Equipment cleaning and cleaning validation in FDA Form 483 observations

Cleaning procedures for manufacturing equipment, the studies that show they work, and the residues, swabs and logs that prove each cleaning. FDAgent finds 197 such observations in 144 Form 483s issued to 138 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
197
Each quoted below
Form 483s
144
Posted by FDA
Facilities
138
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 63 in 2026

Equipment cleaning observations in Form 483s by inspection year
YearObservations
20081
20090
20100
20110
20120
20130
20141
20151
201610
201715
201820
20195
20205
202110
20227
202322
202413
202524
202663

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.6721 CFR 211.182

The same entries the equipment cleaning topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“cleaning validat*” · “validat* … cleaning” · “cleaning procedure*” · “cleaning process*” · “cleaning record*” · “cleaning log*” · “cleaning agent*” · “cleaning verification” · “cleaning stud*” · “cleaning method*” · “cleaning effectiveness” · “not cleaned” · “not adequately cleaned” · “not properly cleaned” · “residue*” · “swab*” · “carry over” · “carryover”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 197 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 4

    … Your firm has not performed cleaning validation studies to address microbiological and residue contamination for processes where such contamination could be of concern during manufacture of (b)(4) USP API. Equipment used in the manufacture of (b)(4) includes (b)(4). Cleaning procedures for equipment used to manufacture (b)(4) USP API for the U.S. market lack adequate detail and do not reflect actual practices. Your firm's cleaning procedures and …

    Contains “cleaning validat*”Read the Form 483 →

  2. Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 3

    … (b) (4) particulate matter consistent with (b) (4) was observed on the Grade (b) (4) floor, and localized areas accumulated significant (b) (4) residue. Batch (b) (4) of Myozyme was being filled when this observation was made. C) During the inspectional walkthrough on January 13, 2026, we observed a section in the Grade (b) (4) Filling Line (b) (4) (Room (b) (4)) where a portion of the (b) (4) had been removed. The floor in this area exhibited …

    Contains “residue*”Read the Form 483 →

  3. Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 4

    Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, A) On January 12, 2026, filling (b) (4) used for (b) (4) contained unknown brownish white residue around the (b) (4) Internal inspection revealed brownish red discoloration consistent with rust on product contact surfaces, which your firm …

    Opens with FDA's citation wording for 21 CFR 211.67(a)Read the Form 483 →

  4. Macau-Union Pharmaceutical LimitedInspection ended Dec 17, 2025 · FEI 3011219786 · Observation 6

    Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, Your firm has not validated your cleaning procedures and UV-Vis test method to demonstrate that cleaning of shared equipment is effective and reproducible at removing drug product residue and other contaminants that could adversely affect the quality of …

    Opens with FDA's citation wording for 21 CFR 211.67(b)Read the Form 483 →

  5. Dr. Reddy’s Laboratories LimitedInspection ended Dec 12, 2025 · FEI 3009193040 · Observation 3

    OBSERVATION 3 Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, you practice cleaning validation for equipment trains for the worst-case molecule. The (b)(4) cleaning validation for your Tablet Compression Machine ID # PR034 and (b)(4)(b)(4)(b)(4) ID # PR034 in was conducted in an equipment train for …

    Opens with FDA's citation wording for 21 CFR 211.67(b)Read the Form 483 →

  6. Wizcure Pharmaa Private LimitedInspection ended Dec 10, 2025 · FEI 3030304532 · Observation 2

    Equipment and utensils are not cleaned or maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. The following were observed throughout productions areas used to manufacture products for the US market. A. The (b)(4) Line consisting of rooms (b)(4) used to manufacture (b)(4) for the US market: 1. Apparent rusty equipment, apparent rusty components (b)(4), …

    Contains “not cleaned”Read the Form 483 →

  7. Huons Co., LtdInspection ended Nov 21, 2025 · FEI 3007163376 · Observation 6

    … You also have no study to monitor cleaning effectiveness. At the end of each batch production, only the (b)(4) glove is sampled per viable EM procedure. No fingers are monitored. You lacked justification for not monitoring gloves that are used during production and not sampling glove fingers.

    Contains “cleaning effectiveness”Read the Form 483 →

  8. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 5

    … Additionally, your firm failed to include the (b) (4) handles of the (b) (4) located in (b) (4) building in the surface monitoring program (swab sample). These (b) (4) are used by your operators and microbiologists to transfer settle plates, NVPC counter and volumetric air samplers from Grade C to Grade B areas. Not performing the surface monitoring in the (b) (4) handles represents a potential contamination risk during aseptic transfer. D. Your …

    Contains “swab*”Read the Form 483 →

  9. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 9

    Equipment and utensils are not cleaned, sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Your firm's cleaning and sanitization practice performed on filling line (b) (4) are inadequate to follow the cleaning and sanitization sequence from top to bottom of your filling line. For example, on November 04, 2025, your operators failed to follow a top to …

    Contains “not cleaned”Read the Form 483 →

  10. Implantica CE Reflux LimitedInspection ended Oct 24, 2025 · FEI 3015217460 · Observation 2

    … For example: A sample size of six was initially selected in Protocol (DT_DVP0007 01) Manual Cleaning Validation Plan on the suggestion as per ANSI/AAMI ST98: 2022 [9]. ANSI/AAMI ST98: 2022. This sample size was changed to 9, a more conservative sample size, as reflected in the validation report DT_DVR0007 03 Manual Cleaning Validation Report. Collectively, these validation reports did not adequately document the following: • the factors …

