Cytovance Biologics Inc. Form 483, June 2026
FDA issued this Form 483 to Cytovance Biologics Inc. in Oklahoma City, Oklahoma (FEI 3006341547) at the end of a drug inspection that ended June 17, 2026. It lists 7 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 17, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jun 17, 2026
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 17, 2026
- 153 days after the inspection
The 7 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Facility maintenance rust moisture insects
Failure to properly maintain buildings, facilities and equipment used in the manufacture of active pharmaceutical ingredients (API). Specifically, On June 12, 2026, the following deficiencies were identified in manufacturing areas located in Building (b) (4) where manufacturing of bulk drug substances occurs, including (b) (4). These observations are illustrative and not exhaustive. A. I observed the appearance of rust and residue in the dirty return air vents in the Inoculum Preparation Room (b) (4) (ISO 7) and Solvent Preparation Room (b) (4) (ISO 8). Cell thaw activities are performed in Room (b) (4). Room (b) (4) is dedicated to the preparation of media and buffer solutions for all products other than (b) (4). B. I observed the appearance of moisture ingress on the drywall adjacent to the return air vent located to the left of your Biosafety Cabinet (b) (4) in Room (b) (4) (ISO 7). This room is used for inoculum preparation of (b) (4). Additionally, the appearance of moisture ingress was also observed on the (b) (4) flooring used as baseboard material in the same area. Moisture infiltration of this nature may compromise the structural integrity of the room and present a risk of microbial contamination in a critical manufacturing environment. C. I observed live insects in Solvent Preparation Room (b) (4) (ISO 8). This is a REPEAT OBSERVATION from the inspection conducted 07/11-20/2017.
- 2
Inadequate equipment qualification smoke sterilizer
Equipment used in the manufacture of active pharmaceutical ingredients is not fully qualified. Specifically, A. Smoke studies performed during the performance qualification of the ISO 5 biological safety cabinets (BSC) and laminar flow hoods (LFH) in Building (b) (4) are inadequate to evaluate unidirectional airflow and contamination risk. To manufacture the drug substance (b) (4), your firm uses the following equipment for cell thaw ((b) (4); Room (b) (4)), (b) (4) inoculation ((b) (4); Room (b) (4)), and bulk fill ((b) (4); Room (b) (4)). i. Absence of Study Protocols: Your firm failed to establish and approve protocols for the smoke studies conducted by your third-party vendor. For example, there is no documentation detailing the type of fogger or the fluid used to generate the smoke. Without this information, your firm cannot verify that the generated smoke was neutrally buoyant. The inability to confirm neutral buoyancy compromises the validity of the study, as it may mask true airflow patterns and preclude the identification of critical vulnerabilities such as recirculating air or dead zones. ii. Inadequate Visualization: The angle of video recording during dynamic conditions of (b) (4), and (b) (4) does not capture the full range of airflow, preventing a complete evaluation of air sweeps over the critical areas. iii. Insufficient Simulations: Your firm failed to evaluate dynamic conditions that accurately represent the drug substance commercial process for (b) (4). Routine activities, including the cell thaw of (b) (4) in (b) (4) (Room (b) (4)) and (b) (4) inoculation in (b) (4) (Room (b) (4)), were excluded from the studies. Additionally, your Quality Unit selected a worst-case dynamic condition (the (b) (4) process of a (b) (4) to collect samples inside (b) (4) and (b) (4)) that is not established in your commercial process and failed to provide a risk assessment or scientific rationale to justify this selection. This is a REPEAT OBSERVATION from the inspection conducted 05/01-9/2019. B. Your firm's (b) (4) validation (b) (4) for the (b) (4) Sterilizer, Equipment ID: (b) (4), located in Building (b) (4) is inadequate, in that: Your Quality Unit failed to adequately justify and document the placement of biological indicators (BIs) during the sterilization qualification of the (b) (4) used in the manufacture of (b) (4). First, no risk assessment was conducted to identify the worst-case, hardest-to-sterilize locations within the (b) (4), including the (b) (4) of the (b) (4). Second, performance qualification records (Working Copy No.: WC-25-0037, including the photographic record in Attachment 11.5.2) fail to specify the exact locations where BIs were placed. Critical manufacturing components used in production (b) (4) lot (b) (4) (via (b) (4) Batch Medium Lot (b) (4)) and lot (b) (4) (via (b) (4) Batch Medium Lot (b) (4)) were sterilized using an inadequately validated (b) (4).
