Zen Chemicals Pvt. Ltd Form 483, March 2023

FDA issued this Form 483 to Zen Chemicals Pvt. Ltd in Jalna, India (FEI 3015345351) at the end of a drug inspection that ended March 28, 2023. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 19, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Mar 28, 2023
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 19, 2026
1,301 days after the inspection
Facility
FEI 3015345351
Jalna, India

The 5 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Dirty non-dedicated equipment, no cleaning validation

    Equipment are not cleaned and sanitized to prevent contamination of the critical API intermediate product. Specifically, your firm failed to complete a clean and dirty hold time study and to establish clean and dirty hold times for (b) (4). Additionally, you failed to ensure that you are able to clean and remove the previous manufactured critical API intermediate with no carryover during changeover cleaning using non-dedicated equipment. On March 13 and 14, 2023, I observed, during the facility walkthrough, the following equipment used to manufacture U.S. marketed critical API intermediate were observed visibly dirty. This includes multiple critical API intermediate contact surfaces. All equipment noted below were in a cleaned state during my visual observation and are non-dedicated. In addition, you do not perform a cleaning verification (e.g. swabbing) of the equipment after material changeover cleaning. A. (b) (4) residue on the inside of the (b) (4) and (b) (4) as well as (b) (4) and (b) (4) residues on the corner of the (b) (4) were observed on product contact surface, the inside side of the equipment # ZEN/MC/P-56 located in the (b) (4) area. Batch to Batch cleaning was conducted on March 14, 2023. B. (b) (4) residue in the (b) (4) and (b) (4) below the bowl of the (b) (4) residue in (b) (4) and (b) (4) and (b) (4) were observed on the (b) (4) of the equipment # ZEN/MC/P-31 located in the (b) (4) area. Batch to Batch cleaning was conducted on March 13, 2023. C. (b) (4) residue around the circumference of the bowl of the (b) (4) were observed on the (b) (4) equipment # ZEN/MC/P-62 located in the (b) (4) area. Batch to Batch cleaning was conducted on March 13, 2023. D. Rust like residue on the (b) (4) and (b) (4) shaft were observed on product contact surface, of the (b) (4) area. The equipment completed a equipment # ZEN/MC/P-44 located in the Batch to Batch cleaning on March 13, 2023. E. Rust like residue on the inside and outside of the (b) (4) were observed on product contact surface of the (b) (4) located in the (b) (4) equipment # (b) (4) area. Both the equipment completed a Batch to Batch cleaning on March 25, 2023. F. On March 25 and 26, 2023, replicate swab samples of the residue from the cleaned, non-dedicated (b) (4) (equipment # (b) (4) (equipment # ZEN/MC/P-56), (b) (4) (ZEN/MC/P-44) and (b) (4) (equipment # (b) (4) were collected and analyzed for (b) (4) and (b) (4). The samples were analyzed on March 25 and 26, 2023. On March 26, 2023, the results of the analysis were as provided, and they are as follows: [illegible]

  2. 2

    Failure to investigate reruns and extra GC files

    No investigations are conducted to evaluate all potential root causes of multiple sample results. Specifically, in reviewing your firm HPLC and GC computerized analytical data from 2021-2023, you failed to investigate the following: A. Three (3) separate analysis were rerun on HPLC equipment # QC/INST/09. 1. The first set of samples consisted of (b) (4) injections which were analyzed on December 7-8, 2021 for (b) (4) calibration. The injections were rerun due to wrong vial number. 2. The second set of samples consisted of (b) (4) injections and were analyzed on June 2, 2022 for (b) (4) stability of (b) (4). The injections were rerun due to wrong preparation of sample. 3. The third set of samples consisted of (b) (4) injections which were analyzed on February 5, 2023 for (b) (4) stability of (b) (4). The injections were rerun due to wrong column was used for analysis. According to Assistant QC Manager, the samples were reanalyzed due to analysist error and no investigation was conducted. B. According to a QC Officer, the Gas Chromatograph (equipment # QC/INST/09) sporadically generates more files than the actual analysis that is performed. Therefore, the analyst selects the (b) (4) samples that are generated from the analysis and uses the selected files as the final samples. The QC Officer added that they do not know why this occurs and when the extra files are generated, and no investigation was conducted for this occurrence(s).

  3. 3

    Inadequate laboratory computer system access controls

    Appropriate controls governing computer acquired data and/or related systems have not been established to assure that changes and access to computerized software for the laboratory control system is accessed only by authorized personnel. Specifically, on March 23 and 27, 2023, I observed, A. UV which uses software UV Probe 2.70 (equipment # QC/INST/13) does not have audit trail capabilities. This equipment is used for the identification of (b) (4) which is shipped to the US. B. GC which uses Chrome 2004 crt software (equipment # QC/INST/08) has a common user name and password shared by four (4) employees. The GC is used for analyzing the purity of solvents. C. HPLC which uses Chromeleon 6.80 software (equipment # QC/INST/09) has a user name "cmadmin" that is used by at least two (2) employees. This user name gives the employee the ability to change the rights of users; which includes the ability of data deletion. This equipment is used for Assay & impurity content for (b) (4) which is shipped to the US. D. Your firm's back up of electronic data is inadequate and does not conform to your firm's Data backup procedure QC/SOP/GEN/59, document titled, 'Standard Operating Procedure for Backup of Electronic Data', with issued date January 30, 2020. - Your firm uses unprotected portable hard drives to store electronic data for HPLC, GC and UV. - According to Administrator Manager / IT the electronic data that is backed up on to the portable hard drive is overridden each time a backup is conducted. The previous data is lost. - All backed up data are not verified by the Quality Department for its accuracy and the backup is not documented.

  4. 4

    Performance qualification not performed for equipment

    Qualification of equipment were not performed. Specifically, Your firm failed to perform Performance Qualification (PQ) for equipment but not limited to (b) (4) equipment # ZEN/MC/P-56, (b) (4) equipment # (b) (4) equipment # ZEN/MC/P-44, (b) (4) (equipment # (b) (4). According to section 7.8.4 of your SOP, QA/SOP/GEN/39, document titled, 'Standard Operating Procedure for Qualification of Facility / Equipment's / System' states, that QA in coordination with user department and Engineering department shall conduct PQ.

  5. 5

    Employees untrained in cleaning procedures

    Employees are not trained in cleaning procedures. Specifically, Your firm failed to train your employees who perform cleaning, verify that cleaning is adequate and recheck and approve cleaning equipment and sign final cleaning batch to batch or product to product documentation. In reviewing employee's training records, approximately six (6) employees were deficient in training on cleaning SOP, TR/15/05/013. During the inspection, six (6) equipment were found with product residue. This includes equipment such as the (b) (4) and (b) (4).

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.