Skip to content

Samsung Biologics Co., Ltd.

300 Songdobaiodae-Ro, Yeonsu District, Korea (the Republic of)

FEI 3010479596DUNS 963366985

Company: Samsung Biologics Co., Ltd. · Linked by exact D-U-N-S match (557810567) in FDA registration data

FDA has 4 inspections on file for Samsung Biologics Co., Ltd. in Yeonsu District, Korea (the Republic of) (FEI 3010479596), from 2018 to 2023. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated May 27, 2025 that FDAgent has not matched to an inspection on the Data Dashboard.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. One of the 10 FOIA requests for this site has asked FDA for this inspection's 483, and four more for the 483 from a later inspection, ending May 27, 2025, that FDA's Data Dashboard doesn't list yet.

3 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Samsung Biologics Co., Ltd. (D-U-N-S 557810567), has registered 1 other site.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
4, 2018–2023
0 OAI · 4 VAI · 0 NAI
Inspections with 483 observations shown
2 of 4
4 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
5 posted
Requested under FOIA
10 requests, latest FY2023
Warning letters
None on file
Import refusals
3 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate data integrity controls in MSAT lab

      The Manufacturing Scientific Analytical Technology (MSAT) laboratory used in support of application submission testing data had inadequate controls over data integrity. Specifically, A) The MSAT laboratory was used in support of application submission data for (b) (4) and (b) (4) with the laboratory a development laboratory having inadequate controls in assurance of data integrity since 2013. Although you conducted an internal data integrity assessment for each application, with completion of the assessments conducted during the inspection period, there is no means of determining with absolute certainty the true reliability of all test data, with a third-party independent assessment of the test data not performed. B) An assessment to determine how the use of the MSAT lab in support of submission data to the Agency affects already commercially marketed products has not been completed. Data integrity deficiencies were identified in DEV-010168, which included, but is not limited to, shared administration passwords, lack of data backup, and lack of audit trails. This laboratory was identified as being used to generate data which was submitted to the Agency in support of currently approved drug products for (b) (4) (b) (4) C) Under Deviation Report 010168, Failure to correct integrity gaps and inappropriate GMP practices in the MSAT Laboratory, you indicate the first internal audit of the MSAT Laboratory was (b) (4) as an ad-hoc audit (SIR(b) (4) 05), and while no data integrity issues were identified, a recommendation to implement good documentation practice and data verification procedures was identified. At the request of Senior Quality Management, a subsequent audit was performed (b) (4) (SIR-(b) -05), based on laboratory areas of work that included GMP requirements (e.g., support of regulatory submissions), with a critical observation pertaining to shared administration accounts and lack of data backup. Corrective action for shared accounts included the introduction of equipment logbooks to guarantee the minimum documentation requirements, with improper implementation. An audit (SIR(b) (4) -06) of the laboratory was conducted again on (b) (4) with observations found in 2021 similarly found again, excluding logbooks. Although you opened CAPAs in response to the (b) (4) audit, the scope of the remediation plan did not fully assess data integrity gaps, focusing solely on traceability of equipment users, with no action taken for shared administrative passwords. You received observations and recommendations from a client audit 06 July 2022 and 01 September 2022 specific to the MSAT Laboratory data management practices, with Samsung senior executive tour of the MSAT Laboratory 14 September 2022 identifying sticky notes with system password written on PCs, use of shared administration account, no label on chemical solutions, uncontrolled spreadsheets used to track samples, use of uncontrolled sheets to document test results, poor housekeeping of the laboratories, and safety issues. The same similar findings were reported through the MSAT internal audits conducted (b) (4) (SIR(b) (4) -05) and (b) (b) (4) (SIR(b) (4) 06). You failed to address laboratory deficiencies in a timely manner in assurance of data quality, data integrity used in regulatory submissions. You further failed to notify clients in a timely manner, where the MSAT laboratory deficiency was identified in September 2022, with dates of client notification ranging from 17 October 2022 to 16 January 2023.

