Equipment cleaning and cleaning validation in FDA Form 483 observations
Cleaning procedures for manufacturing equipment, the studies that show they work, and the residues, swabs and logs that prove each cleaning. FDAgent finds 197 such observations in 144 Form 483s issued to 138 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 197
- Each quoted below
- Form 483s
- 144
- Posted by FDA
- Facilities
- 138
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 63 in 2026
| Year | Observations |
|---|---|
| 2008 | 1 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 0 |
| 2013 | 0 |
| 2014 | 1 |
| 2015 | 1 |
| 2016 | 10 |
| 2017 | 15 |
| 2018 | 20 |
| 2019 | 5 |
| 2020 | 5 |
| 2021 | 10 |
| 2022 | 7 |
| 2023 | 22 |
| 2024 | 13 |
| 2025 | 24 |
| 2026 | 63 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
The same entries the equipment cleaning topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“cleaning validat*” · “validat* … cleaning” · “cleaning procedure*” · “cleaning process*” · “cleaning record*” · “cleaning log*” · “cleaning agent*” · “cleaning verification” · “cleaning stud*” · “cleaning method*” · “cleaning effectiveness” · “not cleaned” · “not adequately cleaned” · “not properly cleaned” · “residue*” · “swab*” · “carry over” · “carryover”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 197 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Genlbet Biopbarmaceuticals SAInspection ended Jan 31, 2023 · FEI 3011160795 · Observation 3
Decontamination is incomplete or not adequately demonstrated to ensure prevention of cross-contamination. Specifically: a. A decontamination study was not performed to evaluate the effectiveness of [illegible] which is used to (b)(4) decontaminate [illegible] parts, against (b)(4). b. (b)(4), Report on the Cleaning Validation Strategy and Results did not evaluate the material of construction of all equipment or materials including (b)(4) (b)(4) …
Contains “cleaning validat*”Read the Form 483 →
Genlbet Biopbarmaceuticals SAInspection ended Jan 31, 2023 · FEI 3011160795 · Observation 4
Written procedures for decontamination, cleaning, and maintenance of equipment are deficient regarding sufficient details to protect equipment from contamination prior to use. For example: a. (b)(4) (b)(4) do not specify the duration that equipment may be exposed to the environment after cleaning (b)(4). b. (b)(4), Cleaning Validation Summary Report, does not specify how the hold time is determined. c. Protocols governing decontamination of …
Contains “cleaning validat*”Read the Form 483 →
Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 5
The aseptic fill lines in (b) (4) include the use of (b) (4) (b) (4) that assist to diffuse the HEPA filter air into the Grade A (b) (4) of the RABS. The Vice President Sterile Manufacturing & Operations confirmed that the (b) (4) are not cleaned and sanitized.
Contains “not cleaned”Read the Form 483 →
Octapharma Pharmazeutika Produktionsgesellschaft m.b.H. OPGInspection ended Dec 16, 2022 · FEI 3002809097 · Observation 1
… Cleaning and plant (b)(4) occurs after this (b)(4) plant (b)(4) Cleaning validations are not assured as accurate and continuously valid as environmental (b)(4) are not collected and tested for during the plant (b)(4) period. B. The firm's (b)(4) control management is inadequate. The firm is not in control of the (b)(4) management data, this is managed by the (b)(4) and is available in a read only manner but the firm is not trending the locations …
Contains “cleaning validat*”Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 1
… and does not extend to other batches previously manufactured after the aseptic filling of (b)(4) which could have been potentially affected by the inadequate cleaning procedure. The investigation did not question how (b)(4) could have potentially contaminated non-product contact equipment which lies above the filling line. Action REC 546084 was initiated on 6/15/22 to change cleaning method. A-SOP-21-01-056 Filling Line Disassembly and (b)(4) …
Contains “cleaning procedure*”Read the Form 483 →
Zhejiang Tianyu Pharmaceutical Co. Ltd.Inspection ended Mar 4, 2022 · FEI 3010972581 · Observation 2
… c) The initial risk assessment of !tiH•i approved on 09/23/2020 was not assessed for the potential carryover of impurities from the starting materials, !fH•i Your firm has received at [illegible] least one (1) complaint for the presence of [illegible] between [illegible] (manufacturing start date) and November 2021 (complaint date).
