Strive Pharmacy LLC
Arizona
FEI 3021042485
FDA has one inspection on file for Strive Pharmacy LLC in Arizona (FEI 3021042485). It ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 10 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 1, in 2026
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetPosted 483 · 10 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Microbial contamination in ISO 5 areas uninvestigated
Microbial contamination was present in the ISO 5 area and areas adjacent to production areas. Specifically, Periodic Air and Surface Environmental Monitoring A. There was an action level (b)(4) active air sample in ISO 5 LFH (Hood) on 11/26/25. Sample ID #BHT112625NHDH1, result = 15 cfu, action limit for ISO 5 air samples is [illegible] cfu. Microorganisms were identified as Micrococcus species and coag-negative Staphylococcus species. There was no additional investigation or corrective actions. Technicians do not document what specific activity was occurring in the LHF during sample collection. Technicians made about (b)(4) sterile drug lots inside LFH on 11/26/25. Examples of batches produced and dispensed include Semaglutide 2.5 mg/mL, 2 mL solution for injection, batches LG364186933 and LG364186939. Post-Batch (b)(4) and Surface Sampling B. About post-batch (b)(4) and surface samples collected inside ISO 5 LFH or ISO 5 BSC during the previous year had at least 1 cfu after incubation. Additional disinfection and investigation were not always completed for below action level results, including recovery of mold and spore forming microorganisms. Most batches associated with these below the action level results were released. Examples of batches associated with below action level ISO 5 growth include: Semaglutide/Glycine/B12 injection, 5/5/1 mg/mL, 0.5 mL, batch LG364285563, expiration 10/25/26, post-batch (b)(4) sample ID #DJO072726, result = 1 CFU Alternaria species. The batch Production Record Checklist inaccurately lists the (b)(4) result as <1 CFU, and personnel did not complete the required evaluation for (b)(4) growth. The entire lot was dispensed to fill more than prescriptions. Semaglutide/Glycine/B12 5/5/1 mg/mL, 2 mL, batch LG364281132, sample ID #GD071926LH, result = 3 cfu Bacillus species, coagulase-negative Staphylococcus species, and Micrococcus species. This lot was dispensed. Tirzepatide/Glycine/B12 10mg/5mg/500mcg/mL injection, 4 mL, batch LG364238721, sample ID #OYM032526LH, result = 1 cfu Bacillus species. This lot was dispensed.
- Observation 2
Rapid personnel movements disrupting unidirectional airflow
Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow. Specifically, sterile production technicians did not always use slow and deliberate movements in the ISO 5 LHFs and ISO 7 Buffer Rooms. Technicians moved quickly during cleaning, LHF setup, and filling and stoppering of multiple sterile injectable drugs on 09/15/26.
Show observations 3 to 10
- Observation 3
Open sterile disinfectants left indefinitely in classified areas
Use of non-sterile disinfecting agents and cleaning wipes in the ISO 5 area and classified areas. Specifically, sterile (b)(4) wipes, bottles of sterile (b)(4) solution, and bottles of sterile (b)(4) remained open in the ISO 7 Buffer Rooms indefinitely while technicians actively used these items to disinfect and clean items that entered the ISO 5 LHF and ISO 7 Buffer Rooms on 09/15/26.
- Observation 4
Inadequate hazardous drug containment and cleaning
Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, A. Nonsterile production technicians in the hazardous room do not always follow the deactivate, decontaminate, and clean process. Technicians did not adequately deactivate or decontaminate mixing blades, spatulas, glass beakers, and various (b)(4) removable parts that directly contact hazardous drugs. I watched multiple technicians wipe equipment and utensils with a single-use wipe (b)(4) with (b)(4) or (b)(4), immediately rinse the items with tap water, wash the items with tap water and (b)(4), and then place them on a drying rack. B. Red spatula with unknown white residue and powder, black spatula with unknown white residue and powder, (b)(4) with unknown white residue and a brownish particulate, scraper with unknown white residue and powder. All these items were observed to be comingled with other utensils and were designated clean and ready for use. C. The mouse, keyboard, (b)(4) scanner, and (b)(4) at the workstation for each of the (b)(4) (b)(4) in the hazardous production room were not deactivated, decontaminated, and cleaned adequately. I watched a technician use the mouse at the workstation next to Hood on multiple days. The mouse contained visible white residue in the seams every time I examined it. I watched multiple technicians remove their hands from the (b)(4) during active production and then use items at the workstation without decontaminating or changing gloves. D. (b)(4) Hood had a hole and an about two-inch-long open crack on the back wall of the unit. There was also a buildup of residue on the left side panel above the hinge for the front panel. E. The work surfaces in (b)(4) Hood, Hood, Hood and Hood contained excessive scratches, pits, and other wear that made the surfaces not smooth and easily deactivated, decontaminated, and cleaned.
