Claris Injectables Limited Form 483, August 2016
FDA issued this Form 483 to Claris Injectables Limited in Ahmedabad, India (FEI 3004610460) at the end of a drug inspection that ended August 26, 2016. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 29, 2016. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Aug 26, 2016
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 29, 2016
- 95 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Laboratory procedures not followed
LABORATORY SYSTEM OBSERVATION 1 Written production and process control procedures are not followed in the execution of production and process control functions. Specifically,-- a) On 8/22/16 an analyst was observed conducting endotoxin testing on Injectable Lot # “and Lot # ©@®. Per the firm’s SOP # ~~ QCD/018, titled, “Bacterial Endotoxin Test”, the endotoxin samples are to be inverted 180 degrees to observe if there is gel formation on the bottom of the test tube. The analyst observed conducting the testing, was tilting the sample test tubes less than 90 degrees when obtaining test results on multiple test samples. The angle the test tubes were observed being tilted to was not sufficient to consistently indicate gel clot formation and show a positive result for the presence of endotoxin. b) Laboratory media used for sterility testing is not labeled following SOP # QCD/014, titled, “Media Preparation” which states under storage of prepared media, that each media tube is to be stored with the media identification name, lot number and date. However, media is not identified using lot #, name, or date made or expiring. Several racks of test tubes containing media for and used in sterility testing were observed sitting in the incubation room with no label affixed or identification marker of any kind showing traceability or identification of the media. Further, sterility samples prepared in the sterile testing area of the microbiology laboratory are loosely affixed with a label that is easily detached and may be removed or lost and may in return compromise the identity and traceability of the sample. c) Media plates generated from Environmental Monitoring/Sampling and personnel testing, that are to be read by the Auto Colony Counter, are wiped free of their identification label showing date, location and employee tested if applicable, prior to being placed in the Auto Colony Counter for reading. The recorded digital photo taken by the Auto Colony Counter, showing results and colonies counted, does not include plate identification in the photo and hence does not ensure traceability of results. Per SOP # QAD/037, titled, “Auto Colony Counter”, plates are to be affixed with the proper label as described in SOP # QAD/037, titled, “Clean Room Monitoring”. The plates observed being read did not have a label, and the discarded plates that had been already read were observed as not having a label.
- 2
Inadequate sampling for BET
OBSERVATION 2 Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet appropriate statistical quality control criteria as a condition for their approval and release. Specifically, samples collected for BET testing, per SOP # W/QAD/032, titled, "Finished Product Sampling", are not collected in sufficient quantity to be representative of the final batch.
- 3
Unqualified apparatus used
OBSERVATION 3 The use of apparatus not meeting established specifications was observed. Specifically, the ™* used during sterility testing has not been qualified for that purpose.
- 4
Clean room contamination controls lacking
PRODUCTION SYSTEM OBSERVATION 4 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, a) SOP PRD/004 Clean Room Entry - Exit Procedure requires use of sterile garments prior to entry into the clean room area. However, you have not validated the number of cleaning and sterilization cycles through which the garments can be processed and are relying on the supplier's recommendation of Dem © cycles. b) SOPs PRD/004 Clean Room Entry - Exit Procedure, which is applicable to the clean room areas of the plant, which includes lines utilized in the manufacture of pharmaceuticals destined for the U.S. market, including: om DEO ©@ requires use of sterile goggles prior to entry into the clean room area. However, you have not validated the number of cleaning and sterilization cycles through which the goggles can be processed and are relying on visual inspection of the goggles by clean room operators. c) Your Disinfectant Validation Reports dated August 2011 and November 2013 identify disinfectant/sporicidal contact times as for and | @ for’ Ee However, no contact time is specified in SOP PRD/006 on Maintenance of Clean Room, which is applicable to the clean room areas of the plant, which includes the bag packing area and pre-sterile area in plant, which includes the lines utilized in the manufacture of pharmaceutical products manufactured for the U.S. market, including: d) The 2016 smoke study performed in the filling area of jbl line utilized in the manufacture of drug products including “ of was inconclusive with regard to laminar air flow or the proper function of the air particle counter. e) Revalidation Protocol /MFIL . 2015 states that media fill studies on line(®) utilized to manufacture EOE © for the U.S. market, are performed EN
- 5
Inadequate employee training
QUALITY SYSTEM OBSERVATION 5 Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions. Specifically, a) SOP PRD/041 Automatic Visual Inspection Procedure, operators performing manual visual examinations of filled drug products are trained to identify defects utilizing test kits. The inspector observed selected examples of filled bags utilized for training operators to detect defects in®® mL and found one bag with a defect marked with an X and another bag with a black dot in the tub categorized as "Good". b) According to SOP CF/CQA/023, newly hired employees with industry experience of Or more are not required to complete on-the-job training nor are they required to perform job specific activities under supervision of a trainer.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3004610460, newest first.
- Form 483, January 2023Inspection ended Jan 27, 2023 · Posted Jan 30, 2024OAI
- Form 483, August 2017Inspection ended Aug 4, 2017 · Posted Oct 19, 2017OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.