Skip to content

Fukuzyu Pharmaceutical Co., Ltd.

48, Hagihara, Toyama, Japan

FEI 3002807025DUNS 692442510

FDA has 4 inspections on file for Fukuzyu Pharmaceutical Co., Ltd. in Toyama, Japan (FEI 3002807025), from 2013 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. One of the six FOIA requests for this site has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Jan 19, 2024. No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant is Fukuzyu Pharmaceutical Co., Ltd. (D-U-N-S 692442510).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
4, 2013–2025
1 OAI · 3 VAI · 0 NAI
Inspections with 483 observations shown
1 of 4
Form 483s posted by FDA
↗
Requested under FOIA
6 requests, latest Feb 27, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Incomplete OOS investigations and CAPAs

      The quality unit does not always conduct thorough investigations for out-of-specification results and critical deviations. Specifically, A) Your firm opened OOS 220202-1 on 02/02/2022 to investigate the OOS result for ----- assay in (b)(4) (b)(4) (b)(4) (b)(4). The reprocessed rate of the initial results was [illegible] which exceeds the (b)(4) specification of (b)(4). The investigation indicated the most likely root cause of the OOS was weighing error caused by static electricity or vibration, but there was no written scientific justification to support this conclusion. The weigh tickets attached to the testing record indicate the correct amounts or materials were used. There is no explanation how static electricity contributes error to an analytical balance, quantification of the error, and a determination that the error could cause the OOS result observed. Your firm opened CAPA 220209-1 to install an ionizer that would reduce static electricity without adequate scientific justification to support implementation of this change as a corrective action. Your firm invalidated the original OOS result and then distributed 1 batch on about [illegible]. B) Your firm opened OOS 211221-1 on 12/21/2021 to investigate the OOS result for DMF residual solvent in (b)(4) (b)(4) (b)(4) (b)(4) API, batch [illegible]. The initial result was [illegible] ppm, and the API specification is (b)(4) ppm. The investigation identified residual DMF as not uniform in the API drums (3 of [illegible] drums were OOS), and the conclusion indicates inadequate [illegible] as the likely root cause. Your firm reprocessed the OOS batch as [illegible] without adequate investigation and follow-up. i. Your firm opened deviation 211228-1 and CAPA 220323-1 in response to the OOS investigation 211221-1. The deviation and CAPA did not include a thorough investigation of the potential impact the identified root cause of inadequate [illegible] had on previous lots of (b)(4) API that were (b)(4) for the same amount of time and [illegible]. ii. Your firm conducted a (b)(4) uniformity study using (b)(4) API batch [illegible] in 2013. CAPA 220323-1 appeared to increase the ability to detect inadequate (b)(4) for future batches, but deviation 211228-1 did not investigate the need to perform a new or more thorough uniformity study. iii. Your firm did not take adequate corrective and preventive action after a DMF residual solvent IPC result for batch (b)(4) exceeded the API specification of (b)(4) ppm. Additionally, records indicate all four (b)(4) batches I reviewed that were manufactured since 2019 failed to meet the residual DMF IPC target of (b)(4) ppm. API include batch (reprocessed to [illegible]), batch (reprocessed to [illegible]), and batch (b)(4).

