Hankook Cosmetics Manufacturing Co., Ltd
74 Daeseongro547beon-Gil, Samseong-Myeon, Eumseong, Korea (the Republic of)
FEI 3012656014DUNS 688235645
FDA has 2 inspections on file for Hankook Cosmetics Manufacturing Co., Ltd in Eumseong, Korea (the Republic of) (FEI 3012656014), from 2019 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. One of the three FOIA requests for this site has asked FDA for this inspection's 483.
6 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant is Hankook Cosmetics Manufacturing Co.,Ltd_Eumseong Factory (D-U-N-S 688235645).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2019–2024
- 0 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 1 of 2
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 3 requests, latest Jun 1, 2026
- Warning letters
- None on file
- Import refusals
- 6 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Stability testing not used for expiration dates
Results of stability testing are not used in determining expiration dates. Specifically, Procedure QP-20-17, "Stability Test" requires long term stability studies for establishment and confirmation expiration date applied to OTC drug products. [illegible] drug product lots had stability (b)(4) [illegible] studies initiated between 2018 and 2019, however all of these studies were cancelled approximately three months after the stability studies were initiated. To date, there has been no stability studies completed to confirm the (b)(4) expiration date established for any drug products manufactured at the firm. In addition, according to the reporting worksheets for drug products, informal results were recorded for 9-month and 12-month timepoints for attributes such as pH and viscosity in which several lots did not meet the established criteria. There was no investigation conducted to determine the impact of these out of specification results on those drug products which had been distributed to the US market. [illegible] unique drug products were manufactured in the year 2019, however only 4 of these drug products were placed on stability.
- Observation 2
Incomplete laboratory testing records documentation
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. Specifically, Records related to chemical and microbiological testing do not include all the information related to the execution of the test. For example, (b)(4) is tested for (b)(4) and microbial limits. The laboratory records do not include complete information related to the execution of the tests, including but not limited to the following: 1. The standards used for the (b)(4) analysis are prepared using (b)(4). There is no documentation to support the standard solution preparation, including the lot of standard used, the pipets used, and the reagent used to perform the (b)(4). Furthermore, there is no defined procedure for conducting the (b)(4) analysis on (b)(4). 2. The microbial limits test is conducted following QR084, which requires (b)(4) be (b)(4) of (b)(4). The documentation for (b)(4) directly added to a Plate Count (b)(4) and incubated for (b)(4) at (b)(4) testing is inadequate in that there is no record of the lot number of the plates being used for the test, the incubator ID where the plates were stored, and the times in which the plates were placed and removed for incubation. In addition, no growth promotion is conducted for any incoming lots of plate. Furthermore, the plate counts recorded after each pull do not have a signature and date of count (b)(4) who performed the reading and when, each reading does not have a secondary review until (b)(4) and there is no documentation of the environment, including the use of a plate reader or (b)(4) ambient lighting, for reading of the plates. Furthermore, additional worksheets used for documenting analyses and results, including for assay testing in finished products, does not document complete data related to testing, including but not limited to, instrument parameters, column usage, reference standard and reagent usage, and reference standard and sample preparation information, when applicable.
Show observations 3 to 5
- Observation 3
Quality control unit procedures not written followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A. There are no written procedures which outline the process for verification by the Quality Unit of the paper and electronic analytical data to ensure that the data and the calculated test results are complete and accurate for all chemical and microbial tests performed. B. There is no written procedure which outlines the issuance, use, and reconciliation of logbooks and worksheets used within the manufacturing area (including, but not limited to batch production records for bulk manufacturing, filling, and packaging and labeling, and equipment logbooks), and the laboratory (including but not limited to analytical raw data worksheets, equipment usage logs, reference standard logs used for documenting weight, and laboratory inventory logs). C. According to QP-20-18, Product Review", product reviews are required to be (b)(4). Product reviews [illegible] drug products manufactured within [illegible] were not conducted for the approximately (b)(4) (b)(4) as required per procedure.
