Samsung Biologics Co. Ltd. Form 483, September 2023

FDA issued this Form 483 to Samsung Biologics Co. Ltd. in Yeonsu District, Korea (the Republic of) (FEI 3010479596) at the end of a drug inspection that ended September 1, 2023. It lists 6 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 17, 2023. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Sep 1, 2023
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 17, 2023
46 days after the inspection
Facility
FEI 3010479596
Yeonsu District, Korea (the Republic of)

The 6 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate data integrity controls in MSAT lab

    The Manufacturing Scientific Analytical Technology (MSAT) laboratory used in support of application submission testing data had inadequate controls over data integrity. Specifically, A) The MSAT laboratory was used in support of application submission data for (b) (4) and (b) (4) with the laboratory a development laboratory having inadequate controls in assurance of data integrity since 2013. Although you conducted an internal data integrity assessment for each application, with completion of the assessments conducted during the inspection period, there is no means of determining with absolute certainty the true reliability of all test data, with a third-party independent assessment of the test data not performed. B) An assessment to determine how the use of the MSAT lab in support of submission data to the Agency affects already commercially marketed products has not been completed. Data integrity deficiencies were identified in DEV-010168, which included, but is not limited to, shared administration passwords, lack of data backup, and lack of audit trails. This laboratory was identified as being used to generate data which was submitted to the Agency in support of currently approved drug products for (b) (4) (b) (4) C) Under Deviation Report 010168, Failure to correct integrity gaps and inappropriate GMP practices in the MSAT Laboratory, you indicate the first internal audit of the MSAT Laboratory was (b) (4) as an ad-hoc audit (SIR(b) (4) 05), and while no data integrity issues were identified, a recommendation to implement good documentation practice and data verification procedures was identified. At the request of Senior Quality Management, a subsequent audit was performed (b) (4) (SIR-(b) -05), based on laboratory areas of work that included GMP requirements (e.g., support of regulatory submissions), with a critical observation pertaining to shared administration accounts and lack of data backup. Corrective action for shared accounts included the introduction of equipment logbooks to guarantee the minimum documentation requirements, with improper implementation. An audit (SIR(b) (4) -06) of the laboratory was conducted again on (b) (4) with observations found in 2021 similarly found again, excluding logbooks. Although you opened CAPAs in response to the (b) (4) audit, the scope of the remediation plan did not fully assess data integrity gaps, focusing solely on traceability of equipment users, with no action taken for shared administrative passwords. You received observations and recommendations from a client audit 06 July 2022 and 01 September 2022 specific to the MSAT Laboratory data management practices, with Samsung senior executive tour of the MSAT Laboratory 14 September 2022 identifying sticky notes with system password written on PCs, use of shared administration account, no label on chemical solutions, uncontrolled spreadsheets used to track samples, use of uncontrolled sheets to document test results, poor housekeeping of the laboratories, and safety issues. The same similar findings were reported through the MSAT internal audits conducted (b) (4) (SIR(b) (4) -05) and (b) (b) (4) (SIR(b) (4) 06). You failed to address laboratory deficiencies in a timely manner in assurance of data quality, data integrity used in regulatory submissions. You further failed to notify clients in a timely manner, where the MSAT laboratory deficiency was identified in September 2022, with dates of client notification ranging from 17 October 2022 to 16 January 2023.

