Staska Pharmaceuticals Inc Form 483, September 2024
FDA issued this Form 483 to Staska Pharmaceuticals Inc in Bennet, Nebraska (FEI 3017473850) at the end of a drug inspection that ended September 18, 2024. It lists 9 observations. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on May 5, 2025.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 5, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Sep 18, 2024
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Nov 5, 2024
- 48 days after the inspection
The 9 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Failure to thoroughly investigate batch discrepancies
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, During your firm's visual inspection of Buffered Lidocaine HCl USP 2% 20mg/mL, 50mL Vials for injection Lot (b) (4) MFG 08/30/2022, (b) (4) vials were rejected due to defects including particles, package defects, sealing defects and abnormal fill volume. Deviation DR/PD/22/09/004 determined the root cause for the defects was contamination and damage incurred during transportation. However, the investigation wasn't expanded to determine if other lots using Lot (b) (4) were affected. CAPAs included (b) (4) vials to prevent rattling and post-cleaning inspections by the vial manufacturer. The batch was rejected but no CAPA's were implemented by your firm, and no effectiveness check was conducted. A second deviation occurred on July 19, 2024. During your firm's visual inspection of Ascorbic Acid 500mg/mL 50mL Vials for sterile injection Lot (b) (4), BUD 12/31/2024, you initially identified (b) (4) vials containing glass particles. As a result, deviation DR/PD/24/07/006 was initiated. After testing Amber Vials Lot (b) (4) the root cause was identified as glass contamination. However, the other (b) (4) amber vial lots used in filling batch (b) (4) were not tested and the investigation was not expanded to determine if Lots (b) (4), (b) (4) were affected. CAPAs included implementing an in-house testing procedure to test for particles prior to approval of the vials. No effectiveness check was conducted. The testing procedure has been implemented practically but the SOP remains in the draft phase. Additionally, since there are no established limits or rejection rates for defects identified during the visual inspection process, (b) (4) vials of Ascorbic Acid 500mg/mL 50mL Vials for injection Lot (b) (4), BUD 12/31/2024 were released and distributed.
- 2
No visual inspection acceptance criteria established
Your firm failed to establish acceptance criteria for the sampling and testing conducted by the quality control unit that are adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release. Specifically, In regards to your 100% visual inspection of finished product vials and syringes: Your firm has not implemented a clear classification scheme for defects, including critical, major, and minor categories nor have you established rejection rates to identify atypical lots. Furthermore, there is no SOP for this process.
- 3
Inadequate visual inspector training program
Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions. Specifically, A. Your firm has not implemented a clear classification scheme for defects, including critical, major, and minor categories. In addition, there is an absence of established, documented defect characterizations that detail defect size ranges, specific defect locations on containers, and where feasible, photographs of the defects to ensure consistency in defect identification during qualification visual inspections. B. Your firm has not incorporated defect types routinely encountered during production into the training program. The absence of naturally occurring defects or production rejects in inspector training can limit an inspector's ability to detect actual production-related defects effectively during routine inspections. C. Your firm has not established a limit for false rejection of acceptable vials during a visual inspection qualification. D. There is no requirement to conduct a 360-degree visual inspection of each unit. Full rotation (360°) of the container during the container-closure defect inspection sequence is recommended for identifying small container defects such as cracks or chips.
- 4
Deficient aseptic environmental monitoring system
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, According to SOP MC010, Environmental Monitoring, Rev 06, microbial contamination recovery limits for the elbows or gowning elements of operators are set at Alert: NA and Action: (b) (4), while the limit for hands or gloves entering the Grade A area is Action (b) (4) However, when operators conduct interventions in which they open the (b) (4) door, both their elbows and hands/gloves enter the ISO 5 area. During the filling of (b) (4), Buffered Lidocaine 1%, production technicians were observed reaching into the ISO 5 laminar flow hood past their elbows to clean the hangers for the suspension rod and placement of the settle plate. Additionally, viable air monitoring was conducted during the calibration of the repeater pump and not during routine filling.
- 5
Deficient cleaning and disinfection of aseptic areas
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, A. Your firm has not conducted a cleaning validation on product contact equipment including stainless steel mixing pots and mixing impellers to assure your cleaning process removes microbial content or chemical residues on the equipment used in your aseptic operations. (b) (4) stainless steel pots were used in batches including but not limited to: Methylcobalamin 1 mg/mL 30 mL Preserved Lot (b) (4), Methylcobalamin 5 mg/mL 30 mL Preserved Lot (b) (4), Buffered Lidocaine HCL 1% (10 mg/mL) Syringes Lot (b) (4), Buffered Lidocaine HCL 1% (10 mg/mL) Syringes Lot (b) (4). B. The wet contact times specified in SOP PD016 Cleaning, Disinfection of ISO 5, ISO 7, ISO 8 Areas and Equipment, Rev 5 for cleaners and disinfectants are not consistently being met. During cleaning and disinfection of Room (b) (4) (ISO 8) on 09/09/2024, Room (b) (4) (ISO 7) on 09/09/2024 and left laminar flow hood (ISO 5) on 09/09/2024, the established (b) (4) wet contact time for (b) (4) was not met.