    2. Observation 2

      Inadequate cleaning preventing cross-contamination

      Shared production equipment is not always cleaned and maintained in a manner suitable to prevent cross contamination of non-hazardous API by hazardous substances. Specifically, On 01/16/2023, I observed apparent residue and particulates inside the L__ housing of S-7 and the product (b)(4) (b)(4). The [illegible] equipment was estimated clean after cleaning verification with rinse samples, swab samples, and visual inspection was complete. These are the processing steps before filling and packaging. Equipment use logs indicate your firm used this equipment to manufacture API and other hazardous and non-hazardous substances. y-c API include batch (b)(4) lot (b)(4), batch (b)(4) lot (b)(4), batch (b)(4) lot (b)(4). B) Your cleaning procedures are not validated to inactivate all the hazardous substances manufactured using shared equipment. Your firm does not have a written procedure to evaluate the ability of cleaning procedures to remove residues of (b)(4) and (b)(4) API produced using equipment shared with commercial API. Equipment use and cleaning logs indicate operators used S-7 to process a (b)(4) API before [illegible]. Your firm distributed this batch on about (b)(4). Standard Solution X and Standard Solution Y both failed to meet the solution stability acceptance criteria of (b)(4) listed in the approved cleaning validation protocol PYR-2015-02 during the initial test and during the retest with newly prepared standard solutions. Solution X was stable for (b)(4) and Solution Y was stable for (b)(4) during the initial test. Solution X was stable for [illegible] and Solution Y was stable for [illegible] during the retest. Your firm approved the cleaning validation report for PYR-2015-02 using the linearity, LOQ, and range data from the first set of standard solutions combined with the solution stability data from the second set of standard solutions. There was no investigation, no scientific justification to accept data from standards that failed stability, and no written justification to accept sample stability that did not meet the acceptance criteria. Your firm relies on cleaning verification samples to detect and prevent cross-contamination between hazardous and non-hazardous API.

    Show observations 3 to 4
    1. Observation 3

      Incomplete analytical method validation

      Validation of analytical methods is incomplete. Specifically, your firm did not provide records during this inspection that documented analysts in your laboratory performed method validation, verification, or transfer for the in-house gas chromatography (GC) residual solvents method used to analyze samples for release testing of (b)(4). Your firm used results from this method to release all (b)(4) API, including batch (b)(4) lot (b)(4) that was distributed on about (b)(4).

    2. Observation 4

      Insufficient computerized system controls

      Appropriate procedures are not established and followed for control of computerized systems and electronic records in the QC laboratory. Specifically, A) The Vice Manager of QA is the sole administrator for Empower 3 software used to collect and process data from multiple chromatography instruments in your laboratory. On 01/18/2023, I observed the Vice Manager of QA login to the software as the administrator and then access system policies, audit trails, and stored data for (b)(4). The list of permissions for the Administrator user type indicated the user has unlimited ability to change or delete electronic records. The Vice QA Manager is responsible for oversight of API release. Your firm used Empower 3 software to process chromatographic data used to release (b)(4) batch (b)(4) lot (b)(4). B) The Shimadzu C-R8A Chromatopac integrator connected to GC-06, asset number QC-0011, does not have features to enable robust data integrity. There is no forced data saving and no audit trail. The system erases electronic files when it is turned off, and I observed the system was not powered on during my review of the laboratory. Analysts use floppy disks to transfer files from the system to an unsecure file on a computer accessible to all QC staff as a backup. There is inadequate assurance quality personnel review all QC records produced by this system prior to making release decisions. Your firm used this system to perform residual solvents analyses for (b)(4) (b)(4) (b)(4) and release API batch lot (b)(4), batch lot (b)(4), and batch lot (b)(4).

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Six requests to FDA under the Freedom of Information Act named this site, most recently on Feb 27, 2026.

  • Inspection ending Nov 11, 2025VAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Mar 18, 2026. FDAgent holds no copy that FDA posted.

    1. Jan 9, 2026FDA-FOIA-2026-314Form 483· 1 of 2 sitesRecords released
  • Inspection ending Jan 19, 2024OAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Feb 27, 2026FDA-FOIA-2026-2053Form 483Records released
    2. Sep 5, 2024FDA-FOIA-2024-7923Inspection recordsClosed
  • Inspection ending Mar 8, 2023

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Feb 3, 2026. FDAgent holds no copy that FDA posted.

    1. Jan 30, 2026FDA-FOIA-2026-903Form 483· 1 of 3 sitesRecords released
  • Inspection date not given

    2 requests. FDA released records in answer to a request for its Form 483 on Jan 8, 2026. FDAgent holds no copy that FDA posted.

    1. Dec 17, 2025FDA-FOIA-2025-14157Form 483Records released
    2. Feb 21, 2024FDA-FOIA-2024-1874Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2027
Registrant
Fukuzyu Pharmaceutical Co., Ltd.D-U-N-S 692442510

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3002807025 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3002807025. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.