Skip to content

VA San Diego Healthcare Systems

California

FEI 2071629

FDA has 7 inspections on file for VA San Diego Healthcare Systems in California (FEI 2071629), from 2009 to 2026. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 11 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
7, 2009–2026
0 OAI · 0 VAI · 6 NAI
Inspections with 483 observations shown
1 of 7
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 11 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Incomplete smoke studies

      Smoke studies were inadequately performed under dynamic conditions. Specifically, Your firm did not conduct smoke studies under dynamic conditions, simulating worst-case production activities, including all components, materials, and equipment present during actual or routine aseptic operations, to demonstrate unidirectional airflow within the ISO 5 area(s) for the following equipment: 04/08/2026 - Hazardous [illegible] - Biologic Safety Cabinets (BSC) - SN:[illegible] 03/11/2026 - Non-Hazardous - Laminar Flow Hood (LAFH) - SN:[illegible] and [illegible] 04/23/2026 - Operating Room (OR) Segregated [illegible] - Compounding Aseptic [illegible] - SN:[illegible] 04/23/2026 - Intensive Care Unit (ICU) Segregated [illegible] - Compounding Aseptic [illegible] - SN:[illegible] A) For example, your smoke study of the sterile hazardous room [(b)(4)] did not introduce smoke to visualize airflow at the equipment and workflow management system containing the scale and camera for production operations. Your smoke study from 04/08/2026 did not include materials staged during aseptic operations including but not limited to a sterile prep mat, syringes, sterile wipes, [(D)(4)] prep tray for materials, closed transfer device, and [(15)(4)] plate and washer over the ISO 5 grille. The smoke study videos for BSC SN [(b)(4)] and [(b)(4)] (hazardous room [(b)(4)]) were 58 seconds and 57 seconds in duration, respectively, and did not span the entire hood workspace, providing incomplete visualization of airflow throughout the critical zone. B) The smoke study conducted on 03/11/2026 for the non-hazardous LAFH [(o)(4)] in room [(b)(4)] did not include equipment and materials staged during normal operations including but not limited to the equipment and workflow management system with protocol for drug production, scale, camera, and for production operations, hanging IV bags, [(D)(4)] vial reconstitution mixer, vials, beaker, handheld scanner with base, and printing of labels. The smoke study videos for non-hazardous LAFH [(6)(4)] were 16 seconds, 29 seconds, and 17 seconds in duration, respectively. Only half of the hood workspace was captured in the video, and the operator's positioning blocked visualization of aseptic connections receiving first air. C) The smoke study conducted on 04/23/2026 for the segregated [(b)(4)] in the ICU (room [(o)(4)]) demonstrated that there was activity being performed outside where the smoke was introduced. Therefore, the aseptic critical sites and open product containers receiving unidirectional first air as required during routine aseptic operations was obscured. D) The smoke study videos did not demonstrate that non-ISO 5 air was not introduced into the critical zone, namely BSCs. We observed the sterile production of bortezomib 2.7 mg, label # [illegible] (produced in BSC [(b)(4)] in the hazardous room [(b)(4)]) and ertapenem 1 gram in normal saline mini-bag 50 mL, label [(o)(4)] (produced in LAFH [(b)(4)] in the non-hazardous room [(b)(4)]) on [(b)(4)] without conducting smoke studies under dynamic conditions.

    2. Observation 2

      Beta-lactam cross-contamination risk

      Beta-lactam drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, Beta-Lactam drug products are produced in the same ISO 5 hoods as non-beta-lactam drug products intended to be sterile. The following beta-lactam drugs were observed being produced in your LAFH hood include, but are not limited to: - ceftaroline fosamil 300 mg in D5W 100 mL - ampicillin 2 gm in Normal Saline Mini-Bag 100 mL - ampicillin/sulbactam 3 gm in Normal Saline Mini-Bag 100 mL - ertapenem 1 gm in Normal Saline Mini-Bag 50 mL - meropenem 1000 mg in Normal Saline Mini-Bag 50 mL - meropenem 2000 mg in Normal Saline 100 mL Your firm performs cleaning with only [(b)(4)] between the production of beta-lactam and non-beta lactam drug products intended to be sterile in the same ISO 5 area and uses [(illegible)] with a [(illegible)] time, as the cleaning/sanitizing agent to inactivate beta-lactam residues only [(illegible)] in [(illegible)] in the non-hazardous production area. This frequency is inadequate to prevent cross-contamination.

