FDA has 4 inspections on file for Global Calcium Private Limited in Hosur, India (FEI 3004094136), from 2015 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. One of the 10 FOIA requests for this site asked FDA for the 483 from a later inspection, ending Feb 20, 2026, that FDA's Data Dashboard doesn't list yet.

The most recent OAI inspection ended on Aug 2, 2024. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant is GLOBAL CALCIUM PRIVATE LIMITED (D-U-N-S 650425986).

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
4, 2015–2026
1 OAI · 3 VAI · 0 NAI
Inspections with 483 observations shown
2 of 4
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
10 requests, latest FY2023
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Unreliable microbiology records

      OBSERVATION 1 Laboratory records do not include complete data to assure compliance with established specifications Specifically, Microbiology laboratory data is unreliable. For example, the following discrepancies were observed between the individual microbial growth counts recorded in your laboratory-controlled records and the actual counts observed in your growth media plates, which had been read by your microbiologists. On January 27, 2026, and January 28, 2026, we observed that your microbiologist while performing Total Aerobic Microbial Count (TAMC) for (b)(4) Water (b)(4) combined colonies as one and failed to classify plate counts as Too Numerous to Count (TNTC). For example, Media ID: [illegible] Incubation Date: (b)(4) According to your QC microbiology management, your firm uses two levels [illegible] are accurately reconciled. It was observed that the second analyst verification only consists [illegible] a microbial growth recount is not performed. Your microbiology analyst stated that, during the colony counting process, individual colonies observed to contact are counted as one colony and not enumerated individually. According [illegible] not receive any visual training by your Microbiology Department on how to identify and classify a plate reading as TNTC. Since August 2025, your microbiology analyst has [illegible] (b)(4) water samples. (b)(4) water is used as a raw material in your manufacturing process (b)(4).

    2. Observation 2

      Inadequate sampling access controls

      OBSERVATION 2 Established sampling plan and test procedures are not [illegible] Specifically, we reviewed the biometric access control system (eSSL Security at Fingertips) for the Room (b)(4) located in Plant (b)(4) in where the (b)(4) water system is located, and observed the following deficiencies: A. Your Microbiology Officer employee documented in Allocation and Water Sampling Register that he collected laboratory testing on the following dates and times: Sample A.R. Number: (b)(4). However, the biometric access control system that limits access to the area does not show that employee entered that room during those dates. During my interview with your microbiology employee (b)(6) he explained that he always enters the sampling room using the biometric access panel and always performs water sampling by himself. B. Your Quality Control employee ID documented in form QCMI022-F07-00, "Water Sampling Register- Quality Control" that he collected (b)(4) Water (b)(4) samples on the following dates and times: Sample A.R. Number: (b)(4). However, the biometric access control system that limits access to the area does not show that employee entered that room during those dates. During my interview your Quality Control employee (b)(6) explained that he always enters the sampling room using the biometric access panel and always performs water sampling by himself. In addition, the biometric access system shows your Quality Control employee ID entered the room on January 9, 2026, at 11:06 AM. Form QCM1022-F07-00, titled "Water Sampling Register- Quality Control" shows that the (b)(4) Water (b)(4) sample A.R. Number: (b)(4) was collected at 11:06 AM but by a different employee (ID (b)(6)). C. Your Quality Control employee ID documented in form QCMI022-F01-01, "AR. Number" that he collected (b)(4) Water (b)(4) samples on the following dates and times: Sample A.R. Number: (b)(4). However, the biometric access control system that limits access to the area does not show that employee entered that room during those dates. During my interview he explained that he always enters the sampling room using the biometric access panel and always performs water sampling by himself. D. Your Microbiology Officer employee documented in Allocation and Water Sampling Register that on December 12, 2025, at (b)(4) the (b)(4) sample A.R. Number: (b)(4) was collected. However, the biometric access control system that limits access to the area does not show that employee entered that room during those dates. During my interview the employee explained that he always enters the sampling room using the biometric access panel and always performs water sampling by himself. Investigation Number: DEV/1/26/001 was initiated after these discrepancies were brought to the attention of management. At the conclusion of the inspection, no system communication errors, or other malfunctions were identified. Investigation DEV/1/26/001 was still ongoing. (b)(4) Water (b)(4) samples collected by your Quality Control personnel are tested by your Quality Control (QC) laboratory for microbiological analysis, Bacterial Endotoxin Test (BET), chemical analysis, and Total Organic Carbon (TOC) to ensure that (b)(4) Water meets established specifications. (b)(4) is used by your firm as a raw material in the manufacturing process.