Contains “carryover”Read the Form 483 →
Zhejiang Tianyu Pharmaceutical Co. Ltd.Inspection ended Mar 4, 2022 · FEI 3010972581 · Observation 3
OBSERVATION 3 (Facilities and Equipment System) Equipment and utensils are not cleaned or maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, There is no assurance that your firm's production equipment is properly maintained in order to prevent it from becoming a potential source of contamination for the manufactured products from this …
Contains “not cleaned”Read the Form 483 →
Davis City Pharmacy Inc.Inspection ended Feb 18, 2022 · FEI 3016774626 · Observation 1
… There is no scientific justification and/or assurance that the cleaning agents used to clean and sanitize equipment is appropriate to inactivate, decontaminate and/or remove the potent/hazardous drug substances from the equipment. Furthermore, the use of (b) (4) is not as effective as using (b) (4) to achieve adequate disinfection. In addition, the manufacturer of the (b) (4) recommends that it is used as a solvent for gums, shellac and essential …
Contains “cleaning agent*”Read the Form 483 →
Bioiberica, S.A.UInspection ended Feb 4, 2022 · FEI 1000418405 · Observation 1
Cleaning procedures for equipment used in the campaign manufacture facilitated adequate cleaning and contamination prevention measures. Specifically, current cleaning operations at your firm [illegible] equipment (b)(4) with water and (b)(4) with dry clean equipment is used for campaign production on successive [illegible] adequately validated to be cleaned at appropriate intervals to prevent build-up [illegible] degradants or objectionable …
Contains “cleaning procedure*”Read the Form 483 →
Vita Pharmacy, LLC dba Talon Pharmacy of BoerneInspection ended Nov 2, 2021 · FEI 3015826784 · Observation 3
OBSERVATION #3 On 10/27/2021, I observed a dark residue on the plastic grille enclosing the HEPA filter located in the ISO 5 workbench area.
Contains “residue*”Read the Form 483 →
Dr. Reddy's Laboratories Ltd.Inspection ended Oct 29, 2021 · FEI 3006549835 · Observation 8
… The effectiveness of your cleaning process and microbes that could negatively impact your aseptically filled product.
Contains “cleaning process*”Read the Form 483 →
Pharmcore Inc. dba Hallandale PharmacyInspection ended Sep 24, 2021 · FEI 3014480778 · Observation 1
Cleaning procedures are inadequate to prevent cross contamination. Specifically, Your firm cleans and disinfects the sterile compounding suites for hazardous and non-hazardous drug products [illegible] basis prior to aseptic activities. Your current procedure is to clean the sterile hazardous suite first before cleaning the sterile non-hazardous suite. The order in which you clean is inappropriate because it may potentially cross contaminate and …
Contains “cleaning procedure*”Read the Form 483 →
People's Custom Rx and Clinical Care, LLCInspection ended Aug 5, 2021 · FEI 3003780900 · Observation 3
Non-microbial contamination was observed in your non-sterile drug production area. Specifically, on 07/13/2021, we observed what appeared to be drug product residue on two ceiling light fixtures in the firm's non-sterile compounding area. These light fixtures were directly above the firm's non-sterile benchtop drug product staging areas. The firm was continuously processing non-sterile drug products in this area during this inspection. On …
Contains “residue*”Read the Form 483 →
Med Shop Total Care Inc.Inspection ended Jul 27, 2021 · FEI 3002835459 · Observation 3
Non-microbial contamination was observed in your production area. Specifically, the metal screen in front of the HEPA filter for hood, identified as (b)(4), has brownish residue on the lower left portion.
