Hangzhou Minsheng Binjiang Pharmaceutical Co., Ltd. Form 483, March 2025
FDA issued this Form 483 to Hangzhou Minsheng Binjiang Pharmaceutical Co., Ltd. in Hangzhou, China (FEI 3007498452) at the end of a drug inspection that ended March 7, 2025. It lists 3 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 13, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Mar 7, 2025
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Nov 13, 2026
- 616 days after the inspection
The 3 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate equipment cleaning and validation
Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, during the inspection, we observed residue (b) (4) in the (b) (4) duct of your (b) (4) (b) (4) (equipment ID # (b) (4)) which was labeled "cleaned". After analysis, your firm identified the residue to contain active pharmaceutical ingredient (b) (4). (b) (4) is non dedicated and is used to manufacture multiple drug products, including (b) (4) (b) (4) Tablets for the U.S. Additionally, your firm failed to assess the (b) (4) duct of your (b) (4) during your cleaning validation study.
- 2
Incomplete OOS investigation for residue failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, your out-of-specification (OOS) investigation is not thorough and complete. For example, OOS investigation # 20240601 was initiated when (b) (4) residue tests yielded OOS results for three (3) batches (b) (4) Tablets: Batch # (b) (4) Result (specification: NMT (b) (4) ppm) [illegible] The investigation determined that the most likely root cause was glove contamination caused by analyst error. This root cause was not adequately supported with evidence or data. Instead, (b) (4) fresh sample solutions were prepared for each affected batch for retesting. The retest yielded passing results, and the batches were released.
- 3
QC procedures not followed for GMP documents
The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, during the inspection, we observed torn and discarded GMP documents in the trash bin located in the QC laboratory. Your firm was unaware that these GMP documents were altered and discarded. GMP documents are not managed according to your procedures, document # 02-QA-2-001 and 02-QA-2-004.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.