    Show observations 3 to 6
    1. Observation 3

      BET incubation and reading issues

      OBSERVATION 3 Laboratory controls do not include the establishment procedures designed to assure that in-process materials conform to established specifications Specifically, on January 28, 2026, we observed the preparation and reading of the Bacterial Endotoxin Test following your procedure titled "Bacterial Endotoxin Test", SOP Number: QCMI011-00, Effective Date: April 17, 2025. It was observed that your firm failed to provide the conditions needed (no vibration) to prevent disturbance of the samples during incubation and allow proper gel formation. The incubator was not vibrating during the (b)(4) incubation period (b)(4). Additionally, a semi solid gel formation was observed in a negative result. Also, gel formation was observed in water point (b)(4) where liquid was observed running down the test tube; the analyst classified the sample as a negative. According to your microbiologist, since he started performing the test in January 2025, he has always performed the Bacterial Endotoxin Test using the same incubator, instead of following the specified incubation conditions. During the inspection he also explained that at times he performs the test results on (b)(4) water routine samples. Since August 2023, your firm has approximately performed the [illegible] samples, encompassing your Active Pharmaceutical [illegible], and no discrepant/atypical/invalid results have been observed. (b)(4) water is used as a raw material in the manufacturing process and these BET results are not reproducible.

    2. Observation 4

      Inadequate cleaning and verification

      OBSERVATION 4 Cleaning procedures are not appropriate or reproducible to prevent contamination that would alter the safety, identity, strength, quality, or purity of the finished drug substances. Your (b)(4) cleaning activities for non-dedicated equipment and used in the manufacturing of (b)(4) are inadequate. For example, but not limited to: 1) According to your procedure titled "Equipment Cleaning" PD033-F01(V-1), Operation Number (b)(4) states (b)(4). On February (b)(4) the operator replicated the cleaning procedures (b)(4). The total volume of (b)(4) used did not account for the combined volume of (b)(4) used in all instructions. In addition, your operator demonstrated that the (b)(4) with a capacity of (b)(4) was performed until the tank was (b)(4). The (b)(4) is optional and is only performed if (b)(4) is necessary. 2) According to your procedure titled "Equipment Cleaning Record for" PD033-F01(V-1), Operation Number (b)(4) (b)(4). On February (b)(4) the operator documented this step and explained that the form does not require him to document the cleaning step or volume added into the (b)(4). 3) According to your procedure titled "Equipment Cleaning Record" PD033-F01(V-1), Operation Number (b)(4) (b)(4) the operator did not follow the cleaning procedures of this step and explained that (b)(4) steps are [illegible]. The total volume of (b)(4) water used did not represent the combined volume of (b)(4) water used in all instructions. In addition, your operator demonstrated that (b)(4) with a capacity of (b)(4) (b)(4) was performed with the use of (b)(4). 4) There is no comprehensive, data-driven assessment demonstrating that cleaning verification of non-dedicated equipment is adequate. There is no empirical evidence such as residue trend data or risk-based rationale to justify that the verification interval of (b)(4) is representative. Similar deficiency was observed for the cleaning verification of (b)(4).

