Equipment cleaning and cleaning validation in FDA Form 483 observations

Cleaning procedures for manufacturing equipment, the studies that show they work, and the residues, swabs and logs that prove each cleaning. FDAgent finds 197 such observations in 144 Form 483s issued to 138 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
197
Each quoted below
Form 483s
144
Posted by FDA
Facilities
138
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 63 in 2026

Equipment cleaning observations in Form 483s by inspection year
YearObservations
20081
20090
20100
20110
20120
20130
20141
20151
201610
201715
201820
20195
20205
202110
20227
202322
202413
202524
202663

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.6721 CFR 211.182

The same entries the equipment cleaning topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“cleaning validat*” · “validat* … cleaning” · “cleaning procedure*” · “cleaning process*” · “cleaning record*” · “cleaning log*” · “cleaning agent*” · “cleaning verification” · “cleaning stud*” · “cleaning method*” · “cleaning effectiveness” · “not cleaned” · “not adequately cleaned” · “not properly cleaned” · “residue*” · “swab*” · “carry over” · “carryover”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 197 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Shouguang Fukang Pharmaceutical Co., Ltd.Inspection ended Feb 21, 2025 · FEI 3003941038 · Observation 2

    Equipment is not cleaned or maintained at appropriate intervals to prevent contamination that would alter the quality or purity of the API product. A) Specifically, on 2/18/2025, inspection of the Workshop [illegible] where the API (b)(4) is manufactured noted excess residual product remaining on the bottom, upper wall, and shaft for the [illegible] Machine-[illegible] and [illegible] Machine-[illegible]. These units are used for [illegible] …

    Contains “not cleaned”Read the Form 483 →

  2. Shouguang Fukang Pharmaceutical Co., Ltd.Inspection ended Feb 21, 2025 · FEI 3003941038 · Observation 3

    … identified; for example, poor lighting conditions, raw materials were not identified or labeled, raw materials stored against walls, leaking [illegible], residues on concrete floor, and exterior door with large gaps for possible rodent/insect entry. B) Specifically, on 2/17/2025, inspection of the firm's finished API non-dedicated storage warehouse [illegible] noted the API [illegible] was being stored in random locations throughout this …

    Contains “residue*”Read the Form 483 →

  3. Piramal, Piramal Pharma LimitedInspection ended Feb 17, 2025 · FEI 3008763768 · Observation 4

    OBSERVATION 4 The cleaning of equipment is inadequate. Specifically, A. Cleaning procedures have not been validated for shared equipment used to manufacture and process crude APIs for the U.S. and other global markets. For example, the following shared equipment have not been evaluated as part of a cleaning validation program: 1. (b)(4) was used for (b)(4) step involving (b)(4) activity Date: December 31, 2024 to January 02, 2025, and December …

    Contains “cleaning procedure*”Read the Form 483 →

  4. Glenmark Pharmaceuticals Ltd.Inspection ended Feb 14, 2025 · FEI 3008565058 · Observation 1

    Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, you failed to implement adequate contamination control procedures to ensure drug products manufactured at your site using non-dedicated equipment are not cross-contaminated by residues from the (b><. A. Since (b)(TC, there were approximately [illegible] after …

    Opens with FDA's citation wording for 21 CFR 211.67(a)Read the Form 483 →

  5. Glenmark Pharmaceuticals Ltd.Inspection ended Feb 14, 2025 · FEI 3008565058 · Observation 2

    … dispensing mg products, you use these areas to sample & dispense (b)(4) mg products without any verification by [illegible] equipment, and air is free from residues (CbTT4l. 2. Areas, major production [illegible] used for other routine (liJ1 a [illegible] of [illegible] mg products; you use these areas for mg products without a verification by appropriate testing that these areas and air is free from residues of other products. 3. c;· packing …

