Skip to content

Global Calcium Private Limited Form 483, August 2024

FDA issued this Form 483 to Global Calcium Private Limited in Hosur, India (FEI 3004094136) at the end of a drug inspection that ended August 2, 2024. It lists 6 observations. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on January 16, 2025.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Aug 28, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Aug 2, 2024
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Aug 28, 2024
26 days after the inspection
Facility
FEI 3004094136
Hosur, India

The 6 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Incomplete or falsified production records

    Production records do not contain complete information relating to the production and control of each batch. The Production Head stated that he directed employees to create batch records and supporting records including cleaning records and equipment use logs for activities that did not actually occur in Plant [®®Plant®®is intended to be used for the manufacturing of the US market product ©9 Injection Grade APL The Plant ®®Manager stated he used Microsoft Excel to generate plans with dates, production start and stop times, sampling dates, and product weights to instruct employees how to create these records for activities that did not occur. Production employees present P9 of Plant ®@ participated in the creation of these batch records, cleaning records, and equipment logs for activities that did not occur. Duplicate sets of cleaning records and equipment logs were created for the same time period and document different batches being manufactured on the same equipment, at the same time. On July 29, 2024, examples of the plans, which were identified by the manager of Plant®®as being used in the fabrication of batch records for activities that did not occur, were observed in the Plant production office attached to blank batch records. This included plans associated with ©@ batches, 9 powder [P®Batches), ©9 Liquid [§ batches), and EB batch). All Microsoft Excel files present on the Plant ®®Manager’s computer, where the plans for fabricating batch records were created, were deleted by the Production Head on the evening of July 29, 2024, preventing additional plans that may have been present on the computer from being reviewed during the inspection. Review of batch records, cleaning records, and equipment use logs for [/#®® Injection API released for the US market identified the following conflicts that demonstrate the records are not accurate, since at least January of 2023: 1. [© injection API batch! ‘was batch OS that ‘was shipped on for supply to the US market. The batch record had not yet been reviewed and approved by QA as of July 29, 2024. Review of the [19%batch had the following conflicts in its batch record, equipment use log, and cleaning record documentation: The batch record and equipment use log for [Oe 16, 01 show the batch was from to [|] on This conflicts with the batch record for batch ‘which documents use of the same from [109 to[109 on Duplicate sets of equipment use and cleaning logs documenting these different products were made. The batch record and equipment use log for [TT O®02109 02 show the batch was from to on This conflicts with the batch record for batch and a different | @/0: /02 equipment log, which document use of the same from to on[®€ The batch record and equipment use log for: 0209/03 show the batch was in the from on until on This conflicts with the batch record for batch and a different = 0: /03 equipment log, which document use of the same from to on The Plant Work Report Sheet was described by the Plant Manager as a log that documents the activities occurring and documents what equipment is being used, as a form of communication between the For the Plant Work Report Sheet make references to batches and manufacturing in Plant but no references to any [®® manufacturing in Plant on these days. 2. Injection API batch TOE was |] atc] and distributed on for the US market. QA review and release had not been completed for the batch or the batch as of July 29, 2024. [| Injection API batch [TO0 had the following conflicts in its batch record, equipment use log, and cleaning record documentation: The batch record and equipment use log for [Oe 16, /01 show the batch was in [179 from to [|] on This conflicts with the batch records for batch which documents use of the same from [on to on and batch which documents the used of the same from to on Duplicate sets of equipment use and cleaning logs documenting these different products were made. The batch record and equipment use log for: 02/17/02

    Shortened here; the PDF has the full text.

  2. 2

    Document issuance and control failures

    Procedures for issuance and controls of documents are not followed. 1. QA issues duplicate equipment use logs and cleaning logs with the same issuance number. These duplicate logs are used in creation of records that document activities that did not occur. QA subsequently reviews and approves both sets of contradictory records. 2. The QC laboratory keeps uncontrolled notebooks which contain measurements associated with assay, LOD, pH, uncontrolled sample weights, etc. During the inspection employees were observed transcribing measurements from these uncontrolled pages into controlled test reports. Review of pages revealed testing for products manufactured in the different blocks including © injection reported to be manufactured in Plant[®®

  3. 3

    Missing or inadequate stability program

    An on-going testing program to monitor the stability characteristics of APIs is not established and followed. 1. 2023 yearly stability samples for’ 9 batch ®® 3s required by Protocol STB/23/ ©9/001/00 could not be located. These samples were confirmed to be representative of commercial product distributed to the US market. 2. @9 samples for batches ©9 and P9 were observed inside stability chamber QC 90, but your site did not have a protocol for these samples which described packaging, number of samples, and conditions of storage. In addition, the samples for these batches were kept in 9 bags but the three additional stability samples kept for investigation purposes were kept inside ©9 bags. These samples were confirmed verbally to be representative of the commercial product for the US market. 3. Protocol STB/21 9.24/00 - @9 for the year 2021, requires samples of batches EB © and “to be monitored for 60 months. These samples could not be located inside stability chamber QC 90. 4. Samples for ©9batch ®9 did not have a sample for 24-month time point as required by Protocol STB/23/ ®®-USP/002/00. The 24-month time point is due for testing in March of 2025. ©9 API has been distributed to the US market. 5. Samples for ©9 Jot ®® only had two (2) additional investigational samples instead of three (3) as described by Protocol STB/24/ ©®_USP/002/00. There have been no documented investigations. 6. PDstability samples for lot © as required by Protocol STB/23 ©9/001/00 could not be located. 7. 9 injection USP stability sample set for lot 9 did not have a sample for the 48-month time point. The 48-month time point sample is due for testing in May 2026. In addition, no protocol for this lot could be provided. 8. There are no records of the transfer of samples located inside stability chamber QC 89 to stability chamber QC 90, when chamber QC 89 stopped working. 9. The methods used for stability testing of © injection USP have not been shown to be stability indicating.

  4. 4

    Inadequate impurity profiling

    Established impurity profiles for US market APIs are inadequate. Impurity profiles describing the identified and unidentified impurities present in a typical batch of US market APIs oc SEO cron USP, [EE SO 1 [Mave not been sais The document provided as impurity profile does not include the identity or some qualitative analytical designation such as retention time and classification of each identified impurity (e.g., inorganic, organic, solvent, etc).

  5. 5

    Unidentified liquid contaminating equipment area

    Facility and equipment are not maintained in a manner that prevents contamination of APIs by other materials. On July 30, 2024, unidentified liquid was observed surrounding the pipe which transfers This area is located the area. Similar [1®9 liquid was also observed dripping from the ceiling pipe junctions in the area. The liquid was dripping on the floor and cover of the |] equipment. This area is where 1s awe manually [0 RR

  6. 6

    Undocumented deviations not investigated

    Deviations from established procedures were not documented in batch records and investigated. 1. The Plant Work Report Sheet identifies on May 22, 2024, the indicator malfunctioned and the raised in[[§ above the to during batch This caused the It states an extra material was added. None of this information is written in the batch record or further investigated for [oe batch which used [09 #1 on May 22, 2024. There is no associated maintenance records for the indicator. 2. The Plant Work Report Sheet identifies on June 3, 2024, that during of the [TP9_01 ©9 was broken and it was changed. This was not documented in the batch record for P9 batch © in any maintenance record, or further investigated.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3004094136, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.