Equipment cleaning and cleaning validation in FDA Form 483 observations

Cleaning procedures for manufacturing equipment, the studies that show they work, and the residues, swabs and logs that prove each cleaning. FDAgent finds 197 such observations in 144 Form 483s issued to 138 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
197
Each quoted below
Form 483s
144
Posted by FDA
Facilities
138
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 63 in 2026

Equipment cleaning observations in Form 483s by inspection year
YearObservations
20081
20090
20100
20110
20120
20130
20141
20151
201610
201715
201820
20195
20205
202110
20227
202322
202413
202524
202663

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.6721 CFR 211.182

The same entries the equipment cleaning topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“cleaning validat*” · “validat* … cleaning” · “cleaning procedure*” · “cleaning process*” · “cleaning record*” · “cleaning log*” · “cleaning agent*” · “cleaning verification” · “cleaning stud*” · “cleaning method*” · “cleaning effectiveness” · “not cleaned” · “not adequately cleaned” · “not properly cleaned” · “residue*” · “swab*” · “carry over” · “carryover”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 197 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Lyophilization Services of New England, Inc. dba PCI Pharma ServicesInspection ended Jun 10, 2026 · FEI 3008546445 · Observation 4

    Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, utilities in support of (b)(4) drug product are not monitored in assurance the qualified validated state is maintained. Equipment and facilities used in the manufacture of (b)(4) drug product at (b)(4) are not adequately …

    Opens with FDA's citation wording for 21 CFR 211.67(a)Read the Form 483 →

  2. Shanghai Henlius Biopharmaceutical Co., Ltd.Inspection ended May 20, 2026 · FEI 3016529861 · Observation 4

    Your firm's cleaning validation programs for manufacturing equipment and components are inadequate in demonstrating that equipment used in drug substance and drug product manufacturing can be consistently cleaned to prevent contamination or carryover. Specifically, a. Your firm's (b)(4) cleaning validation for (b)(4) and (b)(4) used in the manufacture of (b)(4) drug substance did not include swab sampling or visual inspection of the internal …

    Contains “cleaning validat*”Read the Form 483 →

  3. VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 2

    … intended to be sterile in the same ISO 5 area and uses [(illegible)] with a [(illegible)] time, as the cleaning/sanitizing agent to inactivate beta-lactam residues only [(illegible)] in [(illegible)] in the non-hazardous production area. This frequency is inadequate to prevent cross-contamination.

    Contains “residue*”Read the Form 483 →

  4. VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 8

    … C) At least [(b)(4)] protruding fire sprinklers located in the ISO 7 ante and buffer rooms were observed not cleaned since around 2020. Additionally, the screw, cameras, and WiFi device on the ceilings of the buffer rooms (room [(b)(4)]) were not documented as cleaned. The buffer rooms contain the ISO 5 areas that are used to produce drug products intended to be sterile. D) On 04/28/2026, Bluetooth speakers were observed on the workbench of the …

    Contains “not cleaned”Read the Form 483 →

  5. QuVa Pharma IncInspection ended May 4, 2026 · FEI 3012053582 · Observation 1

    … On 4/20/2026, during a site walk-through cleanroom, I observed a "black residue" near the drug components, utensils, drug product containers, and finis[illegible] within all ISO 7 cleanrooms. Your firm entire [(b)(4)] located within the ISO 7 cleanroom. C. Your firm's dynamic ISO 5 LAFH/BSC smoke studies were found to [illegible]. Smoke studies within the ISO 5 LAFH/BSCs fail to adequately assess laminar air flow patterns for actual production …

    Contains “residue*”Read the Form 483 →

  6. QuVa Pharma IncInspection ended May 4, 2026 · FEI 3012053582 · Observation 2

    … 7 Cleanroom Suite 7, ISO 5 LAFH numbered [illegible], your compounding technician found on the ISO 5 LAFH grate in front [illegible] a brown to black foreign residue contaminant, later within an investigation identified [illegible]. The sealant [illegible]. The sealant is applied during the HEPA filt[er] [illegible] particulates from the degradation may become an airborne contaminate affecting first quality used during aseptic processing of …

    Contains “residue*”Read the Form 483 →

  7. Nice-Pak Products, LLCInspection ended Apr 20, 2026 · FEI 1822410 · Observation 1

    Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, You manufacture multiple non-sterile OTC drug products and cosmetic products on non-dedicated equipment, including manufacturing Lines and However, cleaning validation studies have not been performed for this shared equipment to demonstrate …

    Opens with FDA's citation wording for 21 CFR 211.67(b)Read the Form 483 →

  8. Cliantha Research LimitedInspection ended Apr 17, 2026 · FEI 3017682080 · Observation 5

    … Disclosed chromatograms carry over co-eluting with main compound found to be due to short run time (7 minutes). An investigational run (re-injection identified as Investigation (b) (4)) was performed on 10May2025 performed with sample trials. Corrective action was addressed by changing run time to 10 minutes. The informal investigation was reported as part of the remark section of the analytical worksheet, with no quality unit management review, …

    Contains “carry over”Read the Form 483 →

  9. Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 4

    … Recovery studies have not been performed that show using one swab (b)(4) of a (b)(4) (b)(4) gives adequate recovery.

