Skip to content

Lupin Limited Form 483, July 2016

FDA issued this Form 483 to Lupin Limited in Vadodara, India (FEI 3005906909) at the end of a drug inspection that ended July 6, 2016. It lists 2 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 29, 2016. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jul 6, 2016
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Nov 29, 2016
146 days after the inspection
Facility
FEI 3005906909
Vadodara, India

The 2 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Unvalidated disinfectant/fumigation procedures

    The firm failed to validate disinfectant and sanitization procedures used in the clean controlled manufacturing areas and did not ensure that product quality is not compromised. For example, A. The firm has fumigated the Plant ®®), the clean controlled Powder Processing Areas, ®® times in 2014, 2015, and 2016 with disinfectant solution according to SOP AMP-044-02, titled "Fumigation in Powder Processing Area", effective date 6/25/2016, after microbiological environmental monitoring alert levels were exceeded. The Powder Processing Areas are used in finished API production, for example for ®® (0) 4) and @® USP. When fumigation is to be done, the solution is aerosolized to cover the entire area of a room. The firm removes equipment and product stored in the room prior to fumigation, but when product in ®® drums cannot be removed from the room, the procedure states the drums "shall be covered properly as to avoid cross contamination." The firm did not do the following prior to implementing the fumigation procedure: • Validate the sanitization to ensure that the method used to cover the product drums prevents contamination of the product from the fumigation agents. • Establish that product quality is not impacted from the fumigation. • Record in the fumigation logs which product in drums were left in the rooms.

  2. 2

    No specific identity testing of vendor material

    The firm failed to perform specific identification tests on the vendor supplied ®® that is used to create an (0) 4) for the bulk packaging of APIs. Specifically, your firm's receipt of the ®® material, used in the ®® of your firm's ©) drug substance packaging was accepted for use with supplier provided COA for the raw material, in lieu of testing of the raw material for conformity with all appropriate written specifications, without performing at least one specific identity test on the raw material and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.