FDA has 9 inspections on file for Baxter Pharmaceuticals India Pvt Ltd in Ahmedabad, India (FEI 3004610460), from 2009 to 2023. The latest ended on and was classified OAI, official action indicated. FDA has issued 3 warning letters under this FEI, the latest on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 9 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One FOIA request has asked FDA for this inspection's 483, and one more for the 483 from a later inspection, ending Jun 27, 2025, that FDA's Data Dashboard doesn't list yet.

No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis and sterilization, through Dec 31, 2027. Its registrant, Baxter Healthcare Corporation (D-U-N-S 005083209), has registered 14 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
9, 2009–2023
3 OAI · 6 VAI · 0 NAI
Inspections with 483 observations shown
3 of 9
Form 483s posted by FDA
↗
3 posted
Requested under FOIA
2 requests, latest Oct 2, 2025
Warning letters
· CDER ↗
3 on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. In-Process and Laboratory Control Results

      The batch production and control records are deficient in that they do not include in-process control results.

    2. Written procedures followed

      Procedures for the preparation of master production and control records are not followed.

    3. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

    4. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    5. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    Show 4 more citations
    1. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    2. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

    4. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Environmental monitoring electronic records unsupported

      OBSERVATION 1 Electronic records do not support the authenticity of environmental monitoring: a 09 0© data does not support documentation of environmental monitoring. Specifically, data in the system that registers entry into classified areas by’ access does not support the integrity or accuracy of paper based environmental monitoring reports. For example, per? data the following individuals were absent from rooms where environmental moni- toring purportedly occurred: - (©) 4) Date Operator | Line Affected Batch ©) (6) Sb) © @) li] January 4, 2017 Linew [ii [January 4,2017 Line liii [January 6, 2017 Line N/A January 1, 2017 Line 0 January 9, 2017 Line January 10,2017 Line (vii) Document “Report of Environment Monitoring By Settle Plate for Line” captur- , = ®) ; ©©) ing the environmental monitoring of Line for January 6, 2017 specifies that operator, con- : ered © @) ©) 3 ducted environmental monitoring for; However, the oEYStem fails to support that this operator entered the room during those times. Specifically, the data indicates entered the®® line at™® on January 6, 2017, however, the environmental monitoring documentation reports they were there throughout the 17:00 hour. Similar examples in June 2017 were noted, as evidenced by “Report of Environment Monitoring By Settle Plate” documents dated June 14, 18, 22 and 29. Further, operator®® has no history in the system to support that they ever entered these areas to conduct environmental monitoring. Similarly, operator’ who is documented as conducting environmental monitoring in June 2017 has no history in the®® systent. A written statement was provided that explained “as of today that there are inconsistencies in the recording of 2 controls in the ‘Environmental Monitoring’ area of the Claris Facility to the existing physical log books.” b. Electronic attendance records to support employee entrance to the facilities fail to support envi- ronmental monitoring. Specifically, environmental monitoring records indicate that environmen- tal monitoring was conducted by personnel who were not denoted as present by this attendance system. Examples follow: p ©) [Date | Operator Affected Batch ©) ©) Tm) ©) January 9, 2017 Line January 10, 2017 Line Line 1 January 12, 2017 Line | Line | N/A January 13, 2017 Line || N/A January 15, 2017 Line I Line | N/A The Senior Manager — Quality Assurance and Junior Manager — Microbiologist confirmed the discrepancies between the electronic attendance records versus the environmental monitoring records. Firm management provided a paper based “Attendance Sheet for the month of Jan’2017” to ex- plain the aforementioned inconsistencies between the attendance and environmental monitoring records. The Associate Vice President — Human Resource Management acknowledged that the paper based records exhibits inconsistencies with the electronic system. On July 29, 2017, the “Attendance Sheet for the month of June’2017” was obtained and appears incomplete. Note: 2 data does not support that individuals noted in the table above were on the premise during the purported environmental monitoring. Rather, data supports the at- tendance record that the individuals were not present. c. The Senior Microbiologist is responsible for observation of Environmental Monitoring (EM) plates. On July 31, 2017, Senior Microbiologist was provided with various “Environmental Monitoring By Seitle Plate” forms with multiple variations of signatures documenting the same person. The Senior Microbiologist explained all of these signatures were his, but was unable to sign in a manner consistent with what was captured in all of the documents. The Vice President, Corporate Quality Assurance identified this individual as the person who signs with “three dif- ferent names [signatures]” in environmental monitoring records.

