Skip to content

Cliantha Research Limited

Tp 86, Fp 28/1, Off S.P. Ring Road, Sarkhej, Cliantha Corporate, Ahmedabad, Gujarat, India

FEI 3017682080

FDA has 4 inspections on file for Cliantha Research Limited in Ahmedabad, Gujarat (FEI 3017682080), from 2021 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
4, 2021–2026
0 OAI · 1 VAI · 3 NAI
Inspections with 483 observations shown
1 of 4
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest Jul 23, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch MonitoringPosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate investigation of IS response

      1. The firm did not investigate significant variations in internal standard (IS) response across different studies consistently using criteria defined in SOP 100AB009 and SOP 100AB016. Specifically, the firm did not investigate a distinct inverse correlation between the analyte and IS responses in studies (b) (4) and (b) (4) (b) (4) because the IS responses met established criteria (IS response within +/- 40% of the mean IS response of CCs and QCs). However, the firm investigated multiple subjects in studies (b) (4) and (b) (4) (b) (4) where the IS response was lower than QC IS responses by (b) (4)% and the IS response criteria were met in all subjects investigated per SOP 100AB009 and SOP 100AB016.

    2. Observation 2

      Missing/uncorroborated sample source documentation

      2. The firm did not maintain all source documentation for bioanalytical studies. Specifically: a. Details of samples transferred from freezer FDI-53 to freezer FDI-27 on 12 Apr 26 were recorded on a scrap piece of paper found in the trashcan of the first-floor freezer room, including the time of transfer (14:21 to 14:24) for the following studies: (b) (4) Set II subject samples and QCs Set I subject samples Set I and Set III samples Set II subject samples and QCs Set II subject samples and QCs Sample movement details were subsequently transposed from the scrap paper to logbooks for freezers FDI-53 and FDI-27, and thus the logbooks are not the contemporaneous source documents. Add Continuation Page b. Partial details of samples transferred from freezer FDI-10 to freezer FDI-44 were recorded on a scrap piece of paper found in the trashcan of the first-floor freezer room for the following studies: • (b) (4) Set I • Set I • Set I No date or time was recorded on the scrap paper, so the date and time recorded in the logbooks for freezers FDI-10 and FDI-44 cannot be verified. The logbooks are not the contemporaneous source documents.

    Show observations 3 to 6
    1. Observation 3

      Missing sample volume accountability

      3. The firm was unable to account for missing sample volume in samples from studies (b) (4), (b) (4), and (b) (4). Specifically: a. In study (b) (4), aliquot 2 of subject (b) (6), period 4, sample 0.75hr was used for incurred sample reanalysis (ISR) because sufficient sample was not available in aliquot 1. However, only 100 uL from aliquot 1 of this sample was used during initial analysis of subject (b) (6) samples and the firm could not provide any accountability for use of the remaining of 300 uL out of 400 ul total sample volume in aliquot 1. b. In study (b) (4) the aliquot 1 samples for subject (b) (6), period 2, 16hr and subject (b) (6), period 1, 2hr (100 uL used for each of 2 analyses out of 400 uL total sample volume) did not have enough volume remaining to be used for ISR analysis and aliquot 2 was used for ISR. The firm could not provide any accountability for use of the remaining sample volume in aliquot 1. c. In study (b) (4), aliquot 2 of subject (b) (6), period 1, sample (b) (4) was used for ISR analysis because sufficient sample was not available in aliquot 1. However, 200 uL out of 700 uL total volume of aliquot 1 of this sample was used only once during initial analysis of subject (b) (6) samples and the firm could not provide any accountability for use of the remaining sample in aliquot 1.

    2. Observation 4

      Inaccurate bioanalytical reporting

      4. The firm reported inaccurate data in the bioanalytical report for study (b) (4) (b) (4). Specifically, Section 5.1.2 of the report stated that aliquot 2 samples were not used in sample analysis. However, the logbook for freezer FWI-06 (A-AL-25-503) documented retrieval of aliquot 2 samples from subjects (b) (6) and (b) (6) on 07 Oct 2025 for use in ISR analysis and subsequent return of the samples on the same date. Add Continuation Page

    3. Observation 5

      Quality unit inadequate investigation oversight

      5. Your Quality unit failed to perform thorough and/or adequate laboratory investigations (identified by firm as event or incident) as required by the control procedure 100AB014, Version 4, Laboratory Event Management, Effective date: 23Jun2025; to ensure the appropriate root cause, propose adequate corrective / preventive actions, scientific justification to invalidate original result and management of events for any bioanalytical phase of method validation/study sample analysis, which may impact the quality and integrity of the results. However, the investigation is generated and concluded by analyst, reported as part of the remark section of the analytical worksheet, with no quality unit management review, consent or approval. This discrepancy and/or practice is permitted by your Bioanalytical Laboratory, QC Laboratory and QA unit. Examples of deficiencies are evidenced as follows: a. During chromatographic run # 9 (for subject (b), and (b)) of study # (b) (4) (b) (4) injected on 08May2025 on instrument # AS-20. Disclosed that sample ID # (b) (4) and # (b) (4) chromatographic run contained no response for either of the (b) (4), or internal standard. An investigational run (re-injection identified as Investigation (b) (4)) was performed on 08May2025 that obtained both peak responses. The informal investigation was reported as part of the remark section of the analytical worksheet, with does not contain any quality unit management oversight, review, consent or approval. b. During the chromatographic run #11 (for subject (b), and (b)) and run # 12 (for subject (b), and (b)) of study # (b) (4) (b) (4) injected on 09May2025 on instrument AS-20- and AS-26, respectively. Disclosed chromatograms carry over co-eluting with main compound found to be due to short run time (7 minutes). An investigational run (re-injection identified as Investigation (b) (4)) was performed on 10May2025 performed with sample trials. Corrective action was addressed by changing run time to 10 minutes. The informal investigation was reported as part of the remark section of the analytical worksheet, with no quality unit management review, consent or approval. c. During the chromatographic run #27 (for subject (b), and (b)) of study # (b) (4) (b) (4) injected on 21May 2025 on instrument AS-20. Disclosed low peak area response for sample ST-6. An investigational run (re-injection identified as Investigation (b) (4)) was performed on 21May2025. The informal investigation was generated and concluded by analyst that event was due to instrument error and excluded from the results table. This was reported as part of the remark section of the analytical worksheet, with no quality unit management review, consent or approval. Add Continuation Page

    4. Observation 6

      Inadequate informed consent

      6. Legally effective informed consent was not obtained from a subject or the subject's legally authorized representative. Specifically, your general screening informed consent does not include a description of the specific procedures to be followed. You conducted mammograms, transvaginal ultrasounds, pap smears, and estradiol plasma concentrations on 48 enrolled subjects (plus extra subjects) prior to their study specific consent.

  2. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  3. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  4. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 23, 2026. Each one asked for a Form 483.

  • Inspection ending Apr 17, 2026VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jul 23, 2026FDA-FOIA-2026-7096Form 483· 1 of 2 sitesRecords released
  • Inspection date not given

    1 request. FDA released records in answer to a request for its Form 483 on May 26, 2026. FDAgent holds no copy that FDA posted.

    1. May 15, 2026FDA-FOIA-2026-4978Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Other FEIs recorded as Cliantha Research Limited

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3017682080 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3017682080. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.