    3. Observation 5

      Weak data integrity controls

      OBSERVATIONS Failure to establish and maintain an effective Quality System to ensure the employees can report GMP-related concerns without fear of identification or retaliation. A. Your procedure titled "Data Integrity: SOP Number: QA058-04, Effective Date: January 07, 2025, Approved On: December 19, 2024, Section 4.22 states that a Data Integrity Check will be performed (b)(4) and documented on checklist form QA058-F01. We observed that the checklist is limited and does not ensure that the firm remain in place. It does not include any thorough assessment to determine whether the DI controls in place are being consistently followed in practice and no data integrity breach has occurred. For example, 1. The verification to determine if data is contemporaneously recorded is limited to notebooks. No actual observation of the employees carrying out documentation duties is made to ensure that data is documented at the time of occurrence. 2. The review of verification by a second person is limited. No actual observation of the employees carrying out the duties is made to ensure that the verification by a second person is being performed and documented. 3. The review evaluates if original records are read but no inspection of the original data is performed. 4. An instrument calibration review is performed by inspecting equipment calibration labels. However, no actual verification of calibration raw data is performed. 5. The review of times entered on controlled documents is performed by only reviewing logbooks. No actual observation of the employees carrying out documentation duties is made to ensure they are entering the correct time and date at the time of occurrence. During your approved data integrity checklist, no assessment is performed to cross-reference equipment use/cleaning logbooks and manufacturing batch records to challenge the documented data. Furthermore, procedure QA058-04 does not require a minimum representative sample of documents to be evaluated, or how these documents are selected. B. Your corrective action to implement an anonymous complaint box: the complaint box was located at the main entrance in an area routinely used by employees to access the biometric lunch token system. This location compromises employee anonymity and may discourage the reporting of GMP concerns.

    4. Observation 6

      Quality Unit oversight inadequate

      OBSERVATION 6 The responsibilities of your Quality Unit are not adequate. A. Your Quality Unit failed to fulfill its commitment to conduct a third party review of all batches manufactured during the calendar years 2022 to 2024. For example, your firm did not conduct a comprehensive evaluation of all batches manufactured for the USA market to determine the extent of deviations during the previous inspection on August 2, 2024, and a reconciliation of incoming raw materials and test results, samples collected, and batch production records among others were evaluated to determine whether additional discrepancies in the manufacturing operations had occurred as cited in WL 320-25-30. Without a justification, your Quality Unit followed (b)(4) to evaluate the production records of the batches manufactured in 2022 and 2023. (b)(4) were evaluated from a total of (b)(4) batches manufactured during that period. B. Your protocol Document No. STY/P/QA/003-00 titled "Protocol For Comprehensive Assessment On Data Integrity Assurance", approved on January 21, 2025, is inadequate to perform a comprehensive assessment of the integrity of data across Quality, Manufacturing, and Engineering departments. A checklist was designed for each functional area to assess compliance. However, the result of this assessment only provides information on the control procedures established in each of the referenced departments for assessing/investigating events that could be associated to data integrity. For example, there is no information related to the computer systems, including the user privileges, the equipment logbooks for manufacturing/packaging/calibration/qualification/preventive maintenance/analytical records that were evaluated as part of the requirements of Protocol STY/P/QA/003-00.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Incomplete or falsified production records