    Contains “swab*”Read the Form 483 →

  10. Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 6

    Written procedures for cleaning and maintenance fail to include assignment of responsibility, description in sufficient detail of methods, equipment and materials used and description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance. The following discrepancies were noted during the review of cleaning activities which took place in the filling room on 8Apr2026. …

    Opens with FDA's citation wording for 21 CFR 211.67(b)Read the Form 483 →

  11. Pharmaneek IncInspection ended Apr 8, 2026 · FEI 3014484244 · Observation 1

    Hazardous drugs were produced without providing adequate containment segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, The current cleaning process is deficient for the following reasons and does not provide assurance that hazardous drug product residue and cleaning agent residue are adequately removed from reusable glassware and utensils used in production of both …

    Contains “cleaning process*”Read the Form 483 →

  12. Fujifilm Diosynth Biotechnologies USA Inc.Inspection ended Mar 27, 2026 · FEI 3000718852 · Observation 1

    … Your firm lacks scientific justification for failing to ensure that all cleaning agents used in controlled environments are purchased sterile. For example, you have not ensured that (b) (4) which is used as (b) (4) disinfectant for (b) (4) application in these areas to include ISO-5 environments is sterile. Drug substances produced in your facility are intended for the manufacture of parenteral drug products.

    Contains “cleaning agent*”Read the Form 483 →

  13. Cerovene Inc.Inspection ended Mar 23, 2026 · FEI 3005890568 · Observation 1

    OBSERVATION 1 (Repeat) Equipment and utensils are not cleaned, maintained at appropriate intervals to prevent malfunctions contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, During the inspection, we observed the following equipment cleaning deficiencies for equipment identified as having been cleaned: A. On 03/16/2026, we observed (b) (4) was being stored directly on the (b) (4) …

    Contains “not cleaned”Read the Form 483 →

  14. Cerovene Inc.Inspection ended Mar 23, 2026 · FEI 3005890568 · Observation 3

    … MTR _(b) (4) | able standard (by@) 2024 36 Working dissolution standard Intermediate standard May 30, 2025 Method Validation MVR_Soap_Cleaning_201 Soap (Cleaning Validation) Working standard September 18, 2025 (b) (4) Intermediate No date (b) (4) Method Transfer API standard (b) (4) Impurity (b) (4) (b) (4) working (b) (4) content 2025 17 Impurity (b) (4) ‘working standard Impurity (b) 4) ‘working standard Impurity (b) (4) working standard …

    Contains “cleaning validat*”Read the Form 483 →

  15. Spectrum Laboratory Products Inc.Inspection ended Mar 20, 2026 · FEI 2020632 · Observation 1

    Your quality unit failed to record, review, and approve all appropriate quality-related documents at the time activities are performed. Specifically, During my inspection, I reviewed your Laboratory Cleaning Records (QAF877) for all available months in 2025 and 2026. These records are used to document laboratory cleaning activities as required by your SOP QC-W-8.22, Section 5.9, which states: "(b)(4) cleaning activities shall be documented in …

    Contains “cleaning record*”Read the Form 483 →

  16. Spectrum Laboratory Products Inc.Inspection ended Mar 20, 2026 · FEI 2020632 · Observation 2

    … The hoods exhibited corrosion, permanent staining, flaking paint, and accumulation of residue and dust. These hoods are used for reagent preparation and analytical testing of APIs and raw materials. The condition of these hoods presents a potential risk of contamination to materials and test results. b) Inadequate Cleaning Procedures: Your SOP QC-W-8.22, "Analytical Laboratory Cleaning," does not specify approved cleaning agents or sanitizing …

    Contains “residue*”Read the Form 483 →

  17. Spectrum Laboratory Products Inc.Inspection ended Mar 20, 2026 · FEI 2020632 · Observation 3

    Your firm failed to adequately validate written procedures for cleaning and maintenance of equipment, and failed to monitor cleaning procedures at appropriate intervals after validation. Specifically: a) Outdated Cleaning Validation: Your last cleaning validation for production areas was performed in 2001, representing a 25-year gap between validations. This validation may not be representative of the current operations, products, equipment, and …

    Contains “validat* … cleaning”Read the Form 483 →

  18. Bausch and Lomb IncorporatedInspection ended Mar 20, 2026 · FEI 1000113778 · Observation 2

    … in the Aseptic Compounding Rooms (b) (4) on the floor near (b) (4) (sample site (b) (4)1) and during your Cleaning Validation C630-H-00; PARTS WASHER in the rinse solution at the (b) (4). C. Your firm failed to identify gram negative environmental isolates from (b) (4) and (b) (4) systems even when action and alert limits are exceeded. The exceeded alert and action limit isolates are only characterized as "Absence Indicator Organisms." Between …

    Contains “cleaning validat*”Read the Form 483 →

  19. Accura-Pac, Inc.Inspection ended Mar 5, 2026 · FEI 1818911 · Observation 3

    Records are not kept for the cleaning of equipment. Specifically, Your firm has established and validated a dirty hold time (DHT) of (b) (4) for |] compounding tanks in the (b) (4) Compounding Area, which are used in the manufacture of drug products and cosmetics. However, the logbooks associated with these compounding tanks do not document the start and stop times for tank usage and cleaning. There are no controls in place to record how many …

    Opens with FDA's citation wording for 21 CFR 211.67(c)Read the Form 483 →

  20. GSK Vaccines GmbHInspection ended Feb 27, 2026 · FEI 3001314775 · Observation 1

    Your firm has not validated the cleaning procedures for dedicated equipment used in the manufacture of Aluminum Hydroxide adjuvant to prevent contamination or carry-over. This adjuvant is a component of your licensed U.S. products including (b)(4) Infanrix, Boostrix, Kinrix, and Pediarix. Specifically, your cleaning validation and monitoring program for the aluminum hydroxide adjuvant production suite ((b)(4) and (b)(4)) is inadequate. You have …

    Contains “validat* … cleaning”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about equipment cleaning in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.