    2. Observation 2

      Controlled documents not appropriately controlled

      OBSERVATION 2 Controlled documents are not appropriately controlled: a. On July 27, 2017, Operator” ® vas observed backdating the Quality Assurance “Visual Inspec- tion Test For®® Line” for®® Injection USP batch®® in the production area of the firm’s facility. For example: a.1 - Section D titled “Manual VIT at the time of Loading” indicates a visual inspection test was completed on July 26, 2017, however, the corresponding data is missing. On July 27, 2017, Op- erator” was observed completing this document. a.2 - Section E titled “Visual Inspection Record For” Machine (Automatic Visual In- spection Machine)” indicates a visual inspection was completed on July 26, 2017 that was signed as “Checked by Packaging”, however, the corresponding data is missing. On July 27, 2017, Op- erator” ®was observed completing this document. When asked about these discrepancies, the Deputy General Manager stated “I don’t know”. SOP CF/CQA/003 titled “Good Documentation Practice” stipulates that “Back date entries are never permitted.” b. On July 28, 2017, official, original documentation were observed in the “scrap” area of the BS building (the area used for the manufacture of US products): b.1 - Regarding a manually torn document with an original signed “Checked By” section, the Vice President, Quality stated that the document appears to be a quality investigation. No addi- tional information regarding the signature or contents of the torn document was provided. b.2 - In addition, there were manually torn pages with unexplained calculations and lot infor- mation. c. On August 2, 2017, the Senior Manager of Quality Assurance provided identical versions of en- dotoxin testing reports for lot and™® (both at time 3:26:03PM) containing unique signatures and writing styles. The dating and timing on both versions is purported to be identical. d. A paper shredder is maintained in the Quality Assurance area of the; building (the area used for the manufacture of US products). The Senior Vice President — Manufacturing & Opera- tions stated this shredder is utilized for “labels” and “printer errors”. However, upon reviewing the paper shreds, we identified writing and stamps on the documents. Documentation supporting the content and reconciliation of destroyed documents was not available. e. There arel” paper shredders located in the following departments / locations i.e., packing department, QA/IPQA department, QA laboratory, in-coming materials warehouse and in the Corporate QA department. The Deputy General Manager Compliance confirmed that the departments do not register and/or maintain a record of all of the documents and paper records that are shredded.

    Show observations 3 to 9
    1. Observation 3

      Complaint follow-up deficient

      OBSERVATION 3 Complaint follow-up is deficient: In 2017, complaints were opened for Injection USP mg/ml for injec- tion site reactions such that the veins became red. For example, these complaints were attributed to “administration procedure” with no requisite for corrective or preventative actions. Complaint Product Number of Affected Patients CI1/PCR/2017/013 | Injection | 6 (2 with batch®® ] C1/PCR/2017/028 Injection | 1 batch) C1/PCR/2017/029 Injection | 1 (batch The General Manager of Corporate Quality Assurance explained that these site reactions may be at- tributed to drug product not being pyrogen free (presence of bacterial endotoxin). The complaint inves- tigation relied on additional product testing without further follow-up. The Senior Manager of Quality Assurance elaborated that endotoxin levels are homogenous (“throughout”) a batch and it would be ex- pected for an endotoxin contamination to be ubiquitous throughout the batch. Incidents related to injection site reactions for have been increasing as summarized below: Reaction Site Complaints - © | 2014 2015 2016 m7 | Year |