      Production records do not contain complete information relating to the production and control of each batch. The Production Head stated that he directed employees to create batch records and supporting records including cleaning records and equipment use logs for activities that did not actually occur in Plant [®®Plant®®is intended to be used for the manufacturing of the US market product ©9 Injection Grade APL The Plant ®®Manager stated he used Microsoft Excel to generate plans with dates, production start and stop times, sampling dates, and product weights to instruct employees how to create these records for activities that did not occur. Production employees present P9 of Plant ®@ participated in the creation of these batch records, cleaning records, and equipment logs for activities that did not occur. Duplicate sets of cleaning records and equipment logs were created for the same time period and document different batches being manufactured on the same equipment, at the same time. On July 29, 2024, examples of the plans, which were identified by the manager of Plant®®as being used in the fabrication of batch records for activities that did not occur, were observed in the Plant production office attached to blank batch records. This included plans associated with ©@ batches, 9 powder [P®Batches), ©9 Liquid [§ batches), and EB batch). All Microsoft Excel files present on the Plant ®®Manager’s computer, where the plans for fabricating batch records were created, were deleted by the Production Head on the evening of July 29, 2024, preventing additional plans that may have been present on the computer from being reviewed during the inspection. Review of batch records, cleaning records, and equipment use logs for [/#®® Injection API released for the US market identified the following conflicts that demonstrate the records are not accurate, since at least January of 2023: 1. [© injection API batch! ‘was batch OS that ‘was shipped on for supply to the US market. The batch record had not yet been reviewed and approved by QA as of July 29, 2024. Review of the [19%batch had the following conflicts in its batch record, equipment use log, and cleaning record documentation: The batch record and equipment use log for [Oe 16, 01 show the batch was from to [|] on This conflicts with the batch record for batch ‘which documents use of the same from [109 to[109 on Duplicate sets of equipment use and cleaning logs documenting these different products were made. The batch record and equipment use log for [TT O®02109 02 show the batch was from to on This conflicts with the batch record for batch and a different | @/0: /02 equipment log, which document use of the same from to on[®€ The batch record and equipment use log for: 0209/03 show the batch was in the from on until on This conflicts with the batch record for batch and a different = 0: /03 equipment log, which document use of the same from to on The Plant Work Report Sheet was described by the Plant Manager as a log that documents the activities occurring and documents what equipment is being used, as a form of communication between the For the Plant Work Report Sheet make references to batches and manufacturing in Plant but no references to any [®® manufacturing in Plant on these days. 2. Injection API batch TOE was |] atc] and distributed on for the US market. QA review and release had not been completed for the batch or the batch as of July 29, 2024. [| Injection API batch [TO0 had the following conflicts in its batch record, equipment use log, and cleaning record documentation: The batch record and equipment use log for [Oe 16, /01 show the batch was in [179 from to [|] on This conflicts with the batch records for batch which documents use of the same from [on to on and batch which documents the used of the same from to on Duplicate sets of equipment use and cleaning logs documenting these different products were made. The batch record and equipment use log for: 02/17/02

      Shortened here; the PDF has the full text.

    2. Observation 2

      Document issuance and control failures

      Procedures for issuance and controls of documents are not followed. 1. QA issues duplicate equipment use logs and cleaning logs with the same issuance number. These duplicate logs are used in creation of records that document activities that did not occur. QA subsequently reviews and approves both sets of contradictory records. 2. The QC laboratory keeps uncontrolled notebooks which contain measurements associated with assay, LOD, pH, uncontrolled sample weights, etc. During the inspection employees were observed transcribing measurements from these uncontrolled pages into controlled test reports. Review of pages revealed testing for products manufactured in the different blocks including © injection reported to be manufactured in Plant[®®

    Show observations 3 to 6
    1. Observation 3

      Missing or inadequate stability program

      An on-going testing program to monitor the stability characteristics of APIs is not established and followed. 1. 2023 yearly stability samples for’ 9 batch ®® 3s required by Protocol STB/23/ ©9/001/00 could not be located. These samples were confirmed to be representative of commercial product distributed to the US market. 2. @9 samples for batches ©9 and P9 were observed inside stability chamber QC 90, but your site did not have a protocol for these samples which described packaging, number of samples, and conditions of storage. In addition, the samples for these batches were kept in 9 bags but the three additional stability samples kept for investigation purposes were kept inside ©9 bags. These samples were confirmed verbally to be representative of the commercial product for the US market. 3. Protocol STB/21 9.24/00 - @9 for the year 2021, requires samples of batches EB © and “to be monitored for 60 months. These samples could not be located inside stability chamber QC 90. 4. Samples for ©9batch ®9 did not have a sample for 24-month time point as required by Protocol STB/23/ ®®-USP/002/00. The 24-month time point is due for testing in March of 2025. ©9 API has been distributed to the US market. 5. Samples for ©9 Jot ®® only had two (2) additional investigational samples instead of three (3) as described by Protocol STB/24/ ©®_USP/002/00. There have been no documented investigations. 6. PDstability samples for lot © as required by Protocol STB/23 ©9/001/00 could not be located. 7. 9 injection USP stability sample set for lot 9 did not have a sample for the 48-month time point. The 48-month time point sample is due for testing in May 2026. In addition, no protocol for this lot could be provided. 8. There are no records of the transfer of samples located inside stability chamber QC 89 to stability chamber QC 90, when chamber QC 89 stopped working. 9. The methods used for stability testing of © injection USP have not been shown to be stability indicating.

