Zen Chemicals Private Limited
D-5, Midc, Phase-2, Manpada Road, Dombivli, Jalna, India
FEI 3015345351DUNS 871623684
FDA has one inspection on file for Zen Chemicals Private Limited in Jalna, India (FEI 3015345351). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. Two of the three FOIA requests for this site have asked FDA for this inspection's records.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2026. Its registrant is Zen Chemicals Private Limited (D-U-N-S 871623684).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2023
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 3 requests, latest May 28, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Dirty non-dedicated equipment, no cleaning validation
Equipment are not cleaned and sanitized to prevent contamination of the critical API intermediate product. Specifically, your firm failed to complete a clean and dirty hold time study and to establish clean and dirty hold times for (b) (4). Additionally, you failed to ensure that you are able to clean and remove the previous manufactured critical API intermediate with no carryover during changeover cleaning using non-dedicated equipment. On March 13 and 14, 2023, I observed, during the facility walkthrough, the following equipment used to manufacture U.S. marketed critical API intermediate were observed visibly dirty. This includes multiple critical API intermediate contact surfaces. All equipment noted below were in a cleaned state during my visual observation and are non-dedicated. In addition, you do not perform a cleaning verification (e.g. swabbing) of the equipment after material changeover cleaning. A. (b) (4) residue on the inside of the (b) (4) and (b) (4) as well as (b) (4) and (b) (4) residues on the corner of the (b) (4) were observed on product contact surface, the inside side of the equipment # ZEN/MC/P-56 located in the (b) (4) area. Batch to Batch cleaning was conducted on March 14, 2023. B. (b) (4) residue in the (b) (4) and (b) (4) below the bowl of the (b) (4) residue in (b) (4) and (b) (4) and (b) (4) were observed on the (b) (4) of the equipment # ZEN/MC/P-31 located in the (b) (4) area. Batch to Batch cleaning was conducted on March 13, 2023. C. (b) (4) residue around the circumference of the bowl of the (b) (4) were observed on the (b) (4) equipment # ZEN/MC/P-62 located in the (b) (4) area. Batch to Batch cleaning was conducted on March 13, 2023. D. Rust like residue on the (b) (4) and (b) (4) shaft were observed on product contact surface, of the (b) (4) area. The equipment completed a equipment # ZEN/MC/P-44 located in the Batch to Batch cleaning on March 13, 2023. E. Rust like residue on the inside and outside of the (b) (4) were observed on product contact surface of the (b) (4) located in the (b) (4) equipment # (b) (4) area. Both the equipment completed a Batch to Batch cleaning on March 25, 2023. F. On March 25 and 26, 2023, replicate swab samples of the residue from the cleaned, non-dedicated (b) (4) (equipment # (b) (4) (equipment # ZEN/MC/P-56), (b) (4) (ZEN/MC/P-44) and (b) (4) (equipment # (b) (4) were collected and analyzed for (b) (4) and (b) (4). The samples were analyzed on March 25 and 26, 2023. On March 26, 2023, the results of the analysis were as provided, and they are as follows: [illegible]
- Observation 2
Failure to investigate reruns and extra GC files
No investigations are conducted to evaluate all potential root causes of multiple sample results. Specifically, in reviewing your firm HPLC and GC computerized analytical data from 2021-2023, you failed to investigate the following: A. Three (3) separate analysis were rerun on HPLC equipment # QC/INST/09. 1. The first set of samples consisted of (b) (4) injections which were analyzed on December 7-8, 2021 for (b) (4) calibration. The injections were rerun due to wrong vial number. 2. The second set of samples consisted of (b) (4) injections and were analyzed on June 2, 2022 for (b) (4) stability of (b) (4). The injections were rerun due to wrong preparation of sample. 3. The third set of samples consisted of (b) (4) injections which were analyzed on February 5, 2023 for (b) (4) stability of (b) (4). The injections were rerun due to wrong column was used for analysis. According to Assistant QC Manager, the samples were reanalyzed due to analysist error and no investigation was conducted. B. According to a QC Officer, the Gas Chromatograph (equipment # QC/INST/09) sporadically generates more files than the actual analysis that is performed. Therefore, the analyst selects the (b) (4) samples that are generated from the analysis and uses the selected files as the final samples. The QC Officer added that they do not know why this occurs and when the extra files are generated, and no investigation was conducted for this occurrence(s).
Show observations 3 to 5
- Observation 3
Inadequate laboratory computer system access controls
Appropriate controls governing computer acquired data and/or related systems have not been established to assure that changes and access to computerized software for the laboratory control system is accessed only by authorized personnel. Specifically, on March 23 and 27, 2023, I observed, A. UV which uses software UV Probe 2.70 (equipment # QC/INST/13) does not have audit trail capabilities. This equipment is used for the identification of (b) (4) which is shipped to the US. B. GC which uses Chrome 2004 crt software (equipment # QC/INST/08) has a common user name and password shared by four (4) employees. The GC is used for analyzing the purity of solvents. C. HPLC which uses Chromeleon 6.80 software (equipment # QC/INST/09) has a user name "cmadmin" that is used by at least two (2) employees. This user name gives the employee the ability to change the rights of users; which includes the ability of data deletion. This equipment is used for Assay & impurity content for (b) (4) which is shipped to the US. D. Your firm's back up of electronic data is inadequate and does not conform to your firm's Data backup procedure QC/SOP/GEN/59, document titled, 'Standard Operating Procedure for Backup of Electronic Data', with issued date January 30, 2020. - Your firm uses unprotected portable hard drives to store electronic data for HPLC, GC and UV. - According to Administrator Manager / IT the electronic data that is backed up on to the portable hard drive is overridden each time a backup is conducted. The previous data is lost. - All backed up data are not verified by the Quality Department for its accuracy and the backup is not documented.
- Observation 4
Performance qualification not performed for equipment
Qualification of equipment were not performed. Specifically, Your firm failed to perform Performance Qualification (PQ) for equipment but not limited to (b) (4) equipment # ZEN/MC/P-56, (b) (4) equipment # (b) (4) equipment # ZEN/MC/P-44, (b) (4) (equipment # (b) (4). According to section 7.8.4 of your SOP, QA/SOP/GEN/39, document titled, 'Standard Operating Procedure for Qualification of Facility / Equipment's / System' states, that QA in coordination with user department and Engineering department shall conduct PQ.
- Observation 5
Employees untrained in cleaning procedures
Employees are not trained in cleaning procedures. Specifically, Your firm failed to train your employees who perform cleaning, verify that cleaning is adequate and recheck and approve cleaning equipment and sign final cleaning batch to batch or product to product documentation. In reviewing employee's training records, approximately six (6) employees were deficient in training on cleaning SOP, TR/15/05/013. During the inspection, six (6) equipment were found with product residue. This includes equipment such as the (b) (4) and (b) (4).
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on May 28, 2026.
Inspection ending Mar 28, 2023VAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Jun 4, 2025FDA-FOIA-2025-7209Form 483Records released
- Jan 22, 2025FDA-FOIA-2025-575EIRClosed
Inspection date not given
1 request. FDA released records in answer to a request for its Form 483 on Jun 4, 2026. FDAgent holds no copy that FDA posted.
- May 28, 2026FDA-FOIA-2026-5359Form 483· 1 of 2 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- Zen Chemicals Private LimitedD-U-N-S 871623684
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3015345351 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3015345351. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.