    Contains “cleaning validat*”Read the Form 483 →

  11. Hans Biomed CorporationInspection ended Sep 12, 2025 · FEI 3003828812 · Observation 1

    … Additionally, cleaning records for the (b) (4) and (b) (4) (referenced in Step (b) (4) and Step (b) (4) of other batch records) were reviewed and found to be inconsistent for the dates of use. For example: • The (b) (4) (Batch No. (b) (4), Donor ID (b) (4), (b) (6), (b) (7), Unprocessed Material No. (b) (4)) references (b) (4) Equipment No. (b) (4) and (b) (4) Cleaning Record No. (b) (4) in Step (b) (4), dated 04/21/25 (page 3). However, the …

    Contains “cleaning record*”Read the Form 483 →

  12. Creative Testing SolutionsInspection ended Aug 29, 2025 · FEI 3000204058 · Observation 1

    … Avioq HTLV-1/II In addition to utilizing (Db) (4), you are cleaning the (Db) (4) reagent reservoir using an unvalidated cleaning process that is required by the manufacturer to reuse the reservoir. Per your firm’s representatives, these reagent reservoirs are washed using (Db) (4) but no standard operating procedure has been established and no record of cleaning have been documented. From 07/15/2023 to present, you have performed (b) (4) …

    Contains “cleaning process*”Read the Form 483 →

  13. Hikma Injectables USA Inc.Inspection ended Aug 8, 2025 · FEI 3022897129 · Observation 2

    Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, On 07/29/2025, black discoloration was observed on the interior HEPA bracket of the Aseptic Processing Workstation. This was located within Room 121-B and was being utilized in the sterility testing of the following: Ketamine HCL …

    Opens with FDA's citation wording for 21 CFR 211.67(a)Read the Form 483 →

  14. Tripak Pharmaceuticals Pty Ltd.Inspection ended Jul 25, 2025 · FEI 3008549263 · Observation 8

    … According to the cleaning logbooks, these tanks had been cleaned; however, the status was not clearly indicated through proper labeling. According to your written procedure no. 30022.04: Status Labeling in Production, new green cleaned labels should be attached after equipment cleaning. The absence of clear status labeling creates potential for cross-contamination and makes it difficult to verify equipment readiness for use. These tanks are being …

    Contains “cleaning log*”Read the Form 483 →

  15. Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 2

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. Specifically, A. I observed apparent white colored residue and apparent brown or red colored stains on your work surfaces in your ISO 5 hood. The apparent white colored residue is also apparent throughout your ISO 5 environment affecting approximately all hoods. The design with the approximate of your working …

    Contains “residue*”Read the Form 483 →

  16. Guangxi Yulin Pharmaceutical Group Co. Ltd.Inspection ended Mar 21, 2025 · FEI 1000589993 · Observation 6

    Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality, or purity of the drug product. Specifically, Your firms cleaning validation studies to justify the cleaning in your (b) (4) preparation system are inadequate. For example, (A) You do not have records to show you have validated the cleaning procedures for extended clean hold times. (B) You failed to …

    Opens with FDA's citation wording for 21 CFR 211.67(a)Read the Form 483 →

  17. Nanjing Cuccess Pharmaceutical Co., LtdInspection ended Mar 21, 2025 · FEI 3027129265 · Observation 1

    Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically. A. Workshop 3 Room "Utensil Storage Room" contains cleaned equipment, utensils, and hoses storage. Examples of cleaning deficiencies observed in this room on March 20, 2025 include: 1.1 observed unknown residue inside all ports of …

    Opens with FDA's citation wording for 21 CFR 211.67(a)Read the Form 483 →

  18. Hangzhou Minsheng Binjiang Pharmaceutical Co., Ltd.Inspection ended Mar 7, 2025 · FEI 3007498452 · Observation 1

    Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, during the inspection, we observed residue (b) (4) in the (b) (4) duct of your (b) (4) (b) (4) (equipment ID # (b) (4)) which was labeled "cleaned". After analysis, your firm identified the residue to contain active pharmaceutical ingredient (b) (4). (b) (4) …

    Opens with FDA's citation wording for 21 CFR 211.67(a)Read the Form 483 →

  19. Hangzhou Minsheng Binjiang Pharmaceutical Co., Ltd.Inspection ended Mar 7, 2025 · FEI 3007498452 · Observation 2

    There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, your out-of-specification (OOS) investigation is not thorough and complete. For example, OOS investigation # 20240601 was initiated when (b) (4) residue tests yielded OOS results for three (3) batches (b) (4) Tablets: Batch # (b) (4) Result (specification: …

    Contains “residue*”Read the Form 483 →

  20. Emcure Pharmaceuticals LimitedInspection ended Feb 25, 2025 · FEI 3005782879 · Observation 1

    Failure to establish and follow adequate written procedures for cleaning and maintenance of equipment to prevent contamination or carryover of materials. Specifically, during a walkthrough of your facility on 19-20 February 2025, I observed multiple deficiencies related to equipment cleaning, cleaning validation, and maintenance, indicating a lack of adherence to established procedures. For example, but not limited to the following: A. …

    Contains “carryover”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about equipment cleaning in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.