Wanbury Limited
K.Illindalaparru, Iragavaram Mandal, West Godavari District, Tanuku, India
FEI 3002980818DUNS 650449981
Company: Wanbury Limited · Linked by exact D-U-N-S match (918517165) in FDA registration data
FDA has 5 inspections on file for Wanbury Limited in Tanuku, India (FEI 3002980818), from 2009 to 2026. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.
2 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2026. Its registrant, Wanbury Limited (D-U-N-S 918517165), has registered 1 other site.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 5, 2009–2026
- 1 OAI · 3 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 5
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest Jul 21, 2026
- Warning letters
- None on file
- Import refusals
- 2 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Process validation deficient raw material amounts
Process validation is deficient in that an unexpected amount of raw material than specified in your validated process was needed in order to produce an active pharmaceutical ingredient. Specifically, Deviation 001/23, covering (b)(4) lower levels of (b)(4) was needed to than required by your validated process. A) For (b)(4) batch (b)(4) less than (b)(4) is needed to of (b)(4) However, at step number (b)(4) was needed, for a total of (b)(4) only (b)(4) (b)(4) less than the validated process requires. B) For (b)(4) batch (b)(4) is needed to less than (b)(4) of (b)(4) However, at step number (b)(4) batches, reports (b)(4), your batch production record specified that no (b)(4) (b)(4) of a minimum of (b)(4) This is approximately (b)(4), your batch production record specified that no (b)(4) (b)(4) (b)(4), only (b)(4) was needed, for a total of (b)(4) of a minimum of (b)(4). This is approximately (b)(4) less than the validated process requires. (b)(4) However, your investigation reported that the root cause is "batch to batch variability" without reasoning, respectively, of the required amount wasn't needed for this why approximately (b)(4) process.
- Observation 2
Equipment cleaning procedures not followed
Established procedures are not followed for equipment cleaning, and cleaning records do not accurately reflect actual cleaning activities. Specifically, A) On July 13, 2026, during a facility walkthrough of the API manufacturing area, Block (b)(4) significant quantities of visible product residues of (b)(4) were observed on both the external and internal surfaces of (b)(4) Equipment following (b)(4) processing operations for Batch Nos. (b)(4). Despite the presence of these significant residues, the equipment usage and cleaning logbooks reflected that cleaning had been completed, and equipment status labels indicated the equipment was in a "Cleaned" state. Physical inspection of the affected equipment and interviews with the operators confirmed that the required batch-to-batch cleaning procedure, as specified in SOP No. W3/PR(b)(4)/041, had not been performed. (b)(4) had no designated provision in the Additionally, Batch Production Record (BPR) or any equipment logbook to record cleaning activities. No separate was not documented. logbook for the (b)(4) was in place, and cleaning of the (b)(4) B) On July 13, 2026, during the manufacture of (b)(4), Batch No. (b)(4), the equipment usage and cleaning logs for (b)(4) contained no documentation demonstrating that batch-to-batch cleaning was performed prior to commencement of the subject batch, as required by SOP No. W3/PR(b)(4)/007. (b)(4) Furthermore, the equipment status labels on reflected the previous batch information rather than the current batch being processed, indicating that the equipment status had not been updated prior to commencement of manufacturing operations for Batch No. (b)(4) C) On July 13, 2026, during the facility walkthrough of Block (b)(4) the equipment status of (b)(4) changed three times within approximately 60 minutes during the inspection, from no (b)(4) recorded status, to "Cleaned," to "Under Process." Upon observing the "Cleaned" status, the investigator requested that the firm open the (b)(4) to verify cleanliness. As firm personnel were preparing to open the (b)(4), visible fumes were observed emanating from the vessel. When questioned, the operator disclosed that the (b)(4) with approximately (b)(4) of recovered (b)(4) had already been (b)(4) intended for Batch No. (b)(4) and subsequently changed the equipment status to "Under Process." The (b)(4) contained a significant quantity of solvent at the time the status indicated "Cleaned," and did not reflect the actual condition of the equipment. Status changes were made reactively during the inspection rather than contemporaneously with manufacturing operations.