    2. Observation 4

      OOS results invalidated without justification

      OBSERVATION 4 Out-of-Specification (OOS) results are invalidated without an adequate justification: OOS results pertaining to the US market are frequently invalidated and described below: a. The following OOS results for stability samples were invalidated due to “column efficiency”. No chromatographic errors were discerned, including retention times, theoretical plates and tail- ing factor. Nevertheless, the OOS results were invalidated and passing retest results were report- ed. When asked if these results would have been invalidated should they have yielded passing result, the Deputy Manager of Stability Studies stated “never”. [00S |] Product Batch Analysis | 008/2017/CF/004 [4 Injection | e Assay Injection [®® &P Assay b. 9 of 16 invalid OOSs pertaining to stability samples were invalidated due to dilution/ pipetting errors. Despite 56% of OOS results invalidated due to dilution/ pipetting errors, no comprehen- sive CAPA has been opened [+ trainings regarding sample preparation are reported in the past two years). The following include examples of invalidated OOSs without adequate justification: b.1 - The following OOSs for content of Injection were invalidated due to an assignable cause of standard solution contaminating the sample solution in the pipette. The OOS results were above specification. However, the standard solution yielded a lower peak area than the sample. It is unclear how a solution of lower”? content contaminating the sample would yield an OOS above the specification. The QOS results were invalidated and passing retest results were reported. b.2 - 00S report 00S/2017/CF/035 for injection (batch ®@®! was inval- idated due to identification (via interview) of a dilution/ pipetting error. The analyst that ran the chromatographic sequence was interviewed; the interview did not include the analyst who per- formed the pipetting and dilution for generating the sample. The OOS results were invalidated on the interview of the analyst that performed the chromatography. c. 00S report 00S/2017/CF/018 pertaining to stability samples for > oermeability of [ Injection (batches™ and®?®@ were invalidated with “assignable root cause could not be identified”. The failing results for batches™® and of 29, and ®®%, respectively, were invalidated and passing retest results were reported.

    3. Observation 5

      Water intrusion and ceiling damage in corridor

      OBSERVATION 5 During a walkthrough of the facility we observed within the personnel corridor (Note: corridor leads in- to the personnel entryways that lead into the controlled classified manufacturing areas) approximately 27-28 separate areas in the ceiling where water was either dripping, seeped and/or soaked through the building structural material. This is evident, for example, by water dripping from the ceiling, a small accumulation of water on the personnel corridor floor and varied water stains on the walls of the person- nel corridor. In addition; a. In the personnel corridor there is an approximate 15.24cm (h) x 12.7cm (w) breakage of the building wall structure material; b. There is a ceiling panel over the personnel corridor lighting fixture that is open (not sealed) such that it allows the ingress of air from the building’s plenum and location of the air handling units (Note: by touch the ceiling material appeared to be a bit damp); c. There is a ceiling panel and opening (approximate 45 72cm x 5.05cm) over the sterilizer that allows the ingress of air from the building’s plenum into the post sterilization area.

    4. Observation 6

      Media fill records falsified/exceed reconciliation

      OBSERVATION 6 Media fill records are false: a. The most recent media fill for Line @ (batch completed in December 2016) is false. Senior Executive - Microbiologist acknowledged that microbiology completed the media fill batch record. The batch record was signed by Senior Executive Microbiologist on December 4, 2016. Howev- er, the Senior Executive Microbiologist was off on this date. The reconciliation for media fill vials for batch exceeds 100%. Specifically, the docu- ment entitled “Summary of Process Simulation Study” (document C1/MFIL/TERMINAL) indi- cates that, containers had been filled with®® “ontainers incubated However, the batch record documents 7 vials had been rejected. Furthermore, the number of rejects between the “Summary of Process Simulation Study” and the “Batch Manufacturing Record” for batch [+ is irreconcilable. b. The most recent media fill for Line {g) (batch completed in December 2016) is false. The Senior Microbiologist confirmed that microbiology department completed the media fill batch record. The Senior Executive Microbiologist completed the batch record on December 30, 2016 after 08:54. However, the attendance records document that they completed the®® at 08:54 on this day. For example, the Batch Manufacturing Record for batch documents that the rec- ord was completed in the afternoon of December 30, 2016. The Senior Executive Microbiologist acknowledged writing this page despite not being present on the premise during these times. The reconciliation for media fill vials for batch? exceeds 100%. The “Record of Obser- vation for Incubated Containers” (form SF/C1/MFIL/SVP/013) indicates that>® containers had been observed after incubation). However, per the Batch Manufacturing Record and “Sum- mary of process simulation Testing (Media fills trial)” (document (C1/MFIL/SVP) indicates that only containers had been subject to incubation. c. Regarding personnel movement in fill line 1 | the layout of the fill equipment, design of the ISO-5 area within the ISO-7 room requires gowned personnel to 20 he fill line conveyor belt; a similar concern and personnel movement occurs in the vial capping line.