  2. 2

    Production and process control procedures deficient

    Written production and process control procedures are not followed, established, or are deficient. Specifically, A) On 25 August 2023, observed for Plant (b) (4) RABS Fill Line (b) (4) Batch #(b) (4) was the transition of the (b) (4) stopper bowl from Grade B space into the Grade A RABS. Furthermore, observed was the transition of a (b) (4) system from Grade B space to the Grade A RABS, where the (b) (4) bag was opened in Grade B space, with the (b) (4) bag transitioning into the Grade A RABS. In both fill line setup activities, a portion of the (b) (4) bag entered the RABS Grade A space. On 30 August 2023, a similar observation was made during a review of the Fill Line (b) RABS smoke pattern video under GENP-02057. Observed was the opening of the (b) (4) bagged stopper bowl in Grade B space, with the (b) (4) bag transitioning to the RABS Grade A space that included a majority of the (b) (4) bag. SOP-MFE-00293, "Operation and Maintenance of (b) (4) Drug Product Vial Fill Machine", v40.0, Effective date 29 August 2023 fails to provide adequate instruction for transition of (b) (4) bagged sterilized equipment from Grade B space to the Grade A RABS, where the (b) (4) bag should remain in Grade B space. You indicated that the smoke pattern video is reviewed and approved by quality, with the video used for training of fill line operators for proper RABS setup, aseptic technique. B) Video recordings of media fill runs are not always retained. Procedure: SOP-MFP-00164, "Process Simulation for Drug Product" version: 37, Effective Date: 28-July-2023, states all personnel involved in aseptic operations will review excerpts of media fill video with Quality and Operations management and that any poor aseptic technique identified are discussed and provided remedial training to rectify poor aseptic technique. The videos for media fills dated 22-June-2021 (batch (b) (4) and 23-June-2021 (batch (b) (4) are no longer kept by the firm and are not available for viewing. C) Your procedure, MET-00018, "Quantitation of Viable Microorganisms by Contact Plates", Effective Date 07/08/2023, version 43.0 Section 8.2.1.9 states "For personnel gloves monitoring, using Finger Dab Method - Aseptically open the contact plate and place his/her fingers with the glove gently on the media surface of one (1) contact plate (dabbing four (4) finger pads on (b) (4) and then rolling motion of thumb ensuring the entire pad of the thumb touches the surface of the media)". On 23-Aug-2023, we observed two of your aseptic operators fail to follow your procedure for fingertip personnel monitoring. Operators were observed testing the tips of their fingers instead of their finger pads during the aseptic filling of sterile injectable drug product, (b) (4) Lot (b) (4) D) On 24 August 2023, observed was the (b) (4) drug substance fill process, batch (b) (4) into (b) (4) liter bottles by closed filling system. According to SOP-MFP-00074, "Inspection of Process Equipment and Materials", v22, Effective date 08 August 2023, Section 8.1 includes visually inspect materials, probes, parts, and assemblies before use or installation and verify that it is integral and free of debris, surface anomalies, foreign residue, or defects. Observed was no visual inspection of the drug substance container closure systems for absence of defect or debris within each bottle that could have an impact on product quality, with the standard operating procedure not followed. There is no documentation requirement for the drug substance container closure system visual inspection. E) According to SOP-MFE-00280, "Recipe and Preparation for Sterilization using DP (b) (4), v49.0, Effective date 25/08/2023, Section 7.7 includes inspection for sterilization, check the (b) (4) of (b) (4) items while unloading the (b) (4) items onto the cart and/or shelf. The procedure fails to include at a minimum the rejection of the (b) (4) load if observed (b) (4) F) SOP-QC-00130, "Assay Performance Monitoring" (ver. 15.0, effe

    Shortened here; the PDF has the full text.

  3. 3

    Inadequate manufacturing operation and process controls

    Controls over manufacturing operations and process have not been adequately established. Specifically, A) Airflow visualization studies have not been performed for all interventions as required by procedure: SOP-MFP-00206, "Airflow Visualization Evaluation", Version: 8.0, Effective Date: 26-June-2023. The removal of jammed vials at the (b) (4) and the removal, adjustment/maintenance, and re-installation of the (b) (4) (b) (4) have not been evaluated as part of smoke studies. B) Fill Line (b) for (b) (4) drug product manufacture includes a (b) (4) vial conveying system, where (b) (4) vials filled with drug product can be filled and pending stoppering during a line stoppage. There is no procedure or HMI limitation for how long product filled vials can be exposed to the filling environment pending stoppering nor is there a requirement for a time-period to be assessed by media fill. Your Quality Risk Assessment fails to assess the said condition and impact on product quality. C) MBR-00570, MBR-573, and MBR-00934 do not clearly describe the frequency of the visual inspection for bioreactor surface followed by (b) (4) for the following unit operations: (b) (4) Operation of (b) (4)L Bioreactor, (b) (4) Operation of (b) (4)L Bioreactor, and (b) (4) Operation of (b) (4)L Bioreactor.

