Skip to content

Macau-Union Pharmaceutical Limited

Rua Cinco Do Bairro Da Areia Preta S/N, Edf. Industrial Veng Fong 3-3a, Macao, Macao

FEI 3011219786DUNS 448605614

FDA has 2 inspections on file for Macau-Union Pharmaceutical Limited in Macao, Macao (FEI 3011219786), from 2016 to 2025. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below. Two FOIA requests have asked FDA for this inspection's 483.

FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is Macau-Union Pharmaceutical Limited (D-U-N-S 448605614).

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2016–2025
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest Apr 15, 2026
Import refusals
None under this FEI
Import alerts
66-40Red List
Matched on FDA’s firm name and street address
Drug establishment registration
Through

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      No finished product testing before release

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release. Specifically, a. Your firm does not perform any finished product testing (including but not limited to testing for contamination of objectionable microorganisms and assay) for drug products intended for the U.S. market other than checking for conformance to appearance and weight per unit specifications. There is no written documented agreement that testing and other GMP activities not performed by the firm is to be done by the customer, and that shipment is done so under quarantine. In 2025, your firm has manufactured and distributed (b)(4) the following drug products intended for the U.S. market: (b)(4) [illegible] aforementioned drug product batches includes the (b)(4) ml b. The finished product packaging of (b)(4) product packaging that bottle (with internal material code) (b)(4) sized, (b)(4) comes into direct contact with the drug product. Your firm does not subject this drug product container to microbiological tests before use as finished product (b)(4) packaging to ensure this drug product container does not introduce microbial contamination to the finished human drug products.

    2. Observation 2

      No identity testing of components

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist. Specifically, Your firm does not perform identity testing for components used to manufacture drug products intended for the U.S. market. Components without identity testing performed include but are not limited to: (b)(4) (b)(4) These components are the active pharmaceutical ingredients for (b)(4) drug products intended for the U.S. market.

    Show observations 3 to 8
    1. Observation 3

      Components not tested for quality specifications

      Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality. Specifically, Your firm does not test components used to manufacture drug products intended for the U.S. market for conformance to all appropriate specifications for quality. For example, your firm does not test the active pharmaceutical ingredients for (b)(4) (b)(4) to demonstrate conformance to all appropriate specifications for quality. (b)(4) Additionally, your firm relies on your suppliers' certificate of analysis results but has not appropriately established the reliability of these results. The suppliers' certificate of analysis show that components are not tested according to USP specifications. These test methods have not been demonstrated to be equivalent to or exceed USP standards.

    2. Observation 4

      Unvalidated manufacturing processes, no in-process testing

      Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Specifically, Your firm has not validated the production processes used to manufacture the over-the-counter finished human drug products intended for the U.S. market: (b)(4) (b)(4) Additionally, your firm does not conduct in-process testing during the production of these drug products intended for the U.S. market. For example, there is no in-process testing to assess factors such as microbiological contamination, inter- and intra-batch variability, and product uniformity. (b)(4) Your firm has manufactured and distributed (b)(4)

    3. Observation 5

      No stability testing program

      There is no written testing program designed to assess the stability characteristics of drug products. Specifically, Your firm does not perform stability testing for drug products intended for the U.S. market. There is no written documented agreement that stability testing is to be performed by the customer. Additionally, your firm does not have any data to demonstrate drug products intended for the U.S. market meet their established specifications throughout their labeled shelf-life of no longer than (b)(4) (b)(4) In 2025, your firm has manufactured and distributed (b)(4) the following drug products intended for the U.S. market: (b)(4)

    4. Observation 6

      Unvalidated cleaning of shared equipment

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, Your firm has not validated your cleaning procedures and UV-Vis test method to demonstrate that cleaning of shared equipment is effective and reproducible at removing drug product residue and other contaminants that could adversely affect the quality of drug products intended for the U.S. market. Additionally, shared equipment used to manufacture drug products intended for the U.S. market (b)(4) (b)(4) that has not been demonstrated to meet or exceed (b)(4) is cleaned using (b)(4) standards. appropriate (b)(4)

    5. Observation 7

      No annual reserve sample examinations

      Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration. Specifically, Your firm does not have procedures for performing an annual visual examination of reserve samples of over-the-counter human finished drug products, including drug products intended for the U.S. market, (b)(4) such as: (b)(4) Your firm also does not have records documenting the examination and results of an annual visual examination of reserve samples for evidence of deterioration throughout the storage of their intended shelf-life.

    6. Observation 8

      Batch records lack labeling specimens

      Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced. Specifically, Your firm did not include specimens or copies of all completed labeling, including the label adhered to packaging bottle and labeling on the (b)(4) packaging carton, in your batch production the (b)(4) records for packaging finished over-the-counter human drug products intended for the U.S. market. Your firm did not include specimens or copies of full labeling in each of the respective batch packaging (b)(4) records for the following finished drug products: (b)(4)

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Items to cover on annual reviews

      Written procedures are not established and followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.

    2. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.

    3. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.

    4. Lab controls established, including changes

      The establishment of test procedures and laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit.

    5. Examination of packaging and labeling

      Examination of packaging and labeling materials for suitability and correctness before packaging operations is not documented in the batch production records.

    Show 4 more citations
    1. Examination on receipt, before acceptance

      Each container or grouping of containers of drug product containers is not examined visually upon receipt and before acceptance for appropriate labeling as to contents, container damage and contamination.

    2. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not recorded and justified.

    4. Written procedures not followed

      Written procedures for the receipt, identification, sampling, examination and testing of packaging and labeling materials are not followed.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Apr 15, 2026. Each one asked for a Form 483.

  • Inspection ending Dec 17, 2025OAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Apr 15, 2026FDA-FOIA-2026-3788Form 483· 1 of 2 sitesRecords released
    2. Apr 1, 2026FDA-FOIA-2026-3260Form 483· 1 of 21 sitesClosed over fees

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 9 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.

Show all 9

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsAlert on fda.gov

    Date published 2026-03-24

    FDA’s entry
    Macau-Union Pharmaceutical Limited · Rua Cinco Do Bairro Da Areia Preta S/N, Edf. Industrial Veng Fong 3-3a, Macao, MACAO
    FDA’s inspection record for FEI 3011219786
    Macau-Union Pharmaceutical Limited · Rua Cinco Do Bairro Da Areia Preta S/N, Edf. Industrial Veng Fong 3-3a, Macao, Macao

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    15 products

    • 54 - D - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx 1 Ingr
    • 54 - E - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx Comb Ingr
    • 54 - F - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx 1 Ingr
    Show 12 more products
    • 54 - G - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx Comb Ingr
    • 54 - I - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Investigational
    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 56 - - - --Antibiotics (Human/Animal)
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2026
Registrant
Macau-Union Pharmaceutical LimitedD-U-N-S 448605614

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011219786 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011219786. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.