Equipment cleaning and cleaning validation in FDA Form 483 observations
Cleaning procedures for manufacturing equipment, the studies that show they work, and the residues, swabs and logs that prove each cleaning. FDAgent finds 197 such observations in 144 Form 483s issued to 138 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 197
- Each quoted below
- Form 483s
- 144
- Posted by FDA
- Facilities
- 138
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 63 in 2026
| Year | Observations |
|---|---|
| 2008 | 1 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 0 |
| 2013 | 0 |
| 2014 | 1 |
| 2015 | 1 |
| 2016 | 10 |
| 2017 | 15 |
| 2018 | 20 |
| 2019 | 5 |
| 2020 | 5 |
| 2021 | 10 |
| 2022 | 7 |
| 2023 | 22 |
| 2024 | 13 |
| 2025 | 24 |
| 2026 | 63 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
The same entries the equipment cleaning topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“cleaning validat*” · “validat* … cleaning” · “cleaning procedure*” · “cleaning process*” · “cleaning record*” · “cleaning log*” · “cleaning agent*” · “cleaning verification” · “cleaning stud*” · “cleaning method*” · “cleaning effectiveness” · “not cleaned” · “not adequately cleaned” · “not properly cleaned” · “residue*” · “swab*” · “carry over” · “carryover”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 197 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Laurus Synthesis Private LimitedInspection ended Dec 12, 2023 · FEI 3011524794 · Observation 3
… Furthermore, (b) (4) (b) (4) 116, which is also used in the manufacturing of (b) (4) had apparent product residue remaining in the (b) (4) even though the (b) (4) was identified as cleaned. B. (b) (4) 201 used in the (b) (4) had apparent white residue contained on and around the (b) (4). In addition, outside light was observed from the inside of the (b) (4) (b) (4) room where product is final packaged through gaps surrounding the (b) (4). …
Contains “residue*”Read the Form 483 →
Titan Kogyo, LtdInspection ended Dec 8, 2023 · FEI 3009155994 · Observation 3
… COA only included the following: specific gravity, (b) (4) The (b) (4) lot# (b) (4) COA from (b) (4) lists the following analyses: purity, ignition on residue, moisture, (b) (4) foreign matter. The firm's verification testing of the aforementioned supplier COA only included the following: purity and ignition on residue. The (b) (4) lot (b) (4) COA from (b) (4) lists the following analyses: (b) (4) concentration, (b) (4) specific gravity, (b) (4) …
Contains “residue*”Read the Form 483 →
Titan Kogyo, LtdInspection ended Dec 8, 2023 · FEI 3009155994 · Observation 4
Equipment and utensils utilized in the production of API for the US Market are not cleaned or maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, purity and quality of the drug substance. For example: Reddish-brown discoloration was observed on the interior of the water hose to holding vessel (RT-8). The aforementioned hose is utilized in the pumping of water into the ceiling of the vessel …
Contains “not cleaned”Read the Form 483 →
Catalent Indiana, LLCInspection ended Nov 15, 2023 · FEI 3005949964 · Observation 3
… Additionally, 6 on Flexi and (o)(4) on Syringe Line were observed to have an apparent brown residue. 3. On 31 OCT 2023, we (Investigators Tan and Kuo) observed operators performing aseptic connection of the product storage bag to the filling line. We observed that after connection of the connectors to the fill line outside the (6) (4) the unused backup connector outlets were hanging down towards the floor and contacting a (15) (4) Barrier that …
Contains “residue*”Read the Form 483 →
Catalent Indiana, LLCInspection ended Nov 15, 2023 · FEI 3005949964 · Observation 6
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, Work Orders (WOs) 1004043 and 1004053 were opened on 26 OCT 2023 and 27 OCT 2023, respectively, pertaining to incidences of the [(t> -(4) ] malfunctioning on System [(o)e(4 (Syringe) (4) Visual Inspection) in Building D, Room 141, used for visual inspection …
Opens with FDA's citation wording for 21 CFR 211.67(b)Read the Form 483 →
Sumitomo Osaka Cement Co., LtdInspection ended Oct 27, 2023 · FEI 3003943727 · Observation 1