Contains “residue*”Read the Form 483 →
Fujifilm Diosynth Biotechnologies USAInspection ended Apr 21, 2021 · FEI 3000718852 · Observation 4
… No swab samples were taken to demonstrate adequate cleaning. b. FDBU-SOP-0388: Changeover of Processing Equipment and Manufacturing Areas, version 32, effective date: 08 Nov. 2019 and FDBU-SOP-0462: Cleaning Program for Process Equipment, Revision 09, Effective Date: 02 Apr 2020 allow equipment recleaning if a swab sample result failed to meet the acceptance criteria without conducting a root cause investigation. An investigation is only required …
Contains “swab*”Read the Form 483 →
Emergent Manufacturing Operations Baltimore, LLC.Inspection ended Apr 20, 2021 · FEI 3015448605 · Observation 2
… The manufacturing rooms and corridors are not cleaned with a (b) (4). c. The painted floors in the warehouse were observed to be peeling on multiple days during the inspection. Large areas of the painted surface are missing in front of the (b) (4) and (b) (4) sampling rooms. The damaged floors and rough surfaces do not allow for adequate cleaning and sanitization. d. On 4/14/2021, the paint on the walls of the controlled not classified corridors …
Contains “not cleaned”Read the Form 483 →
Emergent Manufacturing Operations Baltimore, LLC.Inspection ended Apr 20, 2021 · FEI 3015448605 · Observation 9
Equipment and/or utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug substance. Specifically, a. The non-dedicated (b) (4) (b) (4) used to hold (b) (4) raw materials are not required by written procedure to be cleaned after each use. The procedure as described in SOP001518 (version 14) requires that they are (b) (4) (b) (4) with …
Contains “not cleaned”Read the Form 483 →
Imprimis NJOF, -LLCInspection ended Jan 29, 2021 · FEI 3013024146 · Observation 1
… As part of the investigation you verified cleaning records for the filling line, differential pressure of the room throughout the run, environmental monitoring results (air monitoring, personnel monitoring, and surface sampling), and finish product sterility testing. Since the test results reviewed in your investigation were within specification the batch was released on July 07, 2020 with a BUD of April 30, 2021. However, the investigation did …
Contains “cleaning record*”Read the Form 483 →
Imprimis NJOF, -LLCInspection ended Jan 29, 2021 · FEI 3013024146 · Observation 6
… During inspectional walkthrough on 10/06/2020, return air duct in Room #(b) (4) (ISO 7) was found visibly dirty with unknown residue. The firm was on active shut down from (b) (4), where facility cleaning and certification took place. In addition, there is no established frequency for preventative maintenance and no records are available for cleaning of air ducts on periodic basis. The firm's Preventative Maintenance Program for facilities and …
Contains “residue*”Read the Form 483 →
Millers of Wyckoff, IncInspection ended Oct 9, 2020 · FEI 3004600183 · Observation 1
… Utensils used in the production of these potent drugs, such as spatulas, jars and glass beakers, are not dedicated and not cleaned with a process that utilizes an agent to deactivate residual APIs. Your firm utilizes a store-bought brand liquid dish detergent and potable water for cleaning of utensils in the processing of potent APIs. The following potent drug products were prepared and produced using the non-sterile hazardous production room on …
Contains “not cleaned”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.67Equipment cleaning and maintenanceIn this theme's rule31
- 21 CFR 211.113Control of microbiological contamination10
- 21 CFR 211.42Design and construction features6
- 21 CFR 211.22Responsibilities of quality control unit3
- 21 CFR 211.100Written procedures; deviations2
- 21 CFR 211.192Production record review2
- 21 CFR 211.28Personnel responsibilities1
- 21 CFR 211.56Sanitation1
- 21 CFR 211.58Maintenance1
- 21 CFR 211.94Drug product containers and closures1
Ask FDAgent about equipment cleaning in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.