Skip to content

Zhejiang Tianyu Pharmaceutical Co Ltd

Jiangkou Development Zone, Huangyan, Taizhoushi, China

FEI 3010972581DUNS 528277531

FDA has 4 inspections on file for Zhejiang Tianyu Pharmaceutical Co Ltd in Taizhoushi, China (FEI 3010972581), from 2015 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. One of the three FOIA requests for this site has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Mar 4, 2022. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant is Zhejiang Tianyu Pharmaceutical Co., Ltd. (D-U-N-S 528277531).

Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
4, 2015–2024
2 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
1 of 4
Form 483s posted by FDA
↗
Requested under FOIA
3 requests, latest Apr 16, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Failure to extend investigations

      OBSERVATION 1 (Quality System) Your firm failed to extend investigations to other batches that may have been associated with a specific failure or deviation, Specifically, On July 2020, your firm received a notification from one of your customers, requesting your firm to evaluate the possibility your process may produc(' •H•J In your firm's investigation, it was identified that [illegible] impurity is present in API in amounts higher than the specification established by your firm of [illegible] ppm. Your firm confirmed that at least three (3) batches of API were over [illegible] ppm. Those batches were potentially used and distributed in finished dosage forms for the US market. In addition, your firm established in our investigation that the manufacturing process of the API previous to August 2018 had higher risk of producing '[illegible]' as a by-product of your manufacturing process, however, your firm did not extend the investigation to those batches. Approximately [illegible] batches manufactured on 2018 were sold for potential introduction in the US market.

    2. Observation 2

      Insufficient impurity evaluation

      OBSERVATION 2 (Quality System) There is a failure to thoroughly review any unexplained discrepancy or any of its components to meet any of its specifications shall be thoroughly investigated, whether or not the batch has been already distributed. Specifically, [illegible] for control of impurity evaluation during API process development establishes that impurity evaluation should be conducted before or after synthesis route is selected or confirmed. The procedure establishes that reagents, synthesis, reactions and by-products of starting material, intermediate, final product are to be evaluated for [illegible] impurity. a) Your firm did not evaluate the possibility of }H• impurity !tiH•i ,__...and !tiH•i into n4!~ !DHJ tDH•J r !tiH•J !. API which are a by-products of the ___.n of the ___ , ____. The failure of your firm to conduct a thorough evaluation resulted in complaints from your customers that some batches did not meet the specification /bH•J ~fH•r---i b) Your firm failed to identify [illegible] as potential impurity of your process. After your firm was notify about the impurity, the testing of your batches confirm the presence of [illegible] in amounts of to H•i ppm (specification to H•i ppm). This resulted in returns of over thirty (30) batches of API distributed for usage in finished dosage forms for the US market. From the returned batches, eleven (11) were not returned entirely and appear to be used by your customers. c) The initial risk assessment of !tiH•i approved on 09/23/2020 was not assessed for the potential carryover of impurities from the starting materials, !fH•i Your firm has received at [illegible] least one (1) complaint for the presence of [illegible] between [illegible] (manufacturing start date) and November 2021 (complaint date).

    Show observation 3
    1. Observation 3

      Inadequate equipment cleaning/maintenance

      OBSERVATION 3 (Facilities and Equipment System) Equipment and utensils are not cleaned or maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, There is no assurance that your firm's production equipment is properly maintained in order to prevent it from becoming a potential source of contamination for the manufactured products from this equipment, for example; a) Your firm failed to complete the cleaning validation studies previous to release and deliver [illegible] batches of (D)(4) starting material to [illegible]. b) According to SOP-49520-208, "Cleaning SOP" a deep clean should occur [illegible]. A review of your usage logbook identifies cleaning occurred on the following dates, outside of the specified time-frame: [illegible] identified as located in the Workshop II used for the synthesis of [illegible] were observed with an apparent brownish rust like (rouge) spots on the top walls of the [illegible] on product contact surface areas. In addition, layers of thick black spots are above the brownish rust like (rouge) spots around the walls of the [illegible] on product contact surface areas. d) SOP# SMP-EN-003: titled "Equipment Maintenance Procedure"; V02; failed to include the [illegible] (Example: using a [illegible] of the ___ when rust (rouge) is identified during routine equipment maintenance).

  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Apr 16, 2025. Each one asked for a Form 483.

  • Inspection ending Nov 29, 2024VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Mar 13, 2025FDA-FOIA-2025-2348Form 483· 1 of 3 sitesClosed
  • Inspection date not given

    2 requests. FDA released records in answer to a request for its Form 483 on Jul 9, 2025. FDAgent holds no copy that FDA posted.

    1. Apr 16, 2025FDA-FOIA-2025-3507Form 483· 1 of 6 sitesRecords released
    2. Jan 2, 2025FDA-FOIA-2025-56Form 483 + EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2027
Registrant
Zhejiang Tianyu Pharmaceutical Co., Ltd.D-U-N-S 528277531

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010972581 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010972581. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.