    Show observations 3 to 11
    1. Observation 3

      Unidentified HEPA filter staining

      Contamination was observed in your production area. Specifically, On 04/29/2026, unidentified brown staining was observed on the HEPA filter in the ISO 5 non-hazardous LAFH production hood (SN: [(b)(4)]). Your firm was unable to identify the source of the staining or confirm whether it affected filter integrity, air quality, or aseptic conditions in the ISO 5 area. The duration of this condition is unknown.

    2. Observation 4

      Supplies not disinfected at transitions

      Lack of disinfection of supplies at each transition from areas of lower quality air to areas of higher quality air. Specifically, A) On 04/27/2026, 04/28/2026, and 04/29/2026, [(b)(4)] operators in both the hazardous and non-hazardous production rooms failed to wipe down materials with an appropriate disinfectant (e.g., [(illegible)]) when transitioning those materials from the ISO 7 buffer room environment into the ISO 5 critical zone during the production of luspatercept-aamt 50 mg, label # [illegible]. B) On 04/28/2026, a re-purposed [(illegible)] bottle, labeled '[(illegible)]' used to discard leftover fluid generated during aseptic processing operations, was observed used within the ISO 5 critical zone without observed disinfection upon transfer from the ISO 7 buffer room after being emptied. The bottle was reused and stored in the ISO 5 hood over multiple days. During aseptic processing activities, the cap has to be removed by the technician, and the bottle handled each time liquid is deposited inside. The operator was observed discarding liquid into the reused bottle. On [(b)(4)] bortezomib 2.7 mg, label [illegible] was produced with the re-used fluid discard bottle present in the ISO 5 critical area. C) The wearable, [(15)(4)] communication device is inconsistently worn by operators entering the ISO 5 environment during aseptic processing of sterile drug products, with some operators wearing the device over their gown and others wearing it under their gown, resulting in direct or potential exposure of the device to the ISO 5 environment. These devices are used throughout the hospital, including in patient care areas; however, they are only cleaned with [(b)(4)] prior to being worn into the cleanroom. No sporicidal agent is used to clean these devices, and no environmental monitoring is performed to assess the contamination risk they may introduce.

    3. Observation 5

      Operators resting on work surface

      An operator rested their arms on the work surface of the hood during aseptic production. This practice may introduce contamination into the ISO 5 work area. Specifically, A) In the non-hazardous production room [(6)(4)] operators were observed resting their hands directly on the ISO 5 workbench surface on 04/29/2026 during the production of micafungin 100 mg in normal saline 100 mL. B) On 04/28/2026, the operator's elbows were observed resting on the edge of the front grille of the ISO 5 Biological Safety Cabinet (BSC).

    4. Observation 6

      Glove hygiene after touching outside surfaces

      Personnel were observed touching equipment or other surfaces located outside of the ISO 5 area with gloved hands and then proceeding with aseptic processing without changing or sanitizing gloves. Specifically, On 04/28/2026 during the production of bortezomib 2.7 mg, label # [illegible], an operator failed to sanitize or change their gloved hands with [(6)(4)] after touching the computer keyboard and mouse within the ISO 7 buffer room prior to going back into the ISO 5 critical area to continue aseptically processing drug product intended to be sterile. Your SOP only specifies [(b)(4)] surfaces. We did not observe your third party cleaners cleaning and sanitizing your keyboards, mouse, and handheld scanner.

    5. Observation 7

      Rapid movements disrupting airflow

      Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow. Specifically, An operator was observed spraying their gloved hands with [(b)(4)] under the ISO 5 hood and then rapidly moved their hands to dry within the critical area, causing disruption of unidirectional airflow on 04/28/2026 during the production of bortezomib 2.7 mg, label [illegible]. The operator's hands moved rapidly over materials and components used during production.