- 6
No production and process control procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, A. Your firm has not performed Process Validation (PV) for finished products. You have considered performance of stability studies suitable to satisfy PV requirements. There are no documented / established written PV protocols or reports. From 2021 until the beginning of this inspection, the firm has made (b) (4) batches of products including but not limited to: Product Batches Ascorbic Acid 500 mg/mL 10 mL Syringes (b) (4), Ascorbic Acid 500 mg/mL 50 mL vial, Ascorbic Acid 500 mg/mL 50 mL vial Preserved, B Complex, Buffered Lidocaine HCL 1% (10mg/mL) 10 ml syringe, Buffered Lidocaine HCL 2% (20 mg/mL) 50 mL, Buffered Lidocaine HCL 2% (20 mg/mL) Syringes, Glutathione injection (200 mg/mL), Glutathione injection (200 mg/mL) 30 mL Preserved, Methyl Cobalamin 5 mg/mL 30 mL preserved, Methylcobalamin 1 mg/mL Preserved 30 mL vial, Methylcobalamin 25 mg/mL Preserved. B. An unapproved ingredient, (b) (4) that was not part of the approved formulation, batch record, or product label was added to the following batches: Batch (b) (4), Ascorbic Acid Preserved BUD: 07/07/2023, Batch (b) (4) Methylcobalamin 25 mg/mL BUD: 10/21/2023, Batch (b) (4) Methylcobalamin 25 mg/mL BUD: 06/30/2024. C. Hold times for in-process bulk material have not been established or validated. For example: Batch (b) (4) Ascorbic Acid Preserved BUD: 05/24/2024 - bulk solution was covered and held for (b) (4) due to a "stuck syringe" on the (b) (4) filling line. Batch (b) (4) Ascorbic Acid Preserved BUD: 08/02/2024 - bulk solution was covered and held for (b) (4) due to a "stuck syringe" on the (b) (4) filling line.
- 7
Sterile contamination prevention procedures not established
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established or followed. Specifically, A. Your aseptic personnel practices and interventions are not scientifically justified or documented. 1. Corrective and inherent interventions are not documented in your batch record. 2. You do not document the amount of time each operator participates in or the activities they perform as part of the media fill for the (b) (4) fill line. 3. Interventions performed during media fills do not reflect routine production. B. Media fills do not document: 1. Aseptic assembly of equipment (e.g., at start-up, during processing) 2. Time personnel participate and their activities 3. Representative number of aseptic additions (e.g., charging containers and closures as well as sterile vials) or transfers 4. Raw data results of all media vials incubated (results for unknown number of vials or vials associated with interventions only) C. Growth promotion is not conducted on every lot of (b) (4) received and data loggers are not used to document the conditions of shipping. SOP MC015, Growth Promotion Test of Microbiological Media Effective 1/13/2022 does not require growth promotion to be performed on each batch of purchased (b) (4) received. The (b) (4) is used for cleaning validation conducted from 12/7/2021 through 1/20/2022 as well as routine environmental and personnel monitoring in the ISO 5 and ISO 7 manufacturing rooms. To date, no gram negative bacteria or yeast have been recovered at this facility and there is no growth promotion data showing that agar used at this facility can recover either gram negative bacteria or yeast. D. ISO-5 classified areas were not adequately certified under dynamic conditions. For example: 1. The smoke study labeled ISO5 Syringes fails to incorporate all aseptic operations used in routine production that can potentially disrupt unidirectional airflow within the ISO5 laminar flow hood. 2. Smoke study ISO5 Syringes and ISO5 (b) (4) were not informative as the generated "smoke" was not robust, widespread or continuous to demonstrate airflow on your (b) (4) line or in ISO 5 laminar flow hood. 3. Your smoke study, ISO5 Syringes shows an influx of poor quality air from ISO7 Room (b) (4) into the ISO5 laminar flow hood.
- 8
Container labels missing required 503B information
The containers of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(B). Specifically, your containers do not include the following information: a. Information to facilitate adverse event reporting: www.fda.gov/medwatch and 1-800-FDA-1088; Examples of your container labels that do not contain this information: Ascorbic Acid Inj. Solution (Preserved, Non-corn) 25,000mg/50mL (500mg/mL), (b) (4) Solution, Glutathione Inj. Solution (Preservative free) 2,000mg/10mL (200mg/mL), Lidocaine 2% Buffered Inj. Solution (PF) 1000mg/50mL (20mg/mL). b. Directions for use, including, as appropriate, dosage and administration. Examples of your container labels that do not contain this information include: Ascorbic Acid Inj. Solution (Preserved, Non-corn) 25,000mg/50mL (500mg/mL), Lidocaine 2% Buffered Inj. Solution (PF) 1000mg/50mL (20mg/mL).
- 9
Bulk substance from unregistered establishment
Bulk drug substances used by your outsourcing facility to compound drug products are not manufactured by an establishment that is registered under section 510 as required by section 503B(a)(2)(C). Specifically, The bulk drug substance, (b) (4) is manufactured by, (b) (4)., an establishment that is no longer registered under section 510 as required by section 503B(a)(2)(C).
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterMay 5, 2025Staska Pharmaceuticals, Inc. warning letter, May 5, 2025CDER · 229 days after this inspection ended
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3017473850, newest first.
- Form 483, February 2026Inspection ended Feb 20, 2026 · Posted May 8, 2026OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.