Tripak Pharmaceuticals Pty Ltd
22 Neumann Rd, Capalaba, Australia
FEI 3008549263DUNS 758658819
FDA has one inspection on file for Tripak Pharmaceuticals Pty Ltd in Capalaba, Australia (FEI 3008549263). It ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and labeling, through Dec 31, 2026. Its registrant is Tripak Pharmaceuticals Pty Ltd (D-U-N-S 758658819).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2025
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest Jun 26, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
QC unit lacks authority, used failed components
The quality control unit lacks the responsibility and authority to approve, reject all drug products. Specifically, Your firm manufactured several products using inactive ingredients that failed testing. Following are the examples I observed during my review, but are not limited to: a) On 09/24/2024, your firm opened an OOS investigation #122 for one of the inactive ingredients used in the manufacturing of (b) (4) mL), Lot #(b) (4) (Bulk Lot #(b) (4) Exp (b) (4) Your contract testing laboratory reported twice for failed (b) (4) content in (b) (4), Batch (b) (4) Your firm proceeded with manufacturing of finished product Lot #(b) (4) using the failed inactive ingredient. This product was later released to your customer and subsequently shipped to the US market. b) On 05/16/2024, your firm opened an OOS investigation #115 for the inactive ingredient used in (b) (4) Lot #(b) (4) and (b) (4) Lot #(b) (4) Your contract testing laboratory reported an OOS for impurity failure in (b) (4) (b) (4) Lot #(b) (4) Related substances were reported as more than (b) (4)% for a specification of NMT (b) (4)%. Your firm proceeded with manufacturing of finished products Lot #(b) (4) and Lot #(b) (4) using the failed inactive ingredient. These products were later released to your customer and subsequently shipped to the US market.
- Observation 2
No specific ID tests for supplier-accepted components
Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis. Specifically, a) Your firm failed to conduct identification tests for raw materials used in drug product manufacturing. Specifically, your firm failed to verify the identity of each component prior to use in manufacturing operations. For example, your firm used (b) (4) (b) (4) Lot (b) (4) in the manufacture of (b) (4) (b) (4) Lot #(b) (4) Exp: (b) (4) without performing the required identification testing to confirm these materials met established specifications. The failure to conduct proper identification testing creates a significant risk that incorrect, adulterated, or substandard raw materials may be incorporated into finished drug products, potentially compromising product safety, efficacy, and quality. b) From 01/31/2024 to 02/07/2025, your firm released (b) (4) lots of (b) (4) (b) (4) to customer, and these lots were subsequently shipped to the US market. These lots were manufactured using (b) (4) as an inactive ingredient. Your firm failed to conduct specific identity analysis for each lot of (b) (4), which should include a limit test for (b) (4) and incorporate testing of samples from all containers of all lots received. Currently, your firm tests for (b) (4) (b) (4) which does not ensure the safety and quality of each individual lot used in manufacturing. For example, (b) (4), Lot #(b) (4) (Bulk Lot #(b) (4), Exp. (b) (4), was manufactured using (b) (4) Lot #(b) (4) which was accepted based solely on the supplier's Certificate of Analysis (COA) for (b) (4) (b) (4) without independent verification testing.
Show observations 3 to 9
- Observation 3
Inadequate production and process control procedures
Failure to establish adequate written procedures for production and process controls. Specifically, Your process validation report VMP-VR0031.00 for the manufacturing of (b) (4) bulk fails to demonstrate that written procedures designed to assure that drug products have the identity, strength, quality, and purity they purport or are represented to possess are adequate. The validation lacks sufficient details regarding critical process parameters, in-process controls, and acceptance criteria for manufacturing steps. Additionally, the validation scope is limited to bulk product testing and does not address process parameter controls to ensure consistent product quality throughout the manufacturing process. Moreover, your firm failed to validate the filling/packaging process.
