Pharmcore Inc. dba Hallandale Pharmacy
2666 Sw 36th St, Fort Lauderdale, Florida, United States
FEI 3014480778
FDA has 3 inspections on file for Pharmcore Inc. dba Hallandale Pharmacy in Fort Lauderdale, Florida (FEI 3014480778), from 2018 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDA published 2 citations from this inspection. They are listed below. Two FOIA requests have asked FDA for this inspection's 483.
The most recent OAI inspection ended on Jul 13, 2018. FDA issued a warning letter on (CDER). 1 import refusal is filed under this FEI, on . No court action is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2018–2025
- 1 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- 1 posted 483 not matched to an inspection
- Requested under FOIA
- 2 requests, latest May 14, 2026
- Warning letters
- · CDER ↗
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Inadequate smoke studies
Smoke studies were inadequately performed under dynamic conditions.
- FDCA 501(a)(2)(A)
Exposed to lower quality air/ISO 5
Materials were exposed to lower than ISO 5 quality air.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Cleaning cross-contamination risk
Cleaning procedures are inadequate to prevent cross contamination. Specifically, Your firm cleans and disinfects the sterile compounding suites for hazardous and non-hazardous drug products [illegible] basis prior to aseptic activities. Your current procedure is to clean the sterile hazardous suite first before cleaning the sterile non-hazardous suite. The order in which you clean is inappropriate because it may potentially cross contaminate and introduce hazardous materials into the non-hazardous suite. Furthermore, your QA Director stated that while the technician will change sterile gloves and sterile booties, he/she does not re-gown in-between.
- Observation 2
No remedial action for positive microbial finds
You did not take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production. Specifically, Your QA Director stated that a thorough '[(b)(4)]' clean is conducted when an objectionable microorganism is found during environmental monitoring of your ISO classified areas. However, your firm failed to thoroughly clean and disinfect the sterile hazardous and sterile nonhazardous rooms containing the ISO5 biosafety cabinet (BSC) and ISO5 laminar airflow hood (LAFH) after actionable microbial contamination was recovered whether or not objectionable microorganisms were found. For example: • Staphylococcus epidermidis was isolated during the active air sampling conducted on March 29, 2021 in the ISO5 BSC during the aseptic production of Gonadorelin HCl 2mg, Lot #97145. • Staphylococcus epidermidis was isolated during the post process surface sampling of Ipamorelin 9mg, Lot #97277 conducted on March 29, 2021 in the ISO5 LAFH. • Micrococcus luteus was isolated during the active air sampling conducted on April 26, 2021 in the ISO5 BSC during the aseptic production of HCG 5000 IU, Lot #100385. • Bacillus megaterium was isolated during the postprocess fingertip sampling of Testosterone Cypionate 200 mg/ml, Lot #98400 conducted in the ISO5 BSC on April 8, 2021.
Show observation 3
- Observation 3
Materials not disinfected before entry
Materials or supplies were not disinfected prior to entering the aseptic processing areas. Specifically, On 9/15/2021, I observed your sterile technician fail to properly disinfect the plastic bag containing the sterile [(b)(4)] and sterile [(b)(4)] used to [(b)(4)] and collect the mixture of Gonadorelin, Lot #117356 prior to placement in the ISO5 Laminar Flow Hood which is located in your firm's ISO7 Mixing/Weighing room for sterile non-hazardous compounded drug products.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Dirty, particle-generating classified areas
The ISO-classified areas have difficult to clean, particle-generating, or visibly dirty equipment or surfaces. Specifically, 1. Visible signs of debris and residue build-up were observed in the following ISO 5 areas located in the Sterile Suite: (b)(4) (b)(4) a. Underneath the "grate" (return air slots) located on the edge of the Class II BSC (ISO 5 Hood), located in the hazardous area; b. Underneath the "grate" (return air slots) located on the edge of the [QJIQ] class II BSC (ISO 5 Hood), located in the non-hazardous area; c. On the back side of the work surface area of the [li)IQ Class II BSC (ISO 5 Hood), in the non-hazardous area. 2. Visible discoloration that appears to be rust was observed in the following classified areas of the Sterile Suite: a. On the front, bottom portion of the [UJICJl class II BSC (ISO 5 Hood) located in the non-hazardous area; b. On the bottom support beam of the stainless-steel prepping table, located in the ISO 7 area approximately . ~ from the Class II BSC (ISO 5 Hood), in the hazardous area; c. Along the outside of the UiJJQl Class II BSC (ISO 5 Hood) located in the non-hazardous area. d. On the underside of the stainless-steel prepping table, located in the ISO 7 area approximately ·p...-,..p..~-1 from the [llCJ] Class II BSC (ISO 5 Hood), in the non-hazardous area; e. On the floor of the ISO 7 area, located in the non-hazardous area of the Sterile Suite. 3. Visible signs of debris and residue build-up were observed in the following ISO 7 areas located in the Sterile Suite: a. On the HEPA filters located on the ceilings in the non-hazardous area (ISO 7); b. On the top of the sliding door that separated the non-hazardous area (ISO 7) from the Anteroom (ISO 7); c. On the top of the sliding door that separated the non-hazardous area (ISO 7) from the hazardous area (ISO 7). 4. Dedicated mop heads used for cleaning of the floors and llDJQ) cleaning of the walls appear to be particle generating/shedding and have visible signs of fraying.
