Strive Pharmacy LLC Form 483, September 2026

FDA issued this Form 483 to Strive Pharmacy LLC in Arizona (FEI 3021042485) at the end of an inspection that ended September 28, 2026. It lists 10 observations.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 13, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Sep 28, 2026
—
FDA's outcome
Not classified
Not classified yet
Posted by FDA
Nov 13, 2026
46 days after the inspection
Facility
FEI 3021042485
Arizona

The 10 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Microbial contamination in ISO 5 areas uninvestigated

    Microbial contamination was present in the ISO 5 area and areas adjacent to production areas. Specifically, Periodic Air and Surface Environmental Monitoring A. There was an action level (b)(4) active air sample in ISO 5 LFH (Hood) on 11/26/25. Sample ID #BHT112625NHDH1, result = 15 cfu, action limit for ISO 5 air samples is [illegible] cfu. Microorganisms were identified as Micrococcus species and coag-negative Staphylococcus species. There was no additional investigation or corrective actions. Technicians do not document what specific activity was occurring in the LHF during sample collection. Technicians made about (b)(4) sterile drug lots inside LFH on 11/26/25. Examples of batches produced and dispensed include Semaglutide 2.5 mg/mL, 2 mL solution for injection, batches LG364186933 and LG364186939. Post-Batch (b)(4) and Surface Sampling B. About post-batch (b)(4) and surface samples collected inside ISO 5 LFH or ISO 5 BSC during the previous year had at least 1 cfu after incubation. Additional disinfection and investigation were not always completed for below action level results, including recovery of mold and spore forming microorganisms. Most batches associated with these below the action level results were released. Examples of batches associated with below action level ISO 5 growth include: Semaglutide/Glycine/B12 injection, 5/5/1 mg/mL, 0.5 mL, batch LG364285563, expiration 10/25/26, post-batch (b)(4) sample ID #DJO072726, result = 1 CFU Alternaria species. The batch Production Record Checklist inaccurately lists the (b)(4) result as <1 CFU, and personnel did not complete the required evaluation for (b)(4) growth. The entire lot was dispensed to fill more than prescriptions. Semaglutide/Glycine/B12 5/5/1 mg/mL, 2 mL, batch LG364281132, sample ID #GD071926LH, result = 3 cfu Bacillus species, coagulase-negative Staphylococcus species, and Micrococcus species. This lot was dispensed. Tirzepatide/Glycine/B12 10mg/5mg/500mcg/mL injection, 4 mL, batch LG364238721, sample ID #OYM032526LH, result = 1 cfu Bacillus species. This lot was dispensed.

  2. 2

    Rapid personnel movements disrupting unidirectional airflow

    Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow. Specifically, sterile production technicians did not always use slow and deliberate movements in the ISO 5 LHFs and ISO 7 Buffer Rooms. Technicians moved quickly during cleaning, LHF setup, and filling and stoppering of multiple sterile injectable drugs on 09/15/26.

  3. 3

    Open sterile disinfectants left indefinitely in classified areas

    Use of non-sterile disinfecting agents and cleaning wipes in the ISO 5 area and classified areas. Specifically, sterile (b)(4) wipes, bottles of sterile (b)(4) solution, and bottles of sterile (b)(4) remained open in the ISO 7 Buffer Rooms indefinitely while technicians actively used these items to disinfect and clean items that entered the ISO 5 LHF and ISO 7 Buffer Rooms on 09/15/26.

  4. 4

    Inadequate hazardous drug containment and cleaning

    Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, A. Nonsterile production technicians in the hazardous room do not always follow the deactivate, decontaminate, and clean process. Technicians did not adequately deactivate or decontaminate mixing blades, spatulas, glass beakers, and various (b)(4) removable parts that directly contact hazardous drugs. I watched multiple technicians wipe equipment and utensils with a single-use wipe (b)(4) with (b)(4) or (b)(4), immediately rinse the items with tap water, wash the items with tap water and (b)(4), and then place them on a drying rack. B. Red spatula with unknown white residue and powder, black spatula with unknown white residue and powder, (b)(4) with unknown white residue and a brownish particulate, scraper with unknown white residue and powder. All these items were observed to be comingled with other utensils and were designated clean and ready for use. C. The mouse, keyboard, (b)(4) scanner, and (b)(4) at the workstation for each of the (b)(4) (b)(4) in the hazardous production room were not deactivated, decontaminated, and cleaned adequately. I watched a technician use the mouse at the workstation next to Hood on multiple days. The mouse contained visible white residue in the seams every time I examined it. I watched multiple technicians remove their hands from the (b)(4) during active production and then use items at the workstation without decontaminating or changing gloves. D. (b)(4) Hood had a hole and an about two-inch-long open crack on the back wall of the unit. There was also a buildup of residue on the left side panel above the hinge for the front panel. E. The work surfaces in (b)(4) Hood, Hood, Hood and Hood contained excessive scratches, pits, and other wear that made the surfaces not smooth and easily deactivated, decontaminated, and cleaned.