- 3
Inadequate cleaning validation procedures
Failure to establish appropriate cleaning procedures for all manufacturing equipment. Specifically, your firm failed to adequately validate the cleaning method for the (b) (4) (Working Copy No.: WC-18-0287) used in the manufacture of (b) (4). Your cleaning validation did not include a risk assessment to identify worst-case cleaning locations, nor did it specify sampling locations or provide a scientific rationale for their selection. Your firm uses the (b) (4).
- 4
Inadequate deviation investigation water contamination
Failure to adequately investigate deviations and implement appropriate corrective actions. Specifically, your firm has not conducted a thorough investigation to find and remediate the source/root cause of the microbiological contamination in the (b) (4) system in Building (b) (4). DEV-2026-0012 initiated April 23, 2026, noted a trend in Total Aerobic Microbial Count (TAMC) testing of several (b) (4) drops located in Building (b) (4). Organisms recovered include Burkholderia cepacia and Ralstonia insidiosa. Your investigation determined that the elevated levels of TAMC counts "were caused by microbial contamination/biofilm within the distribution loop". Final approval by QA and closure of the deviation was on May 13, 2026 with no corrective action identified. These same two organisms have been recovered from the (b) (4) system in Building (b) (4) in July 2025 (DEV-2025-0037). (b) (4) is used to feed the (b) (4) system in Building (b) (4) that in turn is used to manufacture buffers for several products including (b) (4), as well as to make cleaning solutions for use in cleaning/sanitizing the facility to include floors, walls, ceilings, benches, tables and chairs.
- 5
Unjustified periodic raw material testing intervals
There is a failure to justify defined intervals for conducting periodic full testing (verifying supplier's Certificate of Analysis). Specifically, per OKC-SOP-1379 Raw Material Test Strategy, revision 03 effective 18 Feb 2026, periodic full testing of raw materials is performed (b) (4) (or the next receipt (b) (4) after the last full testing) for common stock products and at every (b) (4) receipt for project specific raw materials. Your firm does not have documented justification/rationale for the frequency of performing full testing of raw materials. For example, for (b) (4) and (b) (4) are considered excipients in the final drug substance. The last full testing for (b) (4) was performed on receiving lot #(b) (4) received 02/20/2023. Since the last time full testing was performed, your firm has received in (b) (4) project specific lots of this raw material. (b) (4) is considered a common stock and a project specific product depending on how the purchase order is coded. The product can be used in several products as common stock, including as an excipient in the (b) (4). The last full testing was performed on lot #(b) (4) received on 12/09/2022. Since the last full testing, your firm has received in (b) (4) lots of common stock and (b) (4) lots of project specific (Project (b) (4)) lots.
- 6
Non-representative raw material sampling
Failure to obtain a representative sample of each batch of each raw material for release testing. Specifically, your firm has no documented rationale/justification for sampling only (b) (4) of a raw material regardless of the number of containers received. For example, (b) (4) containers were included in receiving #(b) (4) (vendor lot #(b) (4)) of (b) (4). Only (b) (4) sampled for identity testing. This lot has been used to manufacture several lots of (b) (4), including lot #(b) (4) released on March 19, 2026.
- 7
Missing labeling procedures and records
Failure to have written procedures for the printing, issuance, review/approval and reconciliation of all labeling applied to bulk drug substances and failure to maintain a representative copy of all labeling used. Specifically, your firm at times will collect a "(b) (4) sample" that is to be sent with the finished product to your customer, including for (b) (4). Your firm has no written procedures for the printing, review and approval of the label that is placed on the container containing the (b) (4) sample nor do you maintain a copy of the actual label placed on the container. The label(s) are printed by Manufacturing and are not reviewed and approved by QA/QC prior to labeling operations.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.