- Observation 2
Inadequate controls for sterile environment
Your firm continued producing sterile drug products within your facility without establishing adequate controls to prevent contamination of the production environment. Specifically, 1. Your firm cut 3 (three) holes in the ISO7 vinyl walls of your Sterile Suite, which is surrounded by non classified areas, potentially compromising the sterility assurance of your Sterile Suite. 2. Your firm's management stated the air pressures, Biological Safety Cabinets (BSC) (ISO 5), lights, and NC are turned off in the Sterile Suite during cleanings and should be manually turned back on after cleaning. On 07/02/2018, we observed the air ure and the BSC Hoods (ISO 5) remained shut off after cleaning was completed for approximately MIDI~ • During this lllDM time period, the vinyl walls of your firm's modular sterile suite enclosure system appeared to become concave. However, the documentation provided by your firm did not demonstrate that the controls in place prevented the influx of contamination from the surrounding non-classified areas into the Sterile Suite production environment during this - time period. Aseptic drug production occurred in the Sterile Suite following this cleaning. According to your firm's distribution log, [llQ] prescriptions for sterile drug products were produced in this Sterile Suite from 02/01/2018 - 07/02/2018, resulting in the shipment of [liJIQ] units of drug product. 3. We observed 3 unsealed holes in the [llQ] Class II BSC (ISO5 Hood), located in the non-hazardous area of the Sterile Suite. 4. We observed 3 large "patched" areas in your sterile suite: a. We observed a patched area, approximately 36.5" width x 44" length, where an t mBIJ was removed, located in the non-hazardous Sterile Suite Area (ISO 7). b. We observed a patched area, approximately 33.5" width x 41" length, where an RPl@1 was removed, located in the non-hazardous Sterile Suite Area (ISO 7). c. We observed a patched area, approximately 32" width x 36" length, where a- as removed, located in the hazardous Sterile Suite Area (ISO 7). 5. We observed what appears to be a cylinder foam tube, located within the ISO 7 non-hazardous Sterile Suite. ~our firm's owner, this cylinder foam tube was placed to fill a gap between the (b)(4) mmum and the vinyl wall in order to help stabilize the air pressure. 6. We observed what appear to be dead insects in your firm's fluorescent light fixture, located in the Non-Sterile Suite (ISO 8), where drug components are mixed prior to undergoing aseptic processing in the Sterile Suite (ISO 7). For example, on 07/02/2018, your firm's owner stated MIC Formula #2, Lot #MICF2C41, was weighed and mixed in the Non-Sterile Suite (ISO 8) prior to entering the Sterile Suite (ISO 5 and ISO 7) areas on 07/03/2018. 7. The (b)(4) is used prior to aseptic processing in your firm's sterile suite. According to the manufacturer's recommendations, the nozzle should be cleaned o~is. However, according to your firm's Quality Assurance Assistant, your firm has not cleaned the ~ in at least over a year. In addition, your firm does not have any written procedures or documented logs related to the cleaning of this equipment.
