Equipment cleaning and cleaning validation in FDA Form 483 observations
Cleaning procedures for manufacturing equipment, the studies that show they work, and the residues, swabs and logs that prove each cleaning. FDAgent finds 197 such observations in 144 Form 483s issued to 138 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 197
- Each quoted below
- Form 483s
- 144
- Posted by FDA
- Facilities
- 138
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 63 in 2026
| Year | Observations |
|---|---|
| 2008 | 1 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 0 |
| 2013 | 0 |
| 2014 | 1 |
| 2015 | 1 |
| 2016 | 10 |
| 2017 | 15 |
| 2018 | 20 |
| 2019 | 5 |
| 2020 | 5 |
| 2021 | 10 |
| 2022 | 7 |
| 2023 | 22 |
| 2024 | 13 |
| 2025 | 24 |
| 2026 | 63 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
The same entries the equipment cleaning topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“cleaning validat*” · “validat* … cleaning” · “cleaning procedure*” · “cleaning process*” · “cleaning record*” · “cleaning log*” · “cleaning agent*” · “cleaning verification” · “cleaning stud*” · “cleaning method*” · “cleaning effectiveness” · “not cleaned” · “not adequately cleaned” · “not properly cleaned” · “residue*” · “swab*” · “carry over” · “carryover”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 197 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Strive Pharmacy LLCInspection ended Sep 28, 2026 · FEI 3021042485 · Observation 4
… Red spatula with unknown white residue and powder, black spatula with unknown white residue and powder, (b)(4) with unknown white residue and a brownish particulate, scraper with unknown white residue and powder. All these items were observed to be comingled with other utensils and were designated clean and ready for use. C. The mouse, keyboard, (b)(4) scanner, and (b)(4) at the workstation for each of the (b)(4) (b)(4) in the hazardous …
Contains “residue*”Read the Form 483 →
Victory Medical Center PharmacyInspection ended Sep 10, 2026 · FEI 3010485868 · Observation 2
… These surface irregularities cannot be adequately cleaned or disinfected and provide sites where microbial contamination, cleaning solution residue, and particulate matter can accumulate and persist despite cleaning efforts. Rough and porous surface texture - The caulking surface was visibly rough and non-smooth in texture. A porous, rough surface within an ISO 5 critical zone is inherently incompatible with the cleanliness requirements of a …
Contains “residue*”Read the Form 483 →
STAQ Pharma IncInspection ended Sep 8, 2026 · FEI 3015144909 · Observation 3
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, (b)(4) located in ISO-7 Production Room (Room (b)(4)) and ISO-7 Production Room (Room (b)(4)) exhibited visible discoloration, appearing brownish to blackish in color, on (b)(4). In Room (b)(4), (b)(4) is utilized to hold a …
Opens with FDA's citation wording for 21 CFR 211.67(a)Read the Form 483 →
RC Outsourcing LLCInspection ended Sep 3, 2026 · FEI 3011967886 · Observation 4
There is a lack of written procedures assigning responsibility, providing cleaning schedules and describing in sufficient detail the methods, equipment and materials to be used for sanitation. Specifically, A. Your firm's cleaning procedure is inadequate. i. Your firm stated that only the ISO 5 laminar flow hood receives cleaning (b)(4). However, your firm failed to clean the ISO 7 classified area (b)(4) leaving cleaning to the end of production …
Contains “cleaning procedure*”Read the Form 483 →
OPS International Inc dba Olympia PharmaceuticalsInspection ended Sep 3, 2026 · FEI 3009724085 · Observation 2
… The supporting microbiological evaluation consisted of swabbing part surfaces and incubating samples in (b)(4) medium at (b)(4) for (b)(4). (1) Your firm has not provided adequate scientific justification that these incubation conditions are suitable for recovering and detecting microorganisms that may be encountered if the sterile barrier is compromised during storage within the non-classified area. (2) The provided record associated with the …
Contains “swab*”Read the Form 483 →
Houston Rx LLCInspection ended Aug 28, 2026 · FEI 3045022201 · Observation 11
Use of cleaning and disinfecting agents that may leave residues or not adequately rinsing such agents from containers, closures, or equipment that come into direct contact with drug products. Specifically, your firm uses (b)(4) and tap water to wash equipment used to make sterile drug products, including glass beakers, stir bars, and graduated cylinders. Your firm rinses the equipment with (b)(4) sterile water and then wipes the beakers and stir …
Contains “residue*”Read the Form 483 →
Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 6
… Plastic containers, lead, metal and residue from these items was observed in this recycle room. Dead roach(es), dust and debris was also observed in this recycle room. - The firm lacks controls to prevent cross contamination of lead, lead particles, and other debris from the recycle room through the rest of the facility. A door connects the warehouse / material receiving and shipping room directly to the non-sterile compounding processing and …
Contains “residue*”Read the Form 483 →
Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 7
… There is no method for detecting and controlling cross contamination such as swabbing and analytical lab testing for particles, lead particles, and other chemicals.
Contains “swab*”Read the Form 483 →
Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 8
… A (b)(4) alone will not efficiently lift or release microorganism from a (b)(4) surface on to an (b)(4) plate compared to a pre-saturated swab. This method also does not include the use of neutralizing buffer which is necessary to neutralize residual disinfectants. This calls into question the validity of your test results.