Show observations 3 to 6
- Observation 3
Mandatory BPR step skipped not documented
A mandatory process step specified in the approved Batch Production Record (BPR) was not performed, and manufacturing activities were not contemporaneously documented. Specifically, (b)(4) On July 13, 2026, during the manufacture of, Batch No. (b)(4), the mandatory process requirement of (b)(4) (b)(4) (Operation No. (b)(4)) per BPR No. (b)(4) was not performed. Following to the required (b)(4), the process was advanced directly to completion of (b)(4) (b)(4) without completing the (b)(4) operations using equipment required holding period. Furthermore, the initiation of (b)(4) activity was not recorded in the relevant BPR at the time of execution, resulting in incomplete and non-contemporaneous documentation of a manufacturing step.
- Observation 4
Recovered solvent accountability records inadequate
Adequate records are not maintained to ensure complete accountability and traceability of recovered solvents used in the manufacture of APIs. Specifically, During the inspection, the firm operator confirmed that (b)(4) of recovered (b)(4) (b)(4) had been and identified the storage (b)(4) for Batch No. (b)(4) tanks from which the solvent was drawn; however, firm management was unable to reconcile the quantity of recovered (b)(4) transferred from the identified storage tanks against the quantity (b)(4) (b)(4) and could not provide verifiable contemporaneous documentation to support the solvent quantity transferred or demonstrate complete material accountability for the (b)(4). Upon further verification of recovered (b)(4) reconciliation records, your firm identified a discrepancy in solvent accountability. A total of (b)(4) was generated under Batch No. of recovered (b)(4) (b)(4). For Batch No. (b)(4) was drawn from Batch No. (b)(4) and an additional (b)(4), together totaling (b)(4) was drawn from a separate recovery batch, Batch No. (b)(4) consumed. Accordingly, an expected balance of (b)(4) should from Batch No. (b)(4) Physical verification of these tanks have remained available in storage tanks (b)(4) that could not be reconciled revealed only (b)(4) present, representing an apparent shortfall of (b)(4) at the time of inspection.
- Observation 5
Inaccurate incomplete lab records review
Laboratory records are not accurate and/or complete, and are not reviewed by a second person. Specifically, (b)(4) A) Growth Promotion Test (GPT) results for batch (b)(4) were not recorded, and the analytical data sheet was not completed prior to media release; nevertheless, this media was released and used for finished product microbiological testing. (b)(4) B) Growth Promotion Test (GPT) results for batch (b)(4) medium, in were recorded as colony counts despite the fact that GPT was performed using a (b)(4) which colony enumeration is scientifically impossible; these erroneous results were signed by both the analyst and the reviewer, and the media was subsequently used for microbiological testing of multiple API batches. C) Additionally, during the inspection on 13th July 2026, the microbiology reviewer had not signed the water testing, and the microbiological test plates were analytical records contemporaneously for (b)(4) and destroyed prior to review and sign-off by the reviewer.
- Observation 6
Inadequate microbiological risk investigation procedures
Inadequate Microbiological Risk Management and Non-Conformance Investigation Procedures. Specifically A) Your firm has not conducted a documented risk-based impact assessment to evaluate the microbiological risks associated with (b)(4) water system, including a failure to evaluate the need for Burkholderia cepacia complex testing. water microbiological B) Your firm's non-conformance investigation procedures for both (b)(4) testing (SOP W3/QC/MB/GEN/015) and finished product microbiological testing (SOP W3/QC/MB/FP/003) do not require organism identification following an excursion at the alert limit, action limit, or out-of-specification stage.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Jul 21, 2026. It asked for a Form 483.
Inspection ending Jul 17, 2026OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jul 21, 2026FDA-FOIA-2026-6945Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 1 section of 21 CFR in FDA’s published citations for 1 of this facility’s 5 inspections.
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002980818, one row per refused product line.
2 refusals from 2017-08-24 to 2018-04-25 · charged UNAPPROVED on 1, DIRSEXMPT on 1 · no FDA sample analysis
FDA firm profile- 2018-04-25
MISCELLANEOUS PATENT MEDICINES, ETC.66VDA99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-5085504-6/11/3
- 2017-08-24
SEROTONIN INHIBITOR N.E.C.65WCT99
DIRSEXMPT 502(f)(1), 801(a)(3); MISBRANDING
Division of Southeast ImportsWQ8-0608894-1/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- Wanbury LimitedD-U-N-S 918517165
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Wanbury Limited (D-U-N-S 918517165) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Wanbury LimitedPatalganga, India · FEI 30032271484 inspections4latestJun 14, 2024NAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3002980818 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3002980818. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.