Show observations 3 to 5
- Observation 3
Deficient environmental monitoring system
The system for monitoring and maintaining environmental conditions in the aseptic processing areas was deficient. Specifically, 1. On 06/11/2018, your firm used an outside contractor to conduct viable air samples. On 06/26/2018, the contractor notified your firm received an out-of-compliance air sample resulting in a non-sporulating colony for fungal growth in your firm's Hazardous Room (ISO 7), located in your Sterile Suite. Your firm continued aseptic operations after receiving this notification for the following lots, including but are not limited to: a. Human Chorionic Gonadotropin Lyophilized 6000IU Vial: Lot Numbers: HCG60128; HCG60129; HCG60130; HCG60131; HCG60132; HCG60133 b. Human Chorionic Gonadotropin Lyophilized 5000IU Vial: Lot Numbers: HCG50333; HCG50334; HCG50335; HCG50336; HCG50337 c. Testosterone Cypionate (Sesame Oil) 5ML Vial Injectable 200MG/ML: Lot Numbers: TCYZS-121; TCY2S-122; TCY2S-123; TCY2S-124; TCY2S-125; TCY2S-126; TCY2S-127 d. Testosterone Cypionate (Grapeseed Oil) 5ML Vial Injectable 200 MG/ML: Lot Numbers: TC20G165; TC20G166; TC20G167; TC20G168; TC20G169; TC20G170; TC20G171; TC20G172; TC20G173 e. Sermorelin Lyophilized 9MG Vial: Lot Number: SER9-78 2. On 07/05/2018, during the in-house sampling for surface and personnel batch environmental monitoring we observed the following: a. The aseptic technician did not roll the contact plate against the workbench surface to ensure full plate contact. b. The aseptic technician lightly touched their fingertips on the plates instead of rolling off fingertips on the media to ensure full plate contact. c. The plates used for sampling were not pre-labeled prior to sampling. After sampling had been conducted, the aseptic technician could not recall the location of where the sampled plates taken. We observed them erase the sample location and re-write on the same plate. Formula #3 30ml Vial Injectable 25mg/50mg/50mg/0.5lmg/0.009ml, lot #MCY0593 was produced on this date.
- Observation 4
Supplies not disinfected before transfer
Equipment, materials, and/or supplies are not disinfected prior to entering the aseptic processing areas. Specifically, 1. Personnel were observed touching equipment or other surfaces located outside of the ISO 5 area with gloved hands and then proceeding with aseptic processing without changing or sanitizing gloves. On 07/03/2018, we observed your pharmacy's aseptic technician gathering drug components and supplies, located outside the ISO 5 area, without changing or sanitizing their gloved hands 11 times during the aseptic drug processing of Methionine, Inositol, and Choline Chloride (MIC Formula #2), Lot #MICF2C41. 2. Equipment, materials, and/or supplies are not disinfected prior to entering the aseptic processing areas. According to your firm's Quality Assurance Assistant, materials are not disinfected during transfer from a dirty area to a cleaner area, which are utilized for sterile drug production. For example, materials transported from a non-classified area to the Anteroom (ISO 7) and from the Anteroom (ISO 7) into the non-hazardous room (ISO 7), are not disinfected.
- Observation 5
ISO-5 areas uncertified dynamically
ISO-5 classified areas were not certified under dynamic conditions. Specifically, 1. Your firm has ly fon11ed smoke studies under dynamic conditions in the ISO 5 areas (biological safety cabinets and B " ll area) located in your Sterile Suite Room since June 2016.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on May 14, 2026. Each one asked for a Form 483.
Inspection ending Jun 13, 2025VAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- May 14, 2026FDA-FOIA-2026-4941Form 483· 1 of 5 sitesWithdrawn
- Aug 25, 2025FDA-FOIA-2025-10152Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3014480778, one row per refused product line.
1 refusal on 2024-04-12 · charged UNAPPROVED on 1 · no FDA sample analysis
FDA firm profile- 2024-04-12
INSULIN I 125 (RADIOACTIVE AGENT)65NCY31
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-4994419-0/11/1
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3014480778 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3014480778. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.