Contains “swab*”Read the Form 483 →
Wanbury LimitedInspection ended Jul 17, 2026 · FEI 3002980818 · Observation 2
Established procedures are not followed for equipment cleaning, and cleaning records do not accurately reflect actual cleaning activities. Specifically, A) On July 13, 2026, during a facility walkthrough of the API manufacturing area, Block (b)(4) significant quantities of visible product residues of (b)(4) were observed on both the external and internal surfaces of (b)(4) Equipment following (b)(4) processing operations for Batch Nos. (b)(4). …
Contains “cleaning record*”Read the Form 483 →
Cascade Specialty Pharmacy LLCInspection ended Jul 17, 2026 · FEI 3015133983 · Observation 3
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, Your firm has not conducted an in-house efficacy study to verify the effectiveness of the deactivating agent used for beta-lactam residue on production equipment from manufacturing and handling beta-lactam drug substances, or to confirm that the contact …
Opens with FDA's citation wording for 21 CFR 211.67(b)Read the Form 483 →
Rubicon Research LimitedInspection ended Jul 3, 2026 · FEI 3016480976 · Observation 2
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, A) There is no procedure currently in effect for the cleaning of the (b)(4) used for manufacturing (b)(4) Tablets (b)(4) mg strengths. 122 (b)(4) B) There is no cleaning record which documents the step-by-step cleaning activities required …
Opens with FDA's citation wording for 21 CFR 211.67(b)Read the Form 483 →
Glenmark Pharmaceuticals LimitedInspection ended Jun 30, 2026 · FEI 3004672766 · Observation 1
Equipment and utensils are not cleaned or sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, A. Inadequate Cleaning Procedures-Insufficient Time Allocation Your firm's written cleaning procedure, SOP CM/PD002 "Cleaning and Sanitization of Production Areas, Other than Production Areas, Wash Areas and Drain Points", establishes …
Contains “not cleaned”Read the Form 483 →
Eugia Steriles Private LimitedInspection ended Jun 19, 2026 · FEI 3027357163 · Observation 1
… However, there is no detailed cleaning procedure ensuring that each of the (b)(4) in the sample vial tray are adequately sanitized prior to reentry in the Grade A filling line. 2. On June 16, 2026 at approximately 14:25:06 the operator removed his gloved hands from the filling line (b)(4) after unloading (b)(4) stoppers and made direct contact with the Grade B environment. However, he did not sanitize his gloved hands prior to re-entering his …
Contains “cleaning procedure*”Read the Form 483 →
Cytovance Biologics Inc.Inspection ended Jun 17, 2026 · FEI 3006341547 · Observation 1
… I observed the appearance of rust and residue in the dirty return air vents in the Inoculum Preparation Room (b) (4) (ISO 7) and Solvent Preparation Room (b) (4) (ISO 8). Cell thaw activities are performed in Room (b) (4). Room (b) (4) is dedicated to the preparation of media and buffer solutions for all products other than (b) (4). B. I observed the appearance of moisture ingress on the drywall adjacent to the return air vent located to the left …
Contains “residue*”Read the Form 483 →
Cytovance Biologics Inc.Inspection ended Jun 17, 2026 · FEI 3006341547 · Observation 3
Failure to establish appropriate cleaning procedures for all manufacturing equipment. Specifically, your firm failed to adequately validate the cleaning method for the (b) (4) (Working Copy No.: WC-18-0287) used in the manufacture of (b) (4). Your cleaning validation did not include a risk assessment to identify worst-case cleaning locations, nor did it specify sampling locations or provide a scientific rationale for their selection. Your firm …
Contains “cleaning procedure*”Read the Form 483 →
XeCare LLCInspection ended Jun 17, 2026 · FEI 3017865039 · Observation 1
OBSERVATION 1 Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, 1) Your firm routinely produces hazardous drug products on shared tablet press equipment without employing a deactivating agent as part of the cleaning process between batches, relying solely on (b) (4). From 6/3/2026 through 6/9/2026, your firm …
Contains “cleaning process*”Read the Form 483 →
Fayetteville VA Medical CenterInspection ended Jun 15, 2026 · FEI 1073803 · Observation 2
… The technician was instructed to clean the (b)(4) and brown residue was observed on the wipe. The aforementioned (b)(4) is utilized in the production of several sterile products including: Piperacillin/Tazobactam 2.25gm/vial; Doxycycline Hyclate 100mg/vial; Ampicillin/Sulbactam 1.5gm/vial; Vancomycin HCL 1gm/vial and Infliximab 100mg/vial.
Contains “residue*”Read the Form 483 →
Fayetteville VA Medical CenterInspection ended Jun 15, 2026 · FEI 1073803 · Observation 3
… The firm’s current unofficial cleaning procedure allows operators to only apply (b)(4) to the (b)(4) following the production of any Beta-Lactam products.
Contains “cleaning procedure*”Read the Form 483 →
Lyophilization Services of New England, Inc. dba PCI Pharma ServicesInspection ended Jun 10, 2026 · FEI 3008546445 · Observation 1
… The (b)(4) fill line (b)(4) process asset J0007 includes a fixed recipe for CIP, with the CIP process validated based on (b)(4) TOC swab testing. Although the cleaning process is validated, the recipe does not control to a final rinse conductivity value that would provide a robust cleaning process to account for variability in the batch manufacturing process. j. According to Document: POL-05158, (b)(4) and (b)(4) Rev 02, Effective date 14 …
Contains “swab*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.67Equipment cleaning and maintenanceIn this theme's rule31
- 21 CFR 211.113Control of microbiological contamination10
- 21 CFR 211.42Design and construction features6
- 21 CFR 211.22Responsibilities of quality control unit3
- 21 CFR 211.100Written procedures; deviations2
- 21 CFR 211.192Production record review2
- 21 CFR 211.28Personnel responsibilities1
- 21 CFR 211.56Sanitation1
- 21 CFR 211.58Maintenance1
- 21 CFR 211.94Drug product containers and closures1
Ask FDAgent about equipment cleaning in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.