAug 31, 2021VAINone on file
  • FUJIFILM Diosynth Biotechnologies California, Inc.Thousand Oaks, California · FEI 3022537234Registered; no FDA inspection on file
  • FUJIFILM Diosynth Biotechnologies North Carolina, Inc.Holly Springs, North Carolina · FEI 3035478337Registered; no FDA inspection on file

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3000718852 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3000718852. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.