    2. Observation 4

      Inadequate impurity profiling

      Established impurity profiles for US market APIs are inadequate. Impurity profiles describing the identified and unidentified impurities present in a typical batch of US market APIs oc SEO cron USP, [EE SO 1 [Mave not been sais The document provided as impurity profile does not include the identity or some qualitative analytical designation such as retention time and classification of each identified impurity (e.g., inorganic, organic, solvent, etc).

    3. Observation 5

      Unidentified liquid contaminating equipment area

      Facility and equipment are not maintained in a manner that prevents contamination of APIs by other materials. On July 30, 2024, unidentified liquid was observed surrounding the pipe which transfers This area is located the area. Similar [1®9 liquid was also observed dripping from the ceiling pipe junctions in the area. The liquid was dripping on the floor and cover of the |] equipment. This area is where 1s awe manually [0 RR

    4. Observation 6

      Undocumented deviations not investigated

      Deviations from established procedures were not documented in batch records and investigated. 1. The Plant Work Report Sheet identifies on May 22, 2024, the indicator malfunctioned and the raised in[[§ above the to during batch This caused the It states an extra material was added. None of this information is written in the batch record or further investigated for [oe batch which used [09 #1 on May 22, 2024. There is no associated maintenance records for the indicator. 2. The Plant Work Report Sheet identifies on June 3, 2024, that during of the [TP9_01 ©9 was broken and it was changed. This was not documented in the batch record for P9 batch © in any maintenance record, or further investigated.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

10 requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.

  • Inspection ending Feb 20, 2026

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Mar 18, 2026. FDAgent holds no copy that FDA posted.

    1. Mar 16, 2026FDA-FOIA-2026-2626Form 483Records released
  • Inspection ending Jan 27, 2026

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Feb 19, 2026. FDAgent holds no copy that FDA posted.

    1. Feb 16, 2026FDA-FOIA-2026-1590Form 483Records released
  • Inspection ending Aug 2, 2024OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Aug 12, 2024FDA-FOIA-2024-7139Form 483Closed
  • Inspection ending Jul 2, 2024

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. Aug 22, 2024FDA-FOIA-2024-7462Form 483· 1 of 3 sitesClosed
  • Inspection ending Feb 22, 2019VAI

    3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Oct 19, 2026. FDAgent holds no copy that FDA posted.

    1. FY2023FDA-FOIA-2022-8464Form 483 + EIRClosed
    2. FY2023FDA-FOIA-2022-8282EIRWithdrawn
    3. Oct 14, 2026FDA-FOIA-2026-10007Form 483Records released
  • Inspection ending Apr 10, 2015VAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Oct 19, 2026. FDAgent holds no copy that FDA posted.

    1. Oct 14, 2026FDA-FOIA-2026-10006Form 483Records released
  • Inspection date not given

    2 requests. FDA released records in answer to a request for its Form 483 on Apr 22, 2026. FDAgent holds no copy that FDA posted.

    1. Apr 9, 2026FDA-FOIA-2026-3577Form 483Records released
    2. Aug 7, 2024FDA-FOIA-2024-7081Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing, analysis
Registration runs through
Dec 31, 2027
Registrant
GLOBAL CALCIUM PRIVATE LIMITEDD-U-N-S 650425986

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004094136 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004094136. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.