    2. Observation 2

      Production and process control procedures deficient

      Written production and process control procedures are not followed, established, or are deficient. Specifically, A) On 25 August 2023, observed for Plant (b) (4) RABS Fill Line (b) (4) Batch #(b) (4) was the transition of the (b) (4) stopper bowl from Grade B space into the Grade A RABS. Furthermore, observed was the transition of a (b) (4) system from Grade B space to the Grade A RABS, where the (b) (4) bag was opened in Grade B space, with the (b) (4) bag transitioning into the Grade A RABS. In both fill line setup activities, a portion of the (b) (4) bag entered the RABS Grade A space. On 30 August 2023, a similar observation was made during a review of the Fill Line (b) RABS smoke pattern video under GENP-02057. Observed was the opening of the (b) (4) bagged stopper bowl in Grade B space, with the (b) (4) bag transitioning to the RABS Grade A space that included a majority of the (b) (4) bag. SOP-MFE-00293, "Operation and Maintenance of (b) (4) Drug Product Vial Fill Machine", v40.0, Effective date 29 August 2023 fails to provide adequate instruction for transition of (b) (4) bagged sterilized equipment from Grade B space to the Grade A RABS, where the (b) (4) bag should remain in Grade B space. You indicated that the smoke pattern video is reviewed and approved by quality, with the video used for training of fill line operators for proper RABS setup, aseptic technique. B) Video recordings of media fill runs are not always retained. Procedure: SOP-MFP-00164, "Process Simulation for Drug Product" version: 37, Effective Date: 28-July-2023, states all personnel involved in aseptic operations will review excerpts of media fill video with Quality and Operations management and that any poor aseptic technique identified are discussed and provided remedial training to rectify poor aseptic technique. The videos for media fills dated 22-June-2021 (batch (b) (4) and 23-June-2021 (batch (b) (4) are no longer kept by the firm and are not available for viewing. C) Your procedure, MET-00018, "Quantitation of Viable Microorganisms by Contact Plates", Effective Date 07/08/2023, version 43.0 Section 8.2.1.9 states "For personnel gloves monitoring, using Finger Dab Method - Aseptically open the contact plate and place his/her fingers with the glove gently on the media surface of one (1) contact plate (dabbing four (4) finger pads on (b) (4) and then rolling motion of thumb ensuring the entire pad of the thumb touches the surface of the media)". On 23-Aug-2023, we observed two of your aseptic operators fail to follow your procedure for fingertip personnel monitoring. Operators were observed testing the tips of their fingers instead of their finger pads during the aseptic filling of sterile injectable drug product, (b) (4) Lot (b) (4) D) On 24 August 2023, observed was the (b) (4) drug substance fill process, batch (b) (4) into (b) (4) liter bottles by closed filling system. According to SOP-MFP-00074, "Inspection of Process Equipment and Materials", v22, Effective date 08 August 2023, Section 8.1 includes visually inspect materials, probes, parts, and assemblies before use or installation and verify that it is integral and free of debris, surface anomalies, foreign residue, or defects. Observed was no visual inspection of the drug substance container closure systems for absence of defect or debris within each bottle that could have an impact on product quality, with the standard operating procedure not followed. There is no documentation requirement for the drug substance container closure system visual inspection. E) According to SOP-MFE-00280, "Recipe and Preparation for Sterilization using DP (b) (4), v49.0, Effective date 25/08/2023, Section 7.7 includes inspection for sterilization, check the (b) (4) of (b) (4) items while unloading the (b) (4) items onto the cart and/or shelf. The procedure fails to include at a minimum the rejection of the (b) (4) load if observed (b) (4) F) SOP-QC-00130, "Assay Performance Monitoring" (ver. 15.0, effe

      Shortened here; the PDF has the full text.