    5. Observation 7

      Deficient aseptic technique during interventions

      OBSERVATION 7 Aseptic technique is deficient: During the manual intervention the fill room operator was observed manually placed the lid of the EM settle plate covering the” petri dish, which precludes from obtaining a representative FM sample during the manual intervention. a. The EM personnel was observed placing their gloved hand under the RABs barrier and into the ISO-5 fill zone while positioning the NVP probe in order to conduct the NVP measurements. b. During NVP measurements a leak from a filling™® “was observed on the fill line with an ac- cumulation of liquid in the ISO-5 fill zone. c. After the NVP measurements were taken the fill room operator conducted a manual intervention to replace the fill the RABs access ®® was opened throughout a period of] During this time, the operator's” was observed within the ISO-5 fill zone, which in- cluded frequently contacting the KAB's] © * d. Subsequent the aforementioned activities noted above the{”® “and the area surrounding the fill [+ were not subject to cleaning/ sanitization.

    6. Observation 8

      Airflow/smoke study deficiencies and gaps

      OBSERVATION 8 The air flow pattern evaluations (aka smoke studies) are performed to “demonstrate and assure that the LAFs” in the| ine and line “are capable enough to provide Unidirectional Air flow to the work station and there are not turbulence observed and/or any non-unidirectional movement of the air observed so as to maintain the laminarity of the air flow with the LAF work station.” Similar air flow pattern considerations and evaluation principles have been performed in support of the area qualification for the™® Line. A review of the air flow pattern videos document the following concerns e.g; a. There are a number of instances documented in the videos where there is no smoke placed over the personnel manual interventions in order to visualize the impact upon the unidirectional flow of air within the ISO-5 area; b. There is no simulation regarding opening and closing of RABs access or of the barrier®® to demonstrate that the unidirectional flow of air is not compromised during rou- tine operations; c. There are a number of instances when personnel perform some form of manual interventions within the ISO-5 area. However, due to the position of the fill room personnel, their position blocks the video camera and prevented the ability to observed the manual intervention and the impact upon the unidirectional air flow; d. Fill room personnel perform a manual intervention“ the conveyor that transfers the glass vi- als from the fill equipment to the vial capping station. The manual intervention requires opening the “bf the conveyor enclosure, at which time the conveyor’s ISO-5 interior is exposed to the ISO-7 environment; e. During the above manual intervention noted above, personnel are performing the task within an 1SO-7 environment. There is no physical partition to separates and control the ISO-5 from the ISO-7 environment.

    7. Observation 9

      EM microbial limits not data-based

      OBSERVATION 9 The “Clean Room Monitoring” document #C1/QAD/004 establishes “two methods of environmental monitoring” i.e., physical and microbial monitoring. “Microbial monitoring aims at obtaining repre- sentative estimation of bio-burden of the environment and detecting an adverse drift in trend of microbi- ological conditions, in a timely manner, which would allow for meaningful and effective actions.” Re- garding the microbial alert and actions limits, the environmental monitoring (EM) program establishes, for example fo) Btu (alert/action) for the ISO-7 andy) fu (alert/action) for the ISO-8 manufactur- ing controlled areas. The EM data for the last three years document microbiological counts, dependent of the ISO classification of the manufacturing area (within a range from Be cfu), are well below the cur- rent microbial limits. The EM microbial alert and action limits are not established or based on the histor- ical performance that is documented in the EM data. In addition, a. The microbial alert and action limits for the Line was initially established from Sept. 18, 2011 to Feb. 01, 2012, for the™ Line on Jan, 01, 2008 and for the "Line on Feb. 04, 2008. The EM data obtained and established from the aforementioned previous years continues as the microbiological foundation in support of the current EM program microbial limits. There are a number of discrepancies with respect to the current EM sampling and data that have a di- rect impact upon the microbial alert and action limits. For example, there are current EM sampling locations that do not correspond to the initial EM sampling locations, there are current

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Laboratory procedures not followed