- Observation 4
Sampling plans not followed and documented
Established sampling plans are not followed and documented at the time of performance. Specifically, Sampling of the (b)(4) system is not adequately documented, established, or justified. For example: 1. According to QP-14-02, Test Management", prior to sampling the point of use, the (b)(4) (b)(4). There is no specific time requirement that the point of use must be (b)(4) [illegible] analyst prior to collecting the sample, nor is the amount of time the point of use is [illegible] documented. 2. Sampling is conducted on (b)(4) points of use within the facility (b)(4) according to QP-14-02, "(b)(4) Test Management". However, (b)(4) points of use are within the facility. To date, there has been no samples additional or data collected to confirm that the [illegible] meets the established (b)(4) (b)(4) specifications.
- Observation 5
Equipment cleaning procedures not established followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, A. Ancillary containers used for the dispensing of raw materials for manufacturing are not maintained in a clean state. For example, during the walkthrough of the drying room for ancillary containers on 18Nov2024, I observed containers which contained various amounts of water remaining at the bottom of the equipment, including containers that had already been labeled as fully cleaned. B. The preparation of the detergent used for the cleaning of manufacturing and ancillary equipment used in manufacturing is not adequately documented. Your quality personnel described that the detergent (b)(4). This preparation used for cleaning is prepared by [illegible] is not described in any procedure, nor is the preparation documented, including lot number of detergent used and expiration date of the prepared solution. C. After completion of manufacturing operations, according to QP-14-01, (b)(4) Management", the (b)(4) remaining in the (b)(4) tank is to be returned to the main holding tank, and the (b)(4) tank is to be sanitized with the (b)(4). There is no documentation that supports this operation is conducted. D. According to QP-14-01, "(b)(4) Management", the sanitization performed [illegible] storage tank requires the use of the (b)(4) tank. There is no [illegible] the (b)(4) is used for this cleaning nor is there any verification that the (b)(4) is fully removed from the tank prior to resuming cleaning and manufacturing operations.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Jun 1, 2026. Each one asked for a Form 483.
Inspection ending Nov 21, 2024VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Mar 12, 2026FDA-FOIA-2026-2406Form 483 + EIR· 1 of 9 sitesRecords released
Inspection date not given
2 requests. FDA released records in answer to a request for its Form 483 + EIR on Apr 23, 2026. FDAgent holds no copy that FDA posted.
- Jun 1, 2026FDA-FOIA-2026-5440Form 483 + EIR· 1 of 2 sitesRecords released
- Apr 13, 2026FDA-FOIA-2026-3653Form 483 + EIR· 1 of 3 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3012656014, one row per refused product line.
6 refusals from 2019-08-16 to 2025-04-10 · charged INCONSPICU on 3, NOT LISTED on 2 · no FDA sample analysis
FDA firm profile- 2025-04-10
MISCELLANEOUS PATENT MEDICINES, ETC.66VAY99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-6983806-0/11/1
- 2024-08-16
ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBJ99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-2582842-9/11/4
- 2024-08-16
ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast Imports799-2553969-5/31/1
- 2019-08-30
ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBJ99
INCONSPICU 502(c), 801(a)(3); MISBRANDING
Division of West Coast Imports231-0054326-9/21/2
- 2019-08-30
ZINC OXIDE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBL18
INCONSPICU 502(c), 801(a)(3); MISBRANDING
Division of West Coast Imports231-0054326-9/21/1
Show 1 more
- 2019-08-16
ZINC OXIDE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBL18
NOT LISTED 502(o), 801(a)(3); MISBRANDING
INCONSPICU 502(c), 801(a)(3); MISBRANDING
Division of West Coast Imports231-0055025-6/21/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- Hankook Cosmetics Manufacturing Co.,Ltd_Eumseong FactoryD-U-N-S 688235645
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012656014 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012656014. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.