Cleaning Validation Program is deficient, Specifically (b)(4) The firm manufactured and shipped API products for the US market in the past three years each with a different particle size as listed below: Product Name Product Type NDC (b)(4) [illegible] The firm performed three cleaning validations to establish successful product change over cleaning as detailed below for [illegible] Date of completion Result Content Reference A washing amount of …
Contains “cleaning validat*”Read the Form 483 →
Sumitomo Osaka Cement Co., LtdInspection ended Oct 27, 2023 · FEI 3003943727 · Observation 4
… The firm does not monitor appearance and assay of (b)(4) (critical quality attributes) on stability samples of all (b)(4) API for US instead monitors residue on ignition, conductivity and specific surface area. The firm has shipped approximately (b)(4) API batches to US since 2019. 8. Your Training Procedure GMP-SOP-S-005 states to include CGMP training in the (b)(4) training plan. However, no documentation was available for any employee of the …
Contains “residue*”Read the Form 483 →
Linhai Tianyu Pharmaceutical Co., Ltd.Inspection ended Sep 15, 2023 · FEI 3013345425 · Observation 2
… 2) a ~2 feet by 1 foot reddish/brown area of peeling floor under utility pipes that connect to the (b) (4) station 3) a drooping clear coil with reddish/brown residue that connects to utility pipes that connect to the (b) (4) station (b) (4) 217 with a drooping clear coil with reddish/brown residue that carries (b) (4) to utility pipes that connect to the (b) (4) station and (b) (4) tank (b) (4) with a detached floor area of ~1 foot by 1 foot …
Contains “residue*”Read the Form 483 →
Central Glass Co., Ltd.Inspection ended Sep 15, 2023 · FEI 3002806649 · Observation 3
Your cleaning procedures are not validated. Specifically, a) Your firm has not performed validation of the cleaning procedures used to clean equipment that is used for (b) (4) filling API into containers. (b) (4) varies. For example the (b) (4) however the number of consecutive batches manufactured on the equipment in (b) (4) [illegible] b) (b) (4) batches, however the (b) (4) campaign executed to asses the cleaning re-validation study of …
Contains “cleaning procedure*”Read the Form 483 →
Central Glass Co., Ltd.Inspection ended Sep 15, 2023 · FEI 3002806649 · Observation 4
… On 8/6/23 UQSE20-19 test method used to evaluate rinse samples from cleaning validation was changed to obtain a lower LOD and LOQ the residue limit on equipment was also changed from (b) (4) ppm to (b) (4) ppm. The reason for not performing this change using the change control program was not documented. b) Change control CCQ22-17 enacted to address change in storage of (b) (4) medium used by QC from refrigeration to room temperature states that …
Contains “cleaning validat*”Read the Form 483 →
Wickliffe LLCInspection ended Sep 15, 2023 · FEI 3002992930 · Observation 3
Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, On 9/7/2023, during aseptic filling of Reserpine 2.5mg/mL, brown residue was wiped off the bottom of vials that were introduced to the sterile hood for filling. Reserpine is a clear/yellow liquid. More than 9 vials were discarded …
Opens with FDA's citation wording for 21 CFR 211.67(a)Read the Form 483 →
Samsung Biologics Co. Ltd.Inspection ended Sep 1, 2023 · FEI 3010479596 · Observation 2
… inspect materials, probes, parts, and assemblies before use or installation and verify that it is integral and free of debris, surface anomalies, foreign residue, or defects. Observed was no visual inspection of the drug substance container closure systems for absence of defect or debris within each bottle that could have an impact on product quality, with the standard operating procedure not followed. There is no documentation requirement for …
Contains “residue*”Read the Form 483 →
Nortec Quimica S.A.Inspection ended Aug 4, 2023 · FEI 3007616930 · Observation 1
Your firm's cleaning validation is not representative of current equipment usage. Specifically, cleaning validation report NQPV432, approved 08/09/2019, updated cleaning (b) (4) dated 06/03/2022, for the group of equipment covered under (b) (4) which includes: (b) (4) (b) (4) and (b) (4) was validated using (b) (4) as the worst case scenario active pharmaceutical ingredient (API). However, your firm failed to conduct another cleaning validation …
Contains “cleaning validat*”Read the Form 483 →
Ipca Laboratories LimitedInspection ended Jun 23, 2023 · FEI 3007574780 · Observation 4