    Show observations 3 to 6
    1. Observation 3

      Inadequate manufacturing operation and process controls

      Controls over manufacturing operations and process have not been adequately established. Specifically, A) Airflow visualization studies have not been performed for all interventions as required by procedure: SOP-MFP-00206, "Airflow Visualization Evaluation", Version: 8.0, Effective Date: 26-June-2023. The removal of jammed vials at the (b) (4) and the removal, adjustment/maintenance, and re-installation of the (b) (4) (b) (4) have not been evaluated as part of smoke studies. B) Fill Line (b) for (b) (4) drug product manufacture includes a (b) (4) vial conveying system, where (b) (4) vials filled with drug product can be filled and pending stoppering during a line stoppage. There is no procedure or HMI limitation for how long product filled vials can be exposed to the filling environment pending stoppering nor is there a requirement for a time-period to be assessed by media fill. Your Quality Risk Assessment fails to assess the said condition and impact on product quality. C) MBR-00570, MBR-573, and MBR-00934 do not clearly describe the frequency of the visual inspection for bioreactor surface followed by (b) (4) for the following unit operations: (b) (4) Operation of (b) (4)L Bioreactor, (b) (4) Operation of (b) (4)L Bioreactor, and (b) (4) Operation of (b) (4)L Bioreactor.

    2. Observation 4

      Equipment revalidation not performed at intervals

      Revalidation of equipment used in the processing of drug product is not performed at appropriate intervals. Specifically, A) Your firm's Quality Unit failed to ensure equipment is maintained and used within its validated state. For example: (b) (4) ID 130-(b) (4)-5311: Was due on 01-Jul-2022. However, the equipment was not revalidated until 21-Sep-2022. Your firm produced (b) (4) batches using items that were (b) (4) within this time using this equipment. (b) (4) ID 130-(b) (4)-3220: Was due on 02-Dec-2021. However, the equipment was not revalidated until 16-Feb-2022. Your firm produced (b) (4) batches using items that were (b) (4) within this time using this equipment. (b) (4) ID 130-(b) (4)-3210: Was due on 02-Dec-2021. However, the equipment was not revalidated until 03-Jan-2022. Your firm produced (b) (4) batch using items that were (b) (4) within this time using this equipment. -HPLC ID 150-HPLC-001: Was due for revalidation (b) (4) from the last revalidation which was performed on 20-Aug-2023. However, this equipment was observed being used past its revalidation due date. -HPLC 150-HPLC-006: Was due for revalidation (b) (4) from the last revalidation which was performed on 16-Aug-2023. However, this equipment was observed being used past its revalidation due date. -ELISA Binding ID 150-FACS-003: Was due for revalidation (b) (4) from the last revalidation which was performed on 03-Aug-2023. However, this equipment was observed being used past its revalidation due date. Your firm stated the equipment were not revalidated due to their respective grace periods granted by your procedure SOP-VAL-00016, Revalidation Program, Effective date: 07-Jul-2023, Version 51.0; however, you were unable to provide scientific justification to support the grace period. B) (b) (4) 230-(b) (4)-5311 used in Plant (b) for (b) (4) sterilization of equipment and components for Fill Line (b) includes a (b) (4) supplied with (b) (4) with the last (b) (4) sterilization process validated both physically and biologically, June 2020. The (b) (4) is not revalidated on a routine basis in assurance the validated state is maintained.

    3. Observation 5

      Inadequate Quality Unit oversight and investigations

      The Quality Unit is inadequate to ensure it is capable of carrying out it's roles and responsibilities. For example: A) The Quality Unit has not ensured quality records such as deviations and non-conformance investigations are closed within their respective due dates. Between Quarter 1 2022 and Quarter 2 2023 the average amount of overdue deviation and non-conformance investigations were 10% and 18%, respectively. B) SOP-QC-00105, "Invalid Assay Procedure" (ver. 22.0, effective on August 18, 2023) allows for up to (b) (4) consecutive failures for the same sample for select methods. Multiple invalid runs, including consecutive runs (high invalid assay rate), were reported for (b) (4) and (b) (4) (MET-00274 - (b)%) and for (b) (MET-00717 - (b)% and MET-00718 - (b)%). In addition, laboratory investigations for SST failures did not identify abnormalities using PEMME (people, equipment, method, material, environment) tool and investigations concluded that invalidation rate will be monitored continuously since root cause of invalid runs was not identified. This is a repeat observation as high invalid rates were previously observed during FDA inspection of the facility in 2022 and corrective actions implemented by the firm appear not effective. C) Investigations opened to review environmental monitoring in which sterile drug products are filled are inadequate. For example, your firm opened deviation DEV-010542 due to a recovery of Paenibacillus glucanolyticus a spore forming microorganism during the filling of sterile drug product, (b) (4) Lot (b) (4) However, your firm failed to extend the investigation to other personnel involved in the filling of this drug to ensure the interventions performed by other personnel did not impact the sterility of the drug product. Additionally, during the inspection, we observed that personnel monitoring is not performed according to your procedure. See OBSERVATION 2C.

