Hankook Cosmetics Manufacturing Co., Ltd Form 483, November 2024
FDA issued this Form 483 to Hankook Cosmetics Manufacturing Co., Ltd in Eumseong, Korea (the Republic of) (FEI 3012656014) at the end of a drug inspection that ended November 21, 2024. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Oct 20, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Nov 21, 2024
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Oct 20, 2026
- 698 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Stability testing not used for expiration dates
Results of stability testing are not used in determining expiration dates. Specifically, Procedure QP-20-17, "Stability Test" requires long term stability studies for establishment and confirmation expiration date applied to OTC drug products. [illegible] drug product lots had stability (b)(4) [illegible] studies initiated between 2018 and 2019, however all of these studies were cancelled approximately three months after the stability studies were initiated. To date, there has been no stability studies completed to confirm the (b)(4) expiration date established for any drug products manufactured at the firm. In addition, according to the reporting worksheets for drug products, informal results were recorded for 9-month and 12-month timepoints for attributes such as pH and viscosity in which several lots did not meet the established criteria. There was no investigation conducted to determine the impact of these out of specification results on those drug products which had been distributed to the US market. [illegible] unique drug products were manufactured in the year 2019, however only 4 of these drug products were placed on stability.
- 2
Incomplete laboratory testing records documentation
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. Specifically, Records related to chemical and microbiological testing do not include all the information related to the execution of the test. For example, (b)(4) is tested for (b)(4) and microbial limits. The laboratory records do not include complete information related to the execution of the tests, including but not limited to the following: 1. The standards used for the (b)(4) analysis are prepared using (b)(4). There is no documentation to support the standard solution preparation, including the lot of standard used, the pipets used, and the reagent used to perform the (b)(4). Furthermore, there is no defined procedure for conducting the (b)(4) analysis on (b)(4). 2. The microbial limits test is conducted following QR084, which requires (b)(4) be (b)(4) of (b)(4). The documentation for (b)(4) directly added to a Plate Count (b)(4) and incubated for (b)(4) at (b)(4) testing is inadequate in that there is no record of the lot number of the plates being used for the test, the incubator ID where the plates were stored, and the times in which the plates were placed and removed for incubation. In addition, no growth promotion is conducted for any incoming lots of plate. Furthermore, the plate counts recorded after each pull do not have a signature and date of count (b)(4) who performed the reading and when, each reading does not have a secondary review until (b)(4) and there is no documentation of the environment, including the use of a plate reader or (b)(4) ambient lighting, for reading of the plates. Furthermore, additional worksheets used for documenting analyses and results, including for assay testing in finished products, does not document complete data related to testing, including but not limited to, instrument parameters, column usage, reference standard and reagent usage, and reference standard and sample preparation information, when applicable.
- 3
Quality control unit procedures not written followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A. There are no written procedures which outline the process for verification by the Quality Unit of the paper and electronic analytical data to ensure that the data and the calculated test results are complete and accurate for all chemical and microbial tests performed. B. There is no written procedure which outlines the issuance, use, and reconciliation of logbooks and worksheets used within the manufacturing area (including, but not limited to batch production records for bulk manufacturing, filling, and packaging and labeling, and equipment logbooks), and the laboratory (including but not limited to analytical raw data worksheets, equipment usage logs, reference standard logs used for documenting weight, and laboratory inventory logs). C. According to QP-20-18, Product Review", product reviews are required to be (b)(4). Product reviews [illegible] drug products manufactured within [illegible] were not conducted for the approximately (b)(4) (b)(4) as required per procedure.
- 4
Sampling plans not followed and documented
Established sampling plans are not followed and documented at the time of performance. Specifically, Sampling of the (b)(4) system is not adequately documented, established, or justified. For example: 1. According to QP-14-02, Test Management", prior to sampling the point of use, the (b)(4) (b)(4). There is no specific time requirement that the point of use must be (b)(4) [illegible] analyst prior to collecting the sample, nor is the amount of time the point of use is [illegible] documented. 2. Sampling is conducted on (b)(4) points of use within the facility (b)(4) according to QP-14-02, "(b)(4) Test Management". However, (b)(4) points of use are within the facility. To date, there has been no samples additional or data collected to confirm that the [illegible] meets the established (b)(4) (b)(4) specifications.
- 5
Equipment cleaning procedures not established followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, A. Ancillary containers used for the dispensing of raw materials for manufacturing are not maintained in a clean state. For example, during the walkthrough of the drying room for ancillary containers on 18Nov2024, I observed containers which contained various amounts of water remaining at the bottom of the equipment, including containers that had already been labeled as fully cleaned. B. The preparation of the detergent used for the cleaning of manufacturing and ancillary equipment used in manufacturing is not adequately documented. Your quality personnel described that the detergent (b)(4). This preparation used for cleaning is prepared by [illegible] is not described in any procedure, nor is the preparation documented, including lot number of detergent used and expiration date of the prepared solution. C. After completion of manufacturing operations, according to QP-14-01, (b)(4) Management", the (b)(4) remaining in the (b)(4) tank is to be returned to the main holding tank, and the (b)(4) tank is to be sanitized with the (b)(4). There is no documentation that supports this operation is conducted. D. According to QP-14-01, "(b)(4) Management", the sanitization performed [illegible] storage tank requires the use of the (b)(4) tank. There is no [illegible] the (b)(4) is used for this cleaning nor is there any verification that the (b)(4) is fully removed from the tank prior to resuming cleaning and manufacturing operations.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.