    6. Observation 8

      Difficult-to-clean/dirty equipment

      Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces. Specifically, A) The [(15)(4)] plate and washer located on the front grille of BSC SN: [(6)(4)] and [(15)(4)] (hazardous room [(b)(4)]) are difficult to clean and may harbor and shed particulates and microbial contamination into the ISO 5 environment. This screw and washer were left by the firm's engineering to the BSC grill and not part of the smoke studies, therefore there is no assurance that this is not interfering in the functionality or causing turbulence in the BSC. B) On 04/30/2026, during the production of doxorubicin 48 mg in normal saline 250 mL, chipped and protruding paint was observed on the walls of the ISO 7 buffer room. C) At least [(b)(4)] protruding fire sprinklers located in the ISO 7 ante and buffer rooms were observed not cleaned since around 2020. Additionally, the screw, cameras, and WiFi device on the ceilings of the buffer rooms (room [(b)(4)]) were not documented as cleaned. The buffer rooms contain the ISO 5 areas that are used to produce drug products intended to be sterile. D) On 04/28/2026, Bluetooth speakers were observed on the workbench of the ISO 7 buffer room, across from the ISO 5 laminar airflow hood (LAFH) used for hazardous sterile production (room [(6)(4)]). E) On 04/28/2026 and 04/29/2026, the electronic workflow equipment located within each non-hazardous ISO 5 LAFH (room [(15)(4)]) was observed to not be wiped down with an appropriate disinfectant (e.g., [(6)(4)]) between individual batches. The electronic workflow equipment within each hazardous BSC (room [(b)(4)]) was observed to not be wiped down with an appropriate disinfectant (e.g., [(6)(4)]) between individual batches.

    7. Observation 9

      Exposed hair/skin in ISO 5

      Personnel performed aseptic manipulations with exposed hair or skin. Specifically, A) On 04/27/2026 and 04/29/2026, multiple operators were observed aseptically processing drug products intended to be sterile in the ISO 5 laminar airflow hood (LAFH) with exposed hair, including during the production of daptomycin 670 mg in sodium chloride 0.9%, 36.6 mL, label # [(15)(4)] in room [(6)(4)]. B) On 04/29/2026, one operator was observed inserting their head, including the exposed skin of their forehead, and eyeglasses into the ISO 5 critical zone during the production of luspatercept-aamt 50 mg, label [illegible]. These eyeglasses are only cleaned with [(b)(4)] before being brought into the ISO 7 buffer area and are worn throughout the hospital and patient care areas. No sporicidal agent was used to clean these items and no environmental monitoring was performed to assess the contamination risk they may introduce.

    8. Observation 10

      Materials exposed to lower-quality air

      Materials were exposed to lower than ISO 5 quality air. Specifically, A) Sterile, lint-free wipes stored in an exposed, open condition were observed on the wall of the ISO 7 buffer rooms. At least [illegible] of the transparent boxes on the wall had broken hinges and were left open during production. The wipes, which were difficult to pull from the box, were sprayed with sterile [(b)(4)] in the ISO 7 buffer and then used to clean the ISO 5 workbench surface and to wipe materials transitioning from areas of lower quality air into the ISO 5 critical areas. B) Sterile, lint-free wipes were observed on the wall of the unclassified areas of the segregated ICU room [(o)(4)] by the sink.

    9. Observation 11

      Use of expired sterile gloves

      Personnel engaged in aseptic processing were observed wearing non-sterile gloves. Specifically, Operators were observed using expired sterile gloves (manufactured in 01/2022) during aseptic production of bortezomib 2.7 mg, label # [illegible] on 04/28/2026. There is no assurance that the gloves are intact and remain sterile. Your sterile glove manufacturer suggested that the gloves be used within [illegible] of the manufacturer date.

  2. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  3. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  4. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  5. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  6. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  7. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 2071629 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 2071629. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.