    4. Observation 6

      Facilities not adequately maintained

      Facilities are not adequately maintained. Specifically, A) On 25 August 2023, observed was a ceiling port cover dislodged in Grade B space, directly over where Plant (b)(4) (Fill Line (b)(4) RABS (b) (4) open. The condition was observed during fill line setup for manufacture of (b) (4) Batch #(b) (4) B) On 21 August 2023, observed within the GMP warehouse, Solid Waste Collection WI-1130 was a door leading to the outside, with the door bottom damaged. Furthermore, in Office Supply WI-1131, a floor receiving and loading ramp dock mechanism was missing a seal. Each condition is a potential entry point for pests to enter the facility. C) On 21 August 2023, a deteriorated sealant between floor and wall was observed in (b) (4) Preparation room (b) (4) in Plant (b)

  3. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not recorded and justified.

  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  8. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

10 requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.

  • Inspection ending May 27, 2025

    4 requests. Not listed in FDA’s Data Dashboard yet. FDA has posted its Form 483.

    1. Sep 22, 2025FDA-FOIA-2025-11141Form 483Records released
    2. Jul 31, 2025FDA-FOIA-2025-9283Form 483Records released
    3. Jul 25, 2025FDA-FOIA-2025-9104Form 483· 1 of 2 sitesRecords released
    4. Date not givenFDA-FOIA-2026-4305Form 483· 1 of 14 sitesRecords released
  • Inspection ending Sep 1, 2023VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Feb 2, 2024FDA-FOIA-2024-1167Form 483Closed
  • Inspection ending Feb 28, 2023VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jan 12, 2024FDA-FOIA-2024-405Form 483Closed
  • Inspection ending Jun 9, 2022

    2 requests. Not listed in FDA’s Data Dashboard yet. FDA has posted its Form 483.

    1. FY2023FDA-FOIA-2023-19Form 483No records found
    2. Sep 1, 2022FDA-FOIA-2022-6336Form 483Closed
  • Inspection date not given

    2 requests. None of FDA’s log entries for these requests say records were released.

    1. May 30, 2025FDA-FOIA-2025-7022Form 483Withdrawn
    2. Aug 5, 2024FDA-FOIA-2024-6973Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 1 section of 21 CFR in FDA’s published citations for 1 of this facility’s 4 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3010479596, one row per refused product line.

3 refusals from 2022-09-16 to 2025-11-04 · charged DIRSEXMPT on 2, FRNMFGREG on 1 · no FDA sample analysis

FDA firm profile
  • 2025-11-04

    ADALIMUMAB-BWWD58SCP01

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of West Coast ImportsNUV-3855286-8/70002/1

  • 2023-06-21

    MONOCLONAL ANTIBODIES, N.E.C.64OCK99

    DIRSEXMPT 502(f)(1), 801(a)(3); MISBRANDING

    Division of Northern Border Imports788-1799197-5/11/1

  • 2022-09-16

    MONOCLONAL ANTIBODIES, N.E.C.64OCK99

    DIRSEXMPT 502(f)(1), 801(a)(3); MISBRANDING

    Division of Northern Border Imports788-1775925-7/11/1

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
Samsung Biologics Co., Ltd.D-U-N-S 557810567

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Samsung Biologics Co., Ltd. (D-U-N-S 557810567) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3010479596 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3010479596. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.