    Contains “residue*”Read the Form 483 →

  6. Zhejiang Huahai Pharmaceutical Co., Ltd.Inspection ended Jan 24, 2025 · FEI 3003999190 · Observation 1

    OBSERVATION #1 Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product 1. Cleaning of non-dedicated used to manufacture US market products was not effective. There are on-dedicated.._______l---,-,-""""'market product,;. The following was observed on cleaned equipment: ----.(bT(4 Prior to batcl__....,...,...._the equipment had …

    Opens with FDA's citation wording for 21 CFR 211.67(a)Read the Form 483 →

  7. Zhejiang Huahai Pharmaceutical Co., Ltd.Inspection ended Jan 24, 2025 · FEI 3003999190 · Observation 4

    … The area was cleaned without any analytical evaluation of the observed residues and no pictures were taken. The investigation did not thoroughly assess whether contamination in this area could have impacted other batches made on this equipment. Additional batches made as part of the same campaign were not thoroughly inspected for the presence of foreign particles. (1' The investigation was not expanded to inspect the ucts and document findings in …

    Contains “residue*”Read the Form 483 →

  8. Hankook Cosmetics Manufacturing Co., LtdInspection ended Nov 21, 2024 · FEI 3012656014 · Observation 5

    Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, A. Ancillary containers used for the dispensing of raw materials for manufacturing are not maintained in a clean state. For example, during the walkthrough of the drying room for ancillary containers on 18Nov2024, I observed containers which …

    Opens with FDA's citation wording for 21 CFR 211.67(b)Read the Form 483 →

  9. Lights Medical Manufacture Co., LtdInspection ended Nov 8, 2024 · FEI 3005310494 · Observation 2

    Written records of major equipment use are not included in individual equipment logs. Specifically, Your firm does not maintain equipment use logs for equipment used in the manufacturing process of over-the-counter drug products. This includes, but is not limited to, the following equipment: Name of Manufacturing Equipment Equipment ID(s) [illegible]

    Opens with FDA's citation wording for 21 CFR 211.182Read the Form 483 →

  10. Staska Pharmaceuticals IncInspection ended Sep 18, 2024 · FEI 3017473850 · Observation 5

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, A. Your firm has not conducted a cleaning validation on product contact equipment including stainless steel mixing pots and mixing impellers to assure your cleaning process removes microbial content or chemical residues on the equipment used in your aseptic operations. (b) (4) stainless …

    Contains “cleaning validat*”Read the Form 483 →

  11. Staska Pharmaceuticals IncInspection ended Sep 18, 2024 · FEI 3017473850 · Observation 7

    … The (b) (4) is used for cleaning validation conducted from 12/7/2021 through 1/20/2022 as well as routine environmental and personnel monitoring in the ISO 5 and ISO 7 manufacturing rooms. To date, no gram negative bacteria or yeast have been recovered at this facility and there is no growth promotion data showing that agar used at this facility can recover either gram negative bacteria or yeast. D. ISO-5 classified areas were not adequately …

    Contains “cleaning validat*”Read the Form 483 →

  12. Rechon Life Science ABInspection ended Sep 6, 2024 · FEI 3002806978 · Observation 2

    … titled "Identification of critical monitoring locations for viable and non-viable particles on the ampoule filling line", approved on 04/02/2024, no swab or contact surface samples are collected from the referenced areas. C. We observed a manufacturing operator performing the intervention identify as (b) (4) (b) (4) This (b) (4) is located at the back of the ampoule line within the aseptic core. During this set-up intervention, we observed the …

    Contains “swab*”Read the Form 483 →

  13. Huangshi Hygenic Material Medicine Co.Inspection ended Aug 30, 2024 · FEI 3005543486 · Observation 2

    Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, Equipment and utensils used for the manufacture of US drug products are not cleaned and maintained to prevent contamination including the following A) (b) (4) S02009 used for the formulation of drug product (b) (4) B) (b) (4) S02008 used for …

