Skip to content

Hangzhou Minsheng Binjiang Pharmaceutical Co., Ltd.

658 Bin'An Road, Binjiang District, Hangzhou, China

FEI 3007498452DUNS 547688780

FDA has 6 inspections on file for Hangzhou Minsheng Binjiang Pharmaceutical Co., Ltd. in Hangzhou, China (FEI 3007498452), from 2011 to 2025. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. Three FOIA requests have asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant is Hangzhou Minsheng Binjiang Pharmaceutical Co.,Ltd. (D-U-N-S 547688780).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
6, 2011–2025
1 OAI · 3 VAI · 2 NAI
Inspections with 483 observations shown
1 of 6
Form 483s posted by FDA
↗
Requested under FOIA
3 requests, latest Aug 1, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate equipment cleaning and validation

      Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, during the inspection, we observed residue (b) (4) in the (b) (4) duct of your (b) (4) (b) (4) (equipment ID # (b) (4)) which was labeled "cleaned". After analysis, your firm identified the residue to contain active pharmaceutical ingredient (b) (4). (b) (4) is non dedicated and is used to manufacture multiple drug products, including (b) (4) (b) (4) Tablets for the U.S. Additionally, your firm failed to assess the (b) (4) duct of your (b) (4) during your cleaning validation study.

    2. Observation 2

      Incomplete OOS investigation for residue failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, your out-of-specification (OOS) investigation is not thorough and complete. For example, OOS investigation # 20240601 was initiated when (b) (4) residue tests yielded OOS results for three (3) batches (b) (4) Tablets: Batch # (b) (4) Result (specification: NMT (b) (4) ppm) [illegible] The investigation determined that the most likely root cause was glove contamination caused by analyst error. This root cause was not adequately supported with evidence or data. Instead, (b) (4) fresh sample solutions were prepared for each affected batch for retesting. The retest yielded passing results, and the batches were released.

    Show observation 3
    1. Observation 3

      QC procedures not followed for GMP documents

      The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, during the inspection, we observed torn and discarded GMP documents in the trash bin located in the QC laboratory. Your firm was unaware that these GMP documents were altered and discarded. GMP documents are not managed according to your procedures, document # 02-QA-2-001 and 02-QA-2-004.

  2. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Aug 1, 2026. Each one asked for a Form 483.

  • Inspection ending Mar 7, 2025OAI

    3 requests. In the inspection history above. FDA has posted its Form 483.

    1. Aug 1, 2026FDA-FOIA-2026-8410Form 483Records released
    2. Jul 2, 2026FDA-FOIA-2026-6301Form 483· 1 of 3 sitesWithdrawn
    3. Jun 30, 2026FDA-FOIA-2026-6206Form 483· 1 of 2 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2026
Registrant
Hangzhou Minsheng Binjiang Pharmaceutical Co.,Ltd.D-U-N-S 547688780

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3007498452 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3007498452. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.