- Observation 4
No finished product testing before release
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications, identity, and strength of each active ingredient prior to release. Specifically, Your firm failed to test finished drug products for all required specifications prior to release. From 05/04/2022 to 05/19/2025, your firm manufactured and released approximately (b) (4) batches to your customers without conducting comprehensive finished product testing. These lots were subsequently shipped to the US market. Your firm currently relies only on bulk drug testing results for finished product release, which is inadequate to ensure the quality and safety of the final dosage form. For example, the (b) (4) Lot #(b) (4) (Bulk Batch Lot #(b) (4) Exp: (b) (4) was released on 05/07/2024 without testing the finished dosage form, relying solely on bulk drug testing results. The absence of finished product testing creates significant risk that products not meeting quality standards may be released to the market, potentially compromising patient safety and product efficacy.
- Observation 5
No written stability testing program
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, Your firm failed to establish a written testing program designed to assess the stability characteristics of (b) (4) Your firm currently proposes a (b) (4) expiration period without adequate supporting stability data. The proposed expiration date is based solely on 6-month accelerated condition (ACC) data for bulk, which is insufficient to support the claimed shelf life according to established stability testing. Additionally, your firm failed to place at least one (1) batch of each commercial product on long-term stability testing under recommended storage conditions. This deficiency prevents your firm from demonstrating that the products maintain their identity, strength, quality, and purity throughout the proposed shelf-life period.
- Observation 6
No time limits or hold time studies
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product. Specifically, Your firm failed to conduct hold time studies for products manufactured at your facility. For example, on (b) (4), your firm compounded (b) (4), Bulk Lot #(b) (4), but did not complete filling operations until (b) (4) (final lot #(b) (4), representing a hold time of approximately (b) (4) between compounding and final packaging. Without proper hold time studies, your firm cannot demonstrate that the product maintains its identity, strength, quality, and purity during extended storage periods between manufacturing steps.
- Observation 7
Inadequate laboratory microbiological testing controls
Laboratory controls shall include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, drug product closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, From 05/04/2022 to 05/19/2025 your firm released approximately (b) (4) lots of products to customers without conducting (b) (4) testing. These lots shipped to the US market. All your products contains (b) (4) an inactive ingredient in the formulations, which significantly increases the microbiological risk profile and necessitates comprehensive microbiological testing to ensure product safety. For example, the (b) (4), Lot #(b) (4), Exp: (b) (4) was released on 05/07/2024 without conducting testing for (b) (4)
- Observation 8
Equipment lacking cleaning status labeling
Equipment and utensils shall be cleaned, maintained, and, as appropriate for the nature of the drug, sanitized and/or sterilized at appropriate intervals to prevent malfunctions or contamination that may alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements, Specifically, On 07/24/2025, during my walkthrough inspection at your manufacturing facility, I observed multiple (b) (4) tanks and transfer tanks without proper status labels. Specifically, I observed (b) (4) tanks in the warehouse and (b) (4) tanks in the compounding area that lacked appropriate status identification. According to the cleaning logbooks, these tanks had been cleaned; however, the status was not clearly indicated through proper labeling. According to your written procedure no. 30022.04: Status Labeling in Production, new green cleaned labels should be attached after equipment cleaning. The absence of clear status labeling creates potential for cross-contamination and makes it difficult to verify equipment readiness for use. These tanks are being used in the manufacturing of several products including The (b) (4) mL).
- Observation 9
Lack of strict control over labeling
Strict control shall be exercised over labeling issued for use in drug product labeling operations. Specifically, On 07/25/2025, during my walkthrough inspection, I observed inadequate label storage controls. Multiple different label rolls were stored together in plastic bags in an open warehouse environment accessible to all personnel, creating significant risk for label mix-ups, unauthorized access, and compromised chain of custody during labeling operations. Additionally, your firm failed to have a written procedure for the labeling issuance and control.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Jun 26, 2026. It asked for a Form 483.
Inspection ending Jul 25, 2025OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jun 26, 2026FDA-FOIA-2026-6138Form 483· 1 of 2 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling
- Registration runs through
- Dec 31, 2026
- Registrant
- Tripak Pharmaceuticals Pty LtdD-U-N-S 758658819
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3008549263 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3008549263. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.