      LABORATORY SYSTEM OBSERVATION 1 Written production and process control procedures are not followed in the execution of production and process control functions. Specifically,-- a) On 8/22/16 an analyst was observed conducting endotoxin testing on Injectable Lot # “and Lot # ©@®. Per the firm’s SOP # ~~ QCD/018, titled, “Bacterial Endotoxin Test”, the endotoxin samples are to be inverted 180 degrees to observe if there is gel formation on the bottom of the test tube. The analyst observed conducting the testing, was tilting the sample test tubes less than 90 degrees when obtaining test results on multiple test samples. The angle the test tubes were observed being tilted to was not sufficient to consistently indicate gel clot formation and show a positive result for the presence of endotoxin. b) Laboratory media used for sterility testing is not labeled following SOP # QCD/014, titled, “Media Preparation” which states under storage of prepared media, that each media tube is to be stored with the media identification name, lot number and date. However, media is not identified using lot #, name, or date made or expiring. Several racks of test tubes containing media for and used in sterility testing were observed sitting in the incubation room with no label affixed or identification marker of any kind showing traceability or identification of the media. Further, sterility samples prepared in the sterile testing area of the microbiology laboratory are loosely affixed with a label that is easily detached and may be removed or lost and may in return compromise the identity and traceability of the sample. c) Media plates generated from Environmental Monitoring/Sampling and personnel testing, that are to be read by the Auto Colony Counter, are wiped free of their identification label showing date, location and employee tested if applicable, prior to being placed in the Auto Colony Counter for reading. The recorded digital photo taken by the Auto Colony Counter, showing results and colonies counted, does not include plate identification in the photo and hence does not ensure traceability of results. Per SOP # QAD/037, titled, “Auto Colony Counter”, plates are to be affixed with the proper label as described in SOP # QAD/037, titled, “Clean Room Monitoring”. The plates observed being read did not have a label, and the discarded plates that had been already read were observed as not having a label.

    2. Observation 2

      Inadequate sampling for BET

      OBSERVATION 2 Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet appropriate statistical quality control criteria as a condition for their approval and release. Specifically, samples collected for BET testing, per SOP # W/QAD/032, titled, "Finished Product Sampling", are not collected in sufficient quantity to be representative of the final batch.

    Show observations 3 to 5
    1. Observation 3

      Unqualified apparatus used

      OBSERVATION 3 The use of apparatus not meeting established specifications was observed. Specifically, the ™* used during sterility testing has not been qualified for that purpose.

    2. Observation 4

      Clean room contamination controls lacking

      PRODUCTION SYSTEM OBSERVATION 4 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, a) SOP PRD/004 Clean Room Entry - Exit Procedure requires use of sterile garments prior to entry into the clean room area. However, you have not validated the number of cleaning and sterilization cycles through which the garments can be processed and are relying on the supplier's recommendation of Dem © cycles. b) SOPs PRD/004 Clean Room Entry - Exit Procedure, which is applicable to the clean room areas of the plant, which includes lines utilized in the manufacture of pharmaceuticals destined for the U.S. market, including: om DEO ©@ requires use of sterile goggles prior to entry into the clean room area. However, you have not validated the number of cleaning and sterilization cycles through which the goggles can be processed and are relying on visual inspection of the goggles by clean room operators. c) Your Disinfectant Validation Reports dated August 2011 and November 2013 identify disinfectant/sporicidal contact times as for and | @ for’ Ee However, no contact time is specified in SOP PRD/006 on Maintenance of Clean Room, which is applicable to the clean room areas of the plant, which includes the bag packing area and pre-sterile area in plant, which includes the lines utilized in the manufacture of pharmaceutical products manufactured for the U.S. market, including: d) The 2016 smoke study performed in the filling area of jbl line utilized in the manufacture of drug products including “ of was inconclusive with regard to laminar air flow or the proper function of the air particle counter. e) Revalidation Protocol /MFIL . 2015 states that media fill studies on line(®) utilized to manufacture EOE © for the U.S. market, are performed EN

    3. Observation 5

      Inadequate employee training

      QUALITY SYSTEM OBSERVATION 5 Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions. Specifically, a) SOP PRD/041 Automatic Visual Inspection Procedure, operators performing manual visual examinations of filled drug products are trained to identify defects utilizing test kits. The inspector observed selected examples of filled bags utilized for training operators to detect defects in®® mL and found one bag with a defect marked with an X and another bag with a black dot in the tub categorized as "Good". b) According to SOP CF/CQA/023, newly hired employees with industry experience of Or more are not required to complete on-the-job training nor are they required to perform job specific activities under supervision of a trainer.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  8. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Oct 2, 2025. Each one asked for a Form 483.

  • Inspection ending Jun 27, 2025

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Feb 11, 2026. FDAgent holds no copy that FDA posted.

    1. Oct 2, 2025FDA-FOIA-2025-11561Form 483· 1 of 2 sitesRecords released
  • Inspection ending Jan 27, 2023OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jan 25, 2024FDA-FOIA-2024-833Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 9 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis, sterilization
Registration runs through
Dec 31, 2027
Registrant
Baxter Healthcare CorporationD-U-N-S 005083209

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Baxter Healthcare Corporation (D-U-N-S 005083209) as the registrant for this site and 14 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3004610460 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3004610460. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.