Fujifilm Diosynth Biotechnologies USA Inc. Form 483, March 2026
FDA issued this Form 483 to Fujifilm Diosynth Biotechnologies USA Inc. in Research Triangle Park, North Carolina (FEI 3000718852) at the end of a drug inspection that ended March 27, 2026. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jul 10, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Mar 27, 2026
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jul 10, 2026
- 105 days after the inspection
The 4 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate contamination controls
Facility design and procedural controls for manufacturing drug substance intended for commercial distribution do not provide adequate assurance against microbial contamination and cross-contamination risks in the manufacturing suite at your Fujifilm Diosynth Biotechnologies USA Durham facility. Specifically, A. Your firm has failed to establish a facility cleaning and sanitization program that effectively prevents microbial contamination in drug substance manufacturing areas and products. Despite the repeated isolation of spore-forming organisms including approximately 80 bacterial isolates and approximately 6 mold isolates from classified air spaces between January 2025 and the present and the rejection of at least [illegible] batches due to contamination with these organisms since 2024, your firm continues drug substance manufacturing intended for sterile injectable production without determining root cause or implementing corrective and preventive actions. In several investigations launched for these recoveries, your firm's documented position that "there is no impact to process performance or product quality" is unacceptable and demonstrates a fundamental failure to recognize the serious contamination risks posed to sterile drug products. B. You do not perform routine monitoring of your ISO-5 conditions. Currently, environmental monitoring (EM) of these conditions is limited to major activities such as (b) (4), passaging of (b) (4), and bulk fill operations. You do not have EM data to support "at rest" conditions. Furthermore, you have not performed a risk assessment or study to verify that your EM locations used for current sampling of these environments are suitable for collecting data representative of the actual conditions. Additionally, you do not have scientific rationale to demonstrate that settle plates used for passive air monitoring of these areas can recover micro-organisms for your established maximum exposure time of (b) (4). C. Your firm lacks scientific justification for failing to ensure that all cleaning agents used in controlled environments are purchased sterile. For example, you have not ensured that (b) (4) which is used as (b) (4) disinfectant for (b) (4) application in these areas to include ISO-5 environments is sterile. Drug substances produced in your facility are intended for the manufacture of parenteral drug products.
- 2
Insufficient investigation of contamination
Your unexplained discrepancies associated with your processes are not thoroughly investigated. Specifically, A. You opened several investigations after recovering mold in your processing rooms, supporting rooms, raw materials, and product in various stages of your process. From our review, we concluded the following were not thoroughly investigated: Reason for Investigation Mold Recovered Reason for Inadequate Number Investigation PR Filamentous mold recovery in | Talaromyces rugulosus The root cause was not identified. 386943 | (b) (4) Viral(b) (4) | pool of Batch was released. [illegible] PR Mold in (b) (4) viable air | Cladosporium allicinum/ No root cause was identified, and 327905 | sites. cladosporioides/ cucumerinum/ no remediation was performed. herbarum/ macrocarpum/ phaenocomae/ ramotenellum PR Mold recovery in batch Aureobasidium melanogenum No root cause identified. 380876 | (b) (4) during (b) (4) inadequate corrective actions. Post Hold. Batch was ultimately rejected. PR Mold recovery in batch Paenibacillus glucanolyticus/ No root cause identified, no 353881 | (b)(4) during (b) (4) Purpureocillium lilacinum. identified impact to product or [b] [illegible] process, and inadequate corrective actions. Batch was ultimately rejected. B. Your firm does not investigate all instances of spore-forming bacteria recovered in your drug substance samples. Since January 2025, there have been at least 26 bacterial spore-forming recoveries found in your drug substance samples at different stages of the manufacturing process. Your Senior Director of Microbiology stated that these recoveries are not investigated because the firm's written procedure, SOP-01732 version 33 'Investigation of Invalid, Out of Specification and Atypical Test Results,' does not require investigation of these findings. Your firm has not determined the source or route of entry for these spore-forming organisms into the manufacturing process. C. On 10/14/2025, your firm recovered Ralstonia pickettii, a gram-negative biofilm forming organism in the (b) (4) system ((b) (4)). For remediation, you replaced (b) (4) on 9 sample ports and (b) (4) the system. Your quality unit failed to evaluate whether this system continues to operate in a validated state following these modifications. Furthermore, you have not conducted a risk assessment to support that your bioburden sampling for (b) (4) (b) (4) post these corrective actions is adequate to verify complete biofilm removal. Per your Associate Director of Facilities, this (b) (4) is used as starting material for the (b) (4) system, cleaning of equipment/utensils, upstream processing, and as starting material for the (b) (4). D. On 03/09/2024, your firm recovered Ralstonia pickettii, a gram-negative biofilm forming organism in your (b) (4) system. You determined there was no impact to your (b) (4) system since the (b) (4) was resampled on 03/11/2024 and had passing results. No additional actions were taken other than trending your (b) (4) testing for (b) (4). You do not have evidence that your sanitization process is eliminating biofilm or biofilm forming organism. Per your Associate Director of Facilities, this (b) (4) is used for downstream processing and equipment cleaning. E. On 12/20/2023, you recovered Burkholderia lata (B. cepacia complex), a gram-negative biofilm forming organism in your (b) (4) system. You determined there was no impact to your (b) (4) system since all other samples collected that day obtained passing results. You trended these samples collected (b) (4) for (b) (4) and trended other similar investigations. However, no additional actions were taken, and you do not have evidence that your sanitization process is eliminating biofilm or biofilm forming organism. Per your Associate Director of Facilities, this (b) (4) is used for downstream processing and equipment cleaning.
- 3
Inadequate testing limits for assemblies
Your procedure for testing (b) (4) after use in your drug substance processing is inadequate in that it does not limit of times it could be tested. Specifically, your written procedure for testing process (b) (4), SOP-01444, Use and (b) (4) Testing of Solution and (b) (4) Assemblies in the Manufacturing and Facilities, Version 22, has a limit of (b) (4) (b) (4) tests before contacting the area manager. Per this procedure, the area manager can approve additional (non-defined) (b) (4) testing. This procedure is inadequate to detect (b) (4) failures.
- 4
Unsuitable microbiological methods
You have not ensured your microbiological methods are suitable for your operations. You have not performed a risk assessment or evaluation to determine if your current bioburden methods of testing for both total aerobic microbial counts (TAMC) and total yeast microbial counts (TYMC) using both (b) (4) and (b) (4) media is suitable for recovering organisms that could potentially pose a risk to patients in light of the spore forming isolates (bacteria and mold) routinely recovered in your facility. Per your Sr. Quality Director, your organization "does not have a tolerance for spore-formers" and further stated "mold is bad." Your current process does not screen for specific organisms. Per your Sr. Scientist of Microbiology, there is no trigger to evaluate the capability of the methods once it's approved for use.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3000718852, newest first.
- Form 483, April 2021Inspection ended Apr 21, 2021 · Posted Aug 26, 2021VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.