    Opens with FDA's citation wording for 21 CFR 211.67(a)Read the Form 483 →

  14. Huangshi Hygenic Material Medicine Co.Inspection ended Aug 30, 2024 · FEI 3005543486 · Observation 5

    … C) Your firm has not designed and performed cleaning validation studies on equipment used in the manufacture of US drug products including for (b) (4) D) You do not follow your procedure for "(b) (4) operating Regulations" CZ-21-4114 for testing of (b) (4) The procedure requires (b) (4) testing of (b) (4) including for microorganisms. Your last (b) (4) testing was performed on (b) (4) The (b) (4) is used in the production of US drug products and …

    Contains “cleaning validat*”Read the Form 483 →

  15. Global Calcium Private LimitedInspection ended Aug 2, 2024 · FEI 3004094136 · Observation 1

    Production records do not contain complete information relating to the production and control of each batch. The Production Head stated that he directed employees to create batch records and supporting records including cleaning records and equipment use logs for activities that did not actually occur in Plant [®®Plant®®is intended to be used for the manufacturing of the US market product ©9 Injection Grade APL The Plant ®®Manager stated he used …

    Contains “cleaning record*”Read the Form 483 →

  16. Global Calcium Private LimitedInspection ended Aug 2, 2024 · FEI 3004094136 · Observation 2

    Procedures for issuance and controls of documents are not followed. 1. QA issues duplicate equipment use logs and cleaning logs with the same issuance number. These duplicate logs are used in creation of records that document activities that did not occur. QA subsequently reviews and approves both sets of contradictory records. 2. The QC laboratory keeps uncontrolled notebooks which contain measurements associated with assay, LOD, pH, …

    Contains “cleaning log*”Read the Form 483 →

  17. Divi's Laboratories Ltd. (Unit II)Inspection ended Jul 19, 2024 · FEI 3004149463 · Observation 1

    Written procedures are not established for the cleaning of equipment used in the manufacture of (b)(4) API. Specifically, SOP "CLEANING PROCEDURES", SOP NO: PD/OP/0017, REV NO: 000, EFFECTIVE DATE: 01/01/2021, does not include provisions to clean or visually inspect the area (b)(4) (b)(4) (b)(4) behind the (b)(4) of (b)(4) are used in the manufacture of (b)(4)

    Contains “cleaning procedure*”Read the Form 483 →

  18. MSN Laboratories Private Limited, Unit-IIInspection ended Mar 22, 2024 · FEI 3008656542 · Observation 1

    Your firm failed to properly maintain buildings and facilities used in the manufacture of API in a clean condition. Specifically, during a walkthrough of your facility on March 18, 2024, I observed what appeared to be water staining and unknown residue on ceiling tiles located above retain samples, as well as on the baseboard behind the retains, in your API Reserve Sample Storage Room. Examples of retain samples stored in the API Reserve Sample …

    Contains “residue*”Read the Form 483 →

  19. Fukuzyu Pharmaceutical Co., Ltd.Inspection ended Jan 19, 2024 · FEI 3002807025 · Observation 2

    Shared production equipment is not always cleaned and maintained in a manner suitable to prevent cross contamination of non-hazardous API by hazardous substances. Specifically, On 01/16/2023, I observed apparent residue and particulates inside the L__ housing of S-7 and the product (b)(4) (b)(4). The [illegible] equipment was estimated clean after cleaning verification with rinse samples, swab samples, and visual inspection was complete. These …

    Contains “residue*”Read the Form 483 →

  20. Jiangsu Hengrui Pharmceuticals Co., LtdInspection ended Jan 16, 2024 · FEI 3007373503 · Observation 3

    Equipment and utensils are not cleaned appropriately to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, Your cleaning validation studies for [illegible] cleaning of multi-use filling equipment, cleaning of vials, stoppers and (b)(4) for (b)(4) are inadequate. A) Worst-case contaminants (hardest to clean products) determinations did not take into consideration the …

    Contains “not cleaned”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about equipment cleaning in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.