Fayetteville VA Medical Center Form 483, June 2026
FDA issued this Form 483 to Fayetteville VA Medical Center in North Carolina (FEI 1073803) at the end of an inspection that ended June 15, 2026. It lists 3 observations.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Sep 3, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jun 15, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Sep 3, 2026
- 80 days after the inspection
The 3 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Microbial contamination in ISO Class 5
Microbial contamination was present in the [illegible]. Specifically. On 05/08/2025, a surface sample collected from (b)(4) (S/N: (b)(4)), an ISO Class 5 (b)(4) used for the production of sterile drug products, yielded 4 cfu/plate, exceeding the action limit of [illegible] cfu/plate. The sample was classified as Out of Compliance (OOC) and the following organisms were identified: Cladosporium spp. (pathogenic), Corynebacterium tuberculostearicum, Staphylococcus saprophyticus, and Fungal Overgrowth. Per email documentation provided by the firm, the (b)(4) (S/N (b)(4)) was not used following the OOC result until passing recertification, which occurred approximately (b)(4) later. Your firm failed to investigate the cause of the OOC result and implement a corrective action plan as required by your Policy Number 797-2022, entitled, Microbiological Air and Surface Monitoring Program, version 2. Additionally, your firm was unable to demonstrate that the (b)(4) was not used for the production of sterile drug products during this period.
- 2
Inadequate cleaning of ISO-5 equipment
Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area. Specifically, Areas of reddish-brown and opaque discoloration/staining were observed on the ceiling [illegible] cover within the ISO-5 (b)(4) S/N: (b)(4). On 06/08/2026, we observed a technician conduct cleaning and disinfection of the ISO-5 (b)(4) S/N: (b)(4). We observed that the technician failed to clean the recessed area of a (b)(4) on the side of the (b)(4). The technician was instructed to clean the (b)(4) and brown residue was observed on the wipe. The aforementioned (b)(4) is utilized in the production of several sterile products including: Piperacillin/Tazobactam 2.25gm/vial; Doxycycline Hyclate 100mg/vial; Ampicillin/Sulbactam 1.5gm/vial; Vancomycin HCL 1gm/vial and Infliximab 100mg/vial.
- 3
Inadequate segregation for beta-lactams
Beta-lactam drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, The firm has routinely produced both Beta-lactam and non-Beta-lactam products within the same ISO-5 (b)(4) (S/N: (b)(4)) and (b)(4) (S/N: (b)(4)). During this time the firm has failed to conduct decontamination of the (b)(4) to prevent potential cross-contamination. The firm's procedure, Cleaning and Disinfecting Compounding Areas, only require the operator to apply sterile (b)(4) to surfaces (b)(4) production. For example, the firm produced Piperacillin/Tazobactam 4.5g/Vial Injection; Sodium Chloride 0.9% Injection Bag 100ml on 05/28/2026. The firm failed to conduct decontamination of the (b)(4) then produced Phosphorus 3mmol/Potassium 4.4 Meq/ml Injection; Sodium Chloride 0.9% Injection Bag 250ml. On 06/09/2026, we observed production within ISO-5 (b)(4) (S/N: (b)(4)). We then observed that the technician only applied (b)(4) to the (b)(4) of the (b)(4) and to no other surfaces. The firm’s current unofficial cleaning procedure allows operators to only apply (b)(4) to the (b)(4) following the production of any Beta-Lactam products.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.