FDA issued this Form 483 to Cliantha Research Limited in Ahmedabad, Gujarat (FEI 3017682080) at the end of a drug inspection that ran from April 13 to April 17, 2026. It lists 6 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jul 13, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection
Apr 13–17, 2026
Drugs · Bioresearch Monitoring
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Jul 13, 2026
87 days after the inspection
Facility
FEI 3017682080
Ahmedabad, Gujarat

The 6 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate investigation of IS response

    1. The firm did not investigate significant variations in internal standard (IS) response across different studies consistently using criteria defined in SOP 100AB009 and SOP 100AB016. Specifically, the firm did not investigate a distinct inverse correlation between the analyte and IS responses in studies (b) (4) and (b) (4) (b) (4) because the IS responses met established criteria (IS response within +/- 40% of the mean IS response of CCs and QCs). However, the firm investigated multiple subjects in studies (b) (4) and (b) (4) (b) (4) where the IS response was lower than QC IS responses by (b) (4)% and the IS response criteria were met in all subjects investigated per SOP 100AB009 and SOP 100AB016.

  2. 2

    Missing/uncorroborated sample source documentation

    2. The firm did not maintain all source documentation for bioanalytical studies. Specifically: a. Details of samples transferred from freezer FDI-53 to freezer FDI-27 on 12 Apr 26 were recorded on a scrap piece of paper found in the trashcan of the first-floor freezer room, including the time of transfer (14:21 to 14:24) for the following studies: (b) (4) Set II subject samples and QCs Set I subject samples Set I and Set III samples Set II subject samples and QCs Set II subject samples and QCs Sample movement details were subsequently transposed from the scrap paper to logbooks for freezers FDI-53 and FDI-27, and thus the logbooks are not the contemporaneous source documents. Add Continuation Page b. Partial details of samples transferred from freezer FDI-10 to freezer FDI-44 were recorded on a scrap piece of paper found in the trashcan of the first-floor freezer room for the following studies: • (b) (4) Set I • Set I • Set I No date or time was recorded on the scrap paper, so the date and time recorded in the logbooks for freezers FDI-10 and FDI-44 cannot be verified. The logbooks are not the contemporaneous source documents.

  3. 3

    Missing sample volume accountability

    3. The firm was unable to account for missing sample volume in samples from studies (b) (4), (b) (4), and (b) (4). Specifically: a. In study (b) (4), aliquot 2 of subject (b) (6), period 4, sample 0.75hr was used for incurred sample reanalysis (ISR) because sufficient sample was not available in aliquot 1. However, only 100 uL from aliquot 1 of this sample was used during initial analysis of subject (b) (6) samples and the firm could not provide any accountability for use of the remaining of 300 uL out of 400 ul total sample volume in aliquot 1. b. In study (b) (4) the aliquot 1 samples for subject (b) (6), period 2, 16hr and subject (b) (6), period 1, 2hr (100 uL used for each of 2 analyses out of 400 uL total sample volume) did not have enough volume remaining to be used for ISR analysis and aliquot 2 was used for ISR. The firm could not provide any accountability for use of the remaining sample volume in aliquot 1. c. In study (b) (4), aliquot 2 of subject (b) (6), period 1, sample (b) (4) was used for ISR analysis because sufficient sample was not available in aliquot 1. However, 200 uL out of 700 uL total volume of aliquot 1 of this sample was used only once during initial analysis of subject (b) (6) samples and the firm could not provide any accountability for use of the remaining sample in aliquot 1.

  4. 4

    Inaccurate bioanalytical reporting

    4. The firm reported inaccurate data in the bioanalytical report for study (b) (4) (b) (4). Specifically, Section 5.1.2 of the report stated that aliquot 2 samples were not used in sample analysis. However, the logbook for freezer FWI-06 (A-AL-25-503) documented retrieval of aliquot 2 samples from subjects (b) (6) and (b) (6) on 07 Oct 2025 for use in ISR analysis and subsequent return of the samples on the same date. Add Continuation Page

  5. 5

    Quality unit inadequate investigation oversight

    5. Your Quality unit failed to perform thorough and/or adequate laboratory investigations (identified by firm as event or incident) as required by the control procedure 100AB014, Version 4, Laboratory Event Management, Effective date: 23Jun2025; to ensure the appropriate root cause, propose adequate corrective / preventive actions, scientific justification to invalidate original result and management of events for any bioanalytical phase of method validation/study sample analysis, which may impact the quality and integrity of the results. However, the investigation is generated and concluded by analyst, reported as part of the remark section of the analytical worksheet, with no quality unit management review, consent or approval. This discrepancy and/or practice is permitted by your Bioanalytical Laboratory, QC Laboratory and QA unit. Examples of deficiencies are evidenced as follows: a. During chromatographic run # 9 (for subject (b), and (b)) of study # (b) (4) (b) (4) injected on 08May2025 on instrument # AS-20. Disclosed that sample ID # (b) (4) and # (b) (4) chromatographic run contained no response for either of the (b) (4), or internal standard. An investigational run (re-injection identified as Investigation (b) (4)) was performed on 08May2025 that obtained both peak responses. The informal investigation was reported as part of the remark section of the analytical worksheet, with does not contain any quality unit management oversight, review, consent or approval. b. During the chromatographic run #11 (for subject (b), and (b)) and run # 12 (for subject (b), and (b)) of study # (b) (4) (b) (4) injected on 09May2025 on instrument AS-20- and AS-26, respectively. Disclosed chromatograms carry over co-eluting with main compound found to be due to short run time (7 minutes). An investigational run (re-injection identified as Investigation (b) (4)) was performed on 10May2025 performed with sample trials. Corrective action was addressed by changing run time to 10 minutes. The informal investigation was reported as part of the remark section of the analytical worksheet, with no quality unit management review, consent or approval. c. During the chromatographic run #27 (for subject (b), and (b)) of study # (b) (4) (b) (4) injected on 21May 2025 on instrument AS-20. Disclosed low peak area response for sample ST-6. An investigational run (re-injection identified as Investigation (b) (4)) was performed on 21May2025. The informal investigation was generated and concluded by analyst that event was due to instrument error and excluded from the results table. This was reported as part of the remark section of the analytical worksheet, with no quality unit management review, consent or approval. Add Continuation Page

  6. 6

    Inadequate informed consent

    6. Legally effective informed consent was not obtained from a subject or the subject's legally authorized representative. Specifically, your general screening informed consent does not include a description of the specific procedures to be followed. You conducted mammograms, transvaginal ultrasounds, pap smears, and estradiol plasma concentrations on 48 enrolled subjects (plus extra subjects) prior to their study specific consent.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.