- Observation 5
Inadequate dynamic smoke studies for airflow
Smoke studies were inadequately performed under dynamic conditions. Specifically, smoke studies did not introduce smoke into the entire ISO 5 LFH to confirm unidirectional airflow throughout the aseptic processing area. Additional technicians in the ISO 7 Buffer Rooms during the smoke studies were stationary which was not representative of routine production. I reviewed the most recent smoke studies completed in April 2026 for Hood and Hood in Lane and completed in May 2026 for Hood and Hood in Lane. Technicians produced all sterile injectable drugs in these LFH which includes more than (b)(4) sterile drug vials in the previous three months.
- Observation 6
Difficult to clean production surfaces and sinks
Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces. Specifically, A. There was visible adhesive facing upward on the partially unsecured tape attempting to secure the damaged height adjustment control panel underneath the worksurface of ISO 5 Hood. The exposed adhesive was within six inches of the seated technician filling multiple lots of Semaglutide 2.5 mg/mL on 09/15/26. B. There is a large glassware washing sink and a small hand washing sink in the ISO 8 Anteroom. Technicians wash and dry all glassware used during sterile compounding/formulation in the ISO 8 Anteroom before it is transferred to another room for (b)(4) preparation. Sterile production technicians gown within a few feet of these sinks. The ISO 8 Anteroom is connected to both ISO 7 Prep Rooms used to formulate drugs. Both ISO 7 Prep Rooms are connected to ISO 7 Buffer Rooms that contain ISO 5 LFHs used to sterile (b)(4) and fill finished drugs. C. There was apparent corrosion and damage to the bottom of multiple (b)(4) door frames where they met the floor in the cleanroom.
- Observation 7
Improper gowning near glassware washing sink
Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated. Specifically, I watched a sterile production technician don sterile garb inside the ISO 8 Anteroom about two to four feet away from a laboratory support technician who was manually washing about 15 soiled glassware items in the approximately four-foot-wide sink. The production technician entered the Lane ISO 7 Prep Room. Flow of materials and personnel: ISO 8 anteroom → ISO 7 Prep Rooms → ISO 7 Buffer Rooms.
- Observation 8
Media fills not simulating worst-case conditions
Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions. Specifically, media fills are not always conducted under the most challenging and stressful conditions. Technicians work (b)(4) shifts, but there is no requirement for media fills to occur at the end of a technician's shift when they are presumably most fatigued. The end of the shift ensures the technician would have interacted with the most materials, personnel, environment, and other items that could contribute to particulates, microorganisms, or other contaminants in the media fill.
- Observation 9
Stools and benches excluded from environmental monitoring
Inadequate routine environmental monitoring in the classified areas. Specifically, stools positioned at all (b)(4) ISO 5 LFH are not included in the EM surface sample program. I observed technicians in the Lane ISO 7 buffer room and the Lane ISO 7 buffer room directly contact a stool with their gloved hands during filling operations for sterile injectable drugs. Technicians sit on the stools while filling. Technicians sit on a bench in the ISO 8 anteroom while donning sterile gowning. The anteroom bench is approximately than one-foot-away from the hand washing sink and four-foot-away from the glassware washing sink.
- Observation 10
Damaged personnel monitoring plates still incubated
Lack of adequate personnel sampling. Specifically, a pharmacist who was performing (b)(4) assessment on 09/16/26 cracked both (b)(4) plates all the way across and through the depth of the (b)(4). Also, an approximately 1-inch piece broke off the side of the (b)(4) plate lid and fell onto the (b)(4) surface. The QA Technician administering the assessment did not invalidate the assessment and incubated the damaged plates. Damaged (b)(4) surface can inhibit growth of microorganisms.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3021042485 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3021042485. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.