  5. 5

    Inadequate dynamic smoke studies for airflow

    Smoke studies were inadequately performed under dynamic conditions. Specifically, smoke studies did not introduce smoke into the entire ISO 5 LFH to confirm unidirectional airflow throughout the aseptic processing area. Additional technicians in the ISO 7 Buffer Rooms during the smoke studies were stationary which was not representative of routine production. I reviewed the most recent smoke studies completed in April 2026 for Hood and Hood in Lane and completed in May 2026 for Hood and Hood in Lane. Technicians produced all sterile injectable drugs in these LFH which includes more than (b)(4) sterile drug vials in the previous three months.

  6. 6

    Difficult to clean production surfaces and sinks

    Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces. Specifically, A. There was visible adhesive facing upward on the partially unsecured tape attempting to secure the damaged height adjustment control panel underneath the worksurface of ISO 5 Hood. The exposed adhesive was within six inches of the seated technician filling multiple lots of Semaglutide 2.5 mg/mL on 09/15/26. B. There is a large glassware washing sink and a small hand washing sink in the ISO 8 Anteroom. Technicians wash and dry all glassware used during sterile compounding/formulation in the ISO 8 Anteroom before it is transferred to another room for (b)(4) preparation. Sterile production technicians gown within a few feet of these sinks. The ISO 8 Anteroom is connected to both ISO 7 Prep Rooms used to formulate drugs. Both ISO 7 Prep Rooms are connected to ISO 7 Buffer Rooms that contain ISO 5 LFHs used to sterile (b)(4) and fill finished drugs. C. There was apparent corrosion and damage to the bottom of multiple (b)(4) door frames where they met the floor in the cleanroom.

  7. 7

    Improper gowning near glassware washing sink

    Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated. Specifically, I watched a sterile production technician don sterile garb inside the ISO 8 Anteroom about two to four feet away from a laboratory support technician who was manually washing about 15 soiled glassware items in the approximately four-foot-wide sink. The production technician entered the Lane ISO 7 Prep Room. Flow of materials and personnel: ISO 8 anteroom → ISO 7 Prep Rooms → ISO 7 Buffer Rooms.

  8. 8

    Media fills not simulating worst-case conditions

    Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions. Specifically, media fills are not always conducted under the most challenging and stressful conditions. Technicians work (b)(4) shifts, but there is no requirement for media fills to occur at the end of a technician's shift when they are presumably most fatigued. The end of the shift ensures the technician would have interacted with the most materials, personnel, environment, and other items that could contribute to particulates, microorganisms, or other contaminants in the media fill.

  9. 9

    Stools and benches excluded from environmental monitoring

    Inadequate routine environmental monitoring in the classified areas. Specifically, stools positioned at all (b)(4) ISO 5 LFH are not included in the EM surface sample program. I observed technicians in the Lane ISO 7 buffer room and the Lane ISO 7 buffer room directly contact a stool with their gloved hands during filling operations for sterile injectable drugs. Technicians sit on the stools while filling. Technicians sit on a bench in the ISO 8 anteroom while donning sterile gowning. The anteroom bench is approximately than one-foot-away from the hand washing sink and four-foot-away from the glassware washing sink.

  10. 10

    Damaged personnel monitoring plates still incubated

    Lack of adequate personnel sampling. Specifically, a pharmacist who was performing (b)(4) assessment on 09/16/26 cracked both (b)(4) plates all the way across and through the depth of the (b)(4). Also, an approximately 1-inch piece broke off the side of the (b)(4) plate lid and fell onto the (b)(4) surface. The QA Technician administering the assessment did not invalidate the assessment and incubated the damaged plates. Damaged (b)(4) surface can inhibit growth of microorganisms.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.