Divi's Laboratories Ltd. (Unit II)
Chippada Village, Annavaram, Bheemunipatnam Mandal, Visakhapatnam District, India
FEI 3004149463DUNS 676446492
Company: DIVI'S LABORATORIES LIMITED · Linked by exact D-U-N-S match (918523627) in FDA registration data
FDA has 8 inspections on file for Divi's Laboratories Ltd. (Unit II) in Visakhapatnam District, India (FEI 3004149463), from 2009 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. Two FOIA requests have asked FDA for this inspection's 483.
The most recent OAI inspection ended on Dec 6, 2016. FDA issued a warning letter on (CDER). 3 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant, DIVI'S LABORATORIES LIMITED (D-U-N-S 918523627), has registered 1 other site.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 8, 2009–2024
- 1 OAI · 5 VAI · 2 NAI
- Inspections with 483 observations shown
- 3 of 8
- Requested under FOIA
- 2 requests, latest Oct 28, 2024
- Warning letters
- · CDER ↗
- Import refusals
- 3 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate equipment cleaning procedures
Written procedures are not established for the cleaning of equipment used in the manufacture of (b)(4) API. Specifically, SOP "CLEANING PROCEDURES", SOP NO: PD/OP/0017, REV NO: 000, EFFECTIVE DATE: 01/01/2021, does not include provisions to clean or visually inspect the area (b)(4) (b)(4) (b)(4) behind the (b)(4) of (b)(4) are used in the manufacture of (b)(4)
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to assay final API batches
OBSERVATION 1 Your firm failed to test individual batches of final API for conformity with all appropriate specifications such as purity, strength, and identity prior to Specifically, your firm does not analyze for assay for all final API batches prior to. The following final API products were found to not be analyzed for assay: "Active Pharmaceutical Ingredient Number of final batches not analyzed for Assay prior to in2016 Number of final batches not analyzed for Assay prior to in2017 [illegible table rows]
- Observation 2
Inadequate OOS investigations
OBSERVATION 2 Laboratory failures are not thoroughly investigated. Specifically, Out of Specification (OOS) investigations where laboratory error was not clearly identified were invalidated without adequate investigation into manufacturing, process, maintenance, and engineering activities. For example: (b) (4) (b) (4) a. Investigation No./ 2-PLV/OOS/IP-IM/W/012 for lot number [illegible] any other individual impurity out of specification ([illegible] % w/w, Spec of [illegible] % w/w), preliminary investigation did not identify laboratory error. Your preliminary laboratory investigation on February 20, 2017, interviewed that analyst on sample analysis, preparation of sample, environment and glassware and found no errors. Your March 03, 2017 extended preliminary laboratory investigation report, described data obtained from fresh preparation analysis is not comparable to initial analyzed data as the peak did not elute. Your further investigation report dated March 12, 2017, into the peak identified the peak as being [illegible] which also [illegible] manufactured at your site. Your gap analysis report shows your analyst stating he cleaned the balance area and weighing pan before performing weighing activity and taken precautions during sample transfer. However, you concluded that this was a cross contamination in your laboratory. Your investigation also shows that the same impurity has eluted in 17 other previous batches. Your documented manufacturing investigation only verified that there was no deviation being reported in the batch records and operations were followed. There was no thorough investigation into manufacturing, process, maintenance, and engineering activities and involved the relevant departments that may have attributed to batch contamination. Original results were invalidated without clear identification of laboratory error and adequate investigation into manufacturing, process, maintenance, and engineering. Original results were invalidated and batch was released using retest results. In addition, another OOS investigation (No./ 2-PL/I/OOS/IP-IM/W/010) initiated 5 days prior to this OOS for an impurity eluting at the same relative retention time was attributed to another cross contamination during sampling and original results invalidated. Within specification impurity at the same relative retention time has been quantified [illegible] times since the above OOS. b. Investigation No./ 2-PL/I/OOS/FF[illegible]/W/001 for lot number [illegible] any other individual impurity out of specification ([illegible] % w/w, specification [illegible] % w/w) your preliminary investigation report dated January 9, 2017, interviewed that analyst on sample analysis, preparation of sample, environment and glassware and found no errors. Reinjection and retest from HPLC bottle and bottle [illegible] analysis also showed that same impurity eluted in your sample at out of specification limits. The peak was identified by your laboratory as being [illegible] that is also manufactured at your site. Your extended investigation dated February 13, 2017, interview of your analyst performing activity as not performing any analysis before performing the [illegible]. You state that he performed secondary verification activities in ROI and LOD analysis and attributed the contamination coming from unhygienic hands due to lack of washing his hands after the secondary verification activity even though the analyst stated he performed the activity in clean and dedicated location, he has wiped his hands and did not observe any product on his hands. Batch resampling was authorized by QA on March 18, 2017 and passing resample was reported extended preliminary laboratory investigation report on April 12, 2017. Manufacturing investigation form was filled on June 2, 2017 after passing resample results and did not document adequate investigation into manufacturing, process development, maintenance, and engineering activities that may have attributed to
Shortened here; the PDF has the full text.
