Baxter Healthcare Corporation
250 Road #144, Jayuya, Puerto Rico, United States
FEI 2618677DUNS 189326168
Company: Baxter Healthcare Corporation · Linked by exact D-U-N-S match (005083209) in FDA registration data
FDA has 13 inspections on file for Baxter Healthcare Corporation in Jayuya, Puerto Rico (FEI 2618677), from 2009 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. Two FOIA requests have asked FDA for this inspection's 483.
The most recent OAI inspection ended on Oct 3, 2016. FDA has issued 2 warning letters under this FEI, the latest on (CDER). No court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis and sterilization, through Dec 31, 2027. Its registrant, Baxter Healthcare Corporation (D-U-N-S 005083209), has registered 14 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 13, 2009–2024
- 5 OAI · 4 VAI · 4 NAI
- Inspections with 483 observations shown
- 6 of 13
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 2 requests, latest Aug 21, 2024
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
13 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Laboratory equipment calibration records
Laboratory records do not include complete records of the periodic calibration of laboratory instruments.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Sample size - test intervals
The written stability program for drug products does not include test intervals based on statistical criteria for each attribute examined to assure valid estimates of stability.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Show 7 more citations
Buildings not maintained in good state of repair
Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair.
Cleaning/maintenance records not kept
Records are not kept for the cleaning of equipment.
Written program not followed
The written stability testing program is not followed.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the sampling and testing of components.
Reserve samples identified, representative, stored
Reserve drug product samples are not representative of each lot or batch of drug product.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Test methods
The accuracy, sensitivity and reproducibility of test methods have not been established.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Components withheld from use pending release
Each lot of components and closures is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Contamination, chemical or physical change, deterioration
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.
Show 1 more citation
Protection from external factors
Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Contamination, chemical or physical change, deterioration
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.
Components withheld from use pending release
Each lot of drug product containers and closures is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Contamination, chemical or physical change, deterioration
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Acceptance criteria for sampling & testing
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification as a condition for their approval and release.
Contamination, chemical or physical change, deterioration
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.
Written calibration procedures
Written calibration procedures for instruments, apparatus, gauges, and recording devices are deficient in that they do not include specific limits for accuracy and precision.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Aug 21, 2024. Each one asked for a Form 483.
Inspection ending Jul 19, 2024VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Aug 21, 2024FDA-FOIA-2024-7433Form 483· 1 of 3 sitesClosed
- Aug 20, 2024FDA-FOIA-2024-7406Form 483· 1 of 3 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 16 sections of 21 CFR in FDA’s published citations for 6 of this facility’s 13 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit4 of 6
- 21 CFR 314.81Other postmarketing reports4 of 6
- 21 CFR 211.110Sampling and testing of in-process materials and drug products3 of 6
- 21 CFR 211.192Production record review3 of 6
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 6
- 21 CFR 211.160General requirements2 of 6
- 21 CFR 211.165Testing and release for distribution2 of 6
- 21 CFR 211.58Maintenance1 of 6
Show all 16
- 21 CFR 211.67Equipment cleaning and maintenance1 of 6
- 21 CFR 211.80General requirements1 of 6
- 21 CFR 211.94Drug product containers and closures1 of 6
- 21 CFR 211.100Written procedures; deviations1 of 6
- 21 CFR 211.166Stability testing1 of 6
- 21 CFR 211.170Reserve samples1 of 6
- 21 CFR 211.194Laboratory records1 of 6
- 21 CFR 211.198Complaint files1 of 6
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis, sterilization
- Registration runs through
- Dec 31, 2027
- Registrant
- Baxter Healthcare CorporationD-U-N-S 005083209
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Baxter Healthcare Corporation (D-U-N-S 005083209) as the registrant for this site and 14 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- BAXTER PHARMACEUTICALS INDIA PRIVATE LIMITEDAhmedabad, India · FEI 30046104609 inspections9latestJan 27, 2023OAI3 warning letters, latest Jul 25, 2023
- Baxter Healthcare CorporationRound Lake, Illinois · FEI 141698019 inspections19latestApr 2, 2026OAI2 warning letters, latest Sep 29, 2026
- Baxter Healthcare CorporationAibonito, Puerto Rico · FEI 26496148 inspections8latestSep 23, 2026VAI1 warning letter, Jul 17, 2014
- Baxter Healthcare CorporationGuayama, Puerto Rico · FEI 26500909 inspections9latestMar 26, 2025VAI1 warning letter, Jan 20, 2011
- Baxter Healthcare CorporationMarion, North Carolina · FEI 102511411 inspections11latestFeb 9, 2024OAI1 warning letter, May 31, 2013
- Baxter Healthcare CorporationCleveland, Mississippi · FEI 101900313 inspections13latestSep 29, 2025OAINone on file
- Baxter Deutschland GmbHBielefeld, Germany · FEI 30028064145 inspections5latestMay 28, 2025VAINone on file
- Bieffe Medital SASabinanigo, Spain · FEI 30051643654 inspections4latestApr 11, 2025VAINone on file
- Baxter CorporationAlliston, Canada · FEI 30028912604 inspections4latestJan 31, 2025VAINone on file
- Baxter Healthcare (Shanghai) Co. Ltd.Shanghai, China · FEI 30137611461 inspection1latestDec 3, 2024VAINone on file
- Baxter SALessines, Belgium · FEI 30054682652 inspections2latestNov 17, 2023VAINone on file
- Baxter R and D EuropeBraine-L'Alleud, Belgium · FEI 10003590472 inspections2latestFeb 2, 2023VAINone on file
Other FEIs recorded as Baxter Healthcare Corporation
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Baxter Healthcare CorporationFEI 1314492Medina, New York, United States
Last inspected 2025-04-04VAI
Baxter Healthcare CorporationFEI 1417572Deerfield, Illinois, United States
Last inspected 2024-02-06NAI
Baxter Healthcare CorporationFEI 1316463Skaneateles Falls, New York, United States
Last inspected 2023-08-17VAI
Baxter Healthcare CorporationFEI 1036337Largo, Florida, United States
Last inspected 2017-08-23NAI
Baxter Healthcare CorporationFEI 2025695Irvine, California, United States
Last inspected 2017-03-03NAI
Baxter Healthcare CorporationFEI 3006472186Mountain View, California, United States
Last inspected 2016-11-29VAI
Baxter Healthcare CorporationFEI 3007319130Vancouver, Washington, United States
Last inspected 2016-01-07NAI
Not every site is listed: these are the most recently inspected sites found under this name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 2618677 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 2618677. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.