  4. 4

    Equipment revalidation not performed at intervals

    Revalidation of equipment used in the processing of drug product is not performed at appropriate intervals. Specifically, A) Your firm's Quality Unit failed to ensure equipment is maintained and used within its validated state. For example: (b) (4) ID 130-(b) (4)-5311: Was due on 01-Jul-2022. However, the equipment was not revalidated until 21-Sep-2022. Your firm produced (b) (4) batches using items that were (b) (4) within this time using this equipment. (b) (4) ID 130-(b) (4)-3220: Was due on 02-Dec-2021. However, the equipment was not revalidated until 16-Feb-2022. Your firm produced (b) (4) batches using items that were (b) (4) within this time using this equipment. (b) (4) ID 130-(b) (4)-3210: Was due on 02-Dec-2021. However, the equipment was not revalidated until 03-Jan-2022. Your firm produced (b) (4) batch using items that were (b) (4) within this time using this equipment. -HPLC ID 150-HPLC-001: Was due for revalidation (b) (4) from the last revalidation which was performed on 20-Aug-2023. However, this equipment was observed being used past its revalidation due date. -HPLC 150-HPLC-006: Was due for revalidation (b) (4) from the last revalidation which was performed on 16-Aug-2023. However, this equipment was observed being used past its revalidation due date. -ELISA Binding ID 150-FACS-003: Was due for revalidation (b) (4) from the last revalidation which was performed on 03-Aug-2023. However, this equipment was observed being used past its revalidation due date. Your firm stated the equipment were not revalidated due to their respective grace periods granted by your procedure SOP-VAL-00016, Revalidation Program, Effective date: 07-Jul-2023, Version 51.0; however, you were unable to provide scientific justification to support the grace period. B) (b) (4) 230-(b) (4)-5311 used in Plant (b) for (b) (4) sterilization of equipment and components for Fill Line (b) includes a (b) (4) supplied with (b) (4) with the last (b) (4) sterilization process validated both physically and biologically, June 2020. The (b) (4) is not revalidated on a routine basis in assurance the validated state is maintained.

  5. 5

    Inadequate Quality Unit oversight and investigations

    The Quality Unit is inadequate to ensure it is capable of carrying out it's roles and responsibilities. For example: A) The Quality Unit has not ensured quality records such as deviations and non-conformance investigations are closed within their respective due dates. Between Quarter 1 2022 and Quarter 2 2023 the average amount of overdue deviation and non-conformance investigations were 10% and 18%, respectively. B) SOP-QC-00105, "Invalid Assay Procedure" (ver. 22.0, effective on August 18, 2023) allows for up to (b) (4) consecutive failures for the same sample for select methods. Multiple invalid runs, including consecutive runs (high invalid assay rate), were reported for (b) (4) and (b) (4) (MET-00274 - (b)%) and for (b) (MET-00717 - (b)% and MET-00718 - (b)%). In addition, laboratory investigations for SST failures did not identify abnormalities using PEMME (people, equipment, method, material, environment) tool and investigations concluded that invalidation rate will be monitored continuously since root cause of invalid runs was not identified. This is a repeat observation as high invalid rates were previously observed during FDA inspection of the facility in 2022 and corrective actions implemented by the firm appear not effective. C) Investigations opened to review environmental monitoring in which sterile drug products are filled are inadequate. For example, your firm opened deviation DEV-010542 due to a recovery of Paenibacillus glucanolyticus a spore forming microorganism during the filling of sterile drug product, (b) (4) Lot (b) (4) However, your firm failed to extend the investigation to other personnel involved in the filling of this drug to ensure the interventions performed by other personnel did not impact the sterility of the drug product. Additionally, during the inspection, we observed that personnel monitoring is not performed according to your procedure. See OBSERVATION 2C.

  6. 6

    Facilities not adequately maintained

    Facilities are not adequately maintained. Specifically, A) On 25 August 2023, observed was a ceiling port cover dislodged in Grade B space, directly over where Plant (b)(4) (Fill Line (b)(4) RABS (b) (4) open. The condition was observed during fill line setup for manufacture of (b) (4) Batch #(b) (4) B) On 21 August 2023, observed within the GMP warehouse, Solid Waste Collection WI-1130 was a door leading to the outside, with the door bottom damaged. Furthermore, in Office Supply WI-1131, a floor receiving and loading ramp dock mechanism was missing a seal. Each condition is a potential entry point for pests to enter the facility. C) On 21 August 2023, a deteriorated sealant between floor and wall was observed in (b) (4) Preparation room (b) (4) in Plant (b)

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3010479596, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.