Skip to content

Zhejiang Tianyu Pharmaceutical Co. Ltd. Form 483, March 2022

FDA issued this Form 483 to Zhejiang Tianyu Pharmaceutical Co. Ltd. in Taizhoushi, China (FEI 3010972581) at the end of a drug inspection that ended March 4, 2022. It lists 3 observations. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on August 17, 2022.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 14, 2025. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Mar 4, 2022
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 14, 2025
1,047 days after the inspection
Facility
FEI 3010972581
Taizhoushi, China

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Failure to extend investigations

    OBSERVATION 1 (Quality System) Your firm failed to extend investigations to other batches that may have been associated with a specific failure or deviation, Specifically, On July 2020, your firm received a notification from one of your customers, requesting your firm to evaluate the possibility your process may produc(' •H•J In your firm's investigation, it was identified that [illegible] impurity is present in API in amounts higher than the specification established by your firm of [illegible] ppm. Your firm confirmed that at least three (3) batches of API were over [illegible] ppm. Those batches were potentially used and distributed in finished dosage forms for the US market. In addition, your firm established in our investigation that the manufacturing process of the API previous to August 2018 had higher risk of producing '[illegible]' as a by-product of your manufacturing process, however, your firm did not extend the investigation to those batches. Approximately [illegible] batches manufactured on 2018 were sold for potential introduction in the US market.

  2. 2

    Insufficient impurity evaluation

    OBSERVATION 2 (Quality System) There is a failure to thoroughly review any unexplained discrepancy or any of its components to meet any of its specifications shall be thoroughly investigated, whether or not the batch has been already distributed. Specifically, [illegible] for control of impurity evaluation during API process development establishes that impurity evaluation should be conducted before or after synthesis route is selected or confirmed. The procedure establishes that reagents, synthesis, reactions and by-products of starting material, intermediate, final product are to be evaluated for [illegible] impurity. a) Your firm did not evaluate the possibility of }H• impurity !tiH•i ,__...and !tiH•i into n4!~ !DHJ tDH•J r !tiH•J !. API which are a by-products of the ___.n of the ___ , ____. The failure of your firm to conduct a thorough evaluation resulted in complaints from your customers that some batches did not meet the specification /bH•J ~fH•r---i b) Your firm failed to identify [illegible] as potential impurity of your process. After your firm was notify about the impurity, the testing of your batches confirm the presence of [illegible] in amounts of to H•i ppm (specification to H•i ppm). This resulted in returns of over thirty (30) batches of API distributed for usage in finished dosage forms for the US market. From the returned batches, eleven (11) were not returned entirely and appear to be used by your customers. c) The initial risk assessment of !tiH•i approved on 09/23/2020 was not assessed for the potential carryover of impurities from the starting materials, !fH•i Your firm has received at [illegible] least one (1) complaint for the presence of [illegible] between [illegible] (manufacturing start date) and November 2021 (complaint date).

  3. 3

    Inadequate equipment cleaning/maintenance

    OBSERVATION 3 (Facilities and Equipment System) Equipment and utensils are not cleaned or maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, There is no assurance that your firm's production equipment is properly maintained in order to prevent it from becoming a potential source of contamination for the manufactured products from this equipment, for example; a) Your firm failed to complete the cleaning validation studies previous to release and deliver [illegible] batches of (D)(4) starting material to [illegible]. b) According to SOP-49520-208, "Cleaning SOP" a deep clean should occur [illegible]. A review of your usage logbook identifies cleaning occurred on the following dates, outside of the specified time-frame: [illegible] identified as located in the Workshop II used for the synthesis of [illegible] were observed with an apparent brownish rust like (rouge) spots on the top walls of the [illegible] on product contact surface areas. In addition, layers of thick black spots are above the brownish rust like (rouge) spots around the walls of the [illegible] on product contact surface areas. d) SOP# SMP-EN-003: titled "Equipment Maintenance Procedure"; V02; failed to include the [illegible] (Example: using a [illegible] of the ___ when rust (rouge) is identified during routine equipment maintenance).

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.