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, major non-dedicated production equipment such as (b) (4) ID: MFG-159) and two (b) (4) (equipment ID: MFG-162 and MFG-163) used in (b) (4) Area are not cleaned, and maintained at appropriate intervals to prevent contamination that would alter …
Opens with FDA's citation wording for 21 CFR 211.67(a)Read the Form 483 →
Qilu Antibiotics Pharmaceutical Co., LTD.Inspection ended May 30, 2023 · FEI 3009831352 · Observation 1
… After (b) (4) an additional (b) (4) was added to equipment and this volume was used to calculate the level of residue and the quantity of (b) (4) b. For Media fill #(b) (4) (b) (4) were reportedly placed in the drains to capture (b) (4) for the above listed equipment and subsequently emersed into (b) (4) nedia for media simulation incubation. There were no instructions and no documentation in the batch records for the ad c. For Media fill #(b) …
Contains “residue*”Read the Form 483 →
Zen Chemicals Pvt. LtdInspection ended Mar 28, 2023 · FEI 3015345351 · Observation 1
Equipment are not cleaned and sanitized to prevent contamination of the critical API intermediate product. Specifically, your firm failed to complete a clean and dirty hold time study and to establish clean and dirty hold times for (b) (4). Additionally, you failed to ensure that you are able to clean and remove the previous manufactured critical API intermediate with no carryover during changeover cleaning using non-dedicated equipment. On March …
Contains “not cleaned”Read the Form 483 →
Zen Chemicals Pvt. LtdInspection ended Mar 28, 2023 · FEI 3015345351 · Observation 5
Employees are not trained in cleaning procedures. Specifically, Your firm failed to train your employees who perform cleaning, verify that cleaning is adequate and recheck and approve cleaning equipment and sign final cleaning batch to batch or product to product documentation. In reviewing employee's training records, approximately six (6) employees were deficient in training on cleaning SOP, TR/15/05/013. During the inspection, six (6) …
Contains “cleaning procedure*”Read the Form 483 →
SciVac LTDInspection ended Mar 27, 2023 · FEI 3012695367 · Observation 1
… Areas and surfaces of your Grade [illegible] are not cleaned adequately. I observed aseptic open operators cleaning your open (b)(4) during filling operations and after batch (b)(4) was completed. The aseptic operator failed to completely clean the opened (b)(4) door(s) upon completion of an open door (b)(4) intervention. Operator(s) were also observed failing to clean the partition separating the (b)(4) area from the filling area inside your …
Contains “not cleaned”Read the Form 483 →
FRUEH VERPACKUNGSTECHNIK AGInspection ended Mar 24, 2023 · FEI 3010363503 · Observation 1
Procedures for the cleaning and maintenance of equipment are deficient regarding the protection of clean equipment from contamination prior to use. Specifically, your firm has not performed any cleaning validation studies to assess the effectiveness of your cleaning procedures for equipment and rooms used in the packaging operations for (b)(4) drug products. Additionally, no disinfectant efficacy studies have been conducted to ensure the …
Opens with FDA's citation wording for 21 CFR 211.67(b)(5)Read the Form 483 →
Genlbet Biopbarmaceuticals SAInspection ended Jan 31, 2023 · FEI 3011160795 · Observation 2
Equipment cleaning processes are inadequate. Specifically: a. The cleaning validation study (Cleaning Validation Summary Report) performed on (b)(4) contact equipment does not ensure removal of the [illegible]. Specifically: i. (b)(4) was not performed to ensure that the product is removed from the difficult to clean areas. (b)(4) was not assessed. ii. (b)(4) iii. The cleaning validation did not include the maximum lot size of (b)(4). b. …
Contains “cleaning process*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.67Equipment cleaning and maintenanceIn this theme's rule31
- 21 CFR 211.113Control of microbiological contamination10
- 21 CFR 211.42Design and construction features6
- 21 CFR 211.22Responsibilities of quality control unit3
- 21 CFR 211.100Written procedures; deviations2
- 21 CFR 211.192Production record review2
- 21 CFR 211.28Personnel responsibilities1
- 21 CFR 211.56Sanitation1
- 21 CFR 211.58Maintenance1
- 21 CFR 211.94Drug product containers and closures1
Ask FDAgent about equipment cleaning in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.