Show observations 3 to 6
- Observation 3
Analytical excursions not evaluated
OBSERVATION 3 Review of Analytical incident/excursion investigations as per your Atypical or out of trend results procedure (2-IRA/OP/03) showed instances in which samples injection sequence was completed but results were not calculated and/or compared to specification to ensure OOS results were not obtained and sample result screening is not occurring prior to invalidating the run for system suitability or chromatograph issues. For instance: a. On January 12, 2017, Incident 2-AT/FP[illegible]/W/002 was initiated after testing of 6 lots for theoretical plate count failure of peak in standard solution. Sample results were invalidated without evaluation of results to ensure OOS results were not obtained. b. On December 27, 2016, incident 2-AT/FF[V]/020 was initiated after testing of stability lot [illegible] (40C/75% RH, day 180) for baseline disturbance in sample preparation. System suitability was met and disturbance was attributed to air bubble in flow cell. Sequence was invalidated without evaluating and comparing of results to ensure OOS results were not obtained. c. On January 23, 2017, incident 2-AV/FP[illegible]/W/002 was initiated after testing of 6 lots for related compound and assay testing due to abnormal peak shape fronting at product peak in peak identification solution, sample solution and sample injections. System suitability was met. Peak was associated to mobile phase contamination or improper pH adjustment. Sequence was invalidated without evaluating and comparing of obtained results to ensure OOS results were not obtained.
- Observation 4
No cleaning time/validation documentation
OBSERVATION 4 Your firm has failed to validate the manufacturing cleaning length of time from [illegible] to the [illegible] of production runs for manufacturing equipment to ensure your cleaning procedures are effective for the removal of the build-up of contaminants, degradants and microbes. The length in the chemical synthesis production area is to include equipment such as: reactors, [illegible]. Equipment in the pharma blocks include: [illegible]. There is no documentation to ensure your cleaning procedures are effective to remove microbial contaminants in the worst case locations of the different equipment after the [illegible] length of [illegible] or of continuous production. For example, the last continuous production in the Pharma block for [illegible] was from [illegible] to [illegible]; batches of [illegible] were processed through the [illegible] and [illegible] before a complete clean was conducted. [illegible] batches of [illegible] were processed in the [illegible] during this [illegible].
- Observation 5
Inadequate cleaning instructions and records
OBSERVATION 5 Your firm does not have adequate cleaning instructions (Issue Control#5) for the major equipment in the Pharma block for [illegible]. Major equipment in the pharma blocks include: [illegible]. The batch cleaning record does not have detailed step by step instructions for how to clean the equipment, what parts to dismantle, supplies needed for cleaning, water temperature or pressure, and the volume of water needed for flushing the equipment.
- Observation 6
Batch records not contemporaneously completed
OBSERVATION 6 Batch records are not always recorded contemporaneously at the completion of an operation. For example: On 9/12/2017 during the production of [illegible] batch the in-charge production employee had signed the "CHECKED BY" column at step [illegible] in the manufacturing record to increase the batch [illegible] to [illegible]. However the "DONE BY" column was not signed by the chemist and the operation was not completed. On 9/12/2017 during the production of [illegible] batch, batch record operation step [illegible] displays the initials of the chemist and the in-charge manager had signed the "CHECKED BY" and "DONE BY" column as completed. However the operation time "TO" and "DURATION" details are not completed for the operation; as well as the volumes of the [illegible].
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate controls over chromatographic systems
OBSERVATION 1 Proper controls are not exercised over computerized systems used for analytical testing to ensure drug products meet their specified quality attributes. 1. Your firm engages in extensive use of “Inhibit Integration” and other anomalous integration techniques for assessing US APIs such that unknown impurities are disregarded without scientific justification. Furthermore, unknown impurities are not accurately assessed or reported. a. For example, below lists some APIs for the US market with corresponding use of inhibit integration: Inhibit Integration [illegible] This use of inhibit integration was used to mask unknown impurities for the [illegible]. (b) lot was released with an individual unknown impurity of [illegible]% against a specification of [illegible]% (this individual impurity was in the inhibit integration region of the chromatogram. Your firm stated that this peak had not been quantified against the specification, as it was early eluting and a separate method is utilized for assessing those impurities. This statement remained unsubstantiated throughout the inspection. No investigation of this impurity had been conducted. (c) [illegible] was released with total impurities of [illegible]% against a specification of not more than [illegible]%; however, a review of the raw data revealed that a known impurity termed impurity [illegible] had been integrated as a part of the desired peak, and therefore not considered in the calculation of total impurities. Your firm's Deputy General Manager QC acknowledged the presence of this impurity in the chromatogram, but declined the opportunity to explain how the product met specification. (d) A review of chromatograms from your firm’s last 30 batches of [illegible] revealed that there is an unknown peak eluting at a slightly longer relative retention time than the desired peak. Specifically, approximately half of the last 30 batches display this unknown peak that is integrated as a part of the desired API. Your firm's Deputy General Manager QC stated this is an unknown and uninvestigated impurity. (e) The chromatograms from your firm's forced degradation report (2-[illegible]/HPLC/003) does not display this peak, suggestive of a process or cross-contamination related impurity. (f) A review of chromatograms from your firm's last 30 batches of [illegible] revealed that unknown impurities are routinely integrated as a part of the desired API. Your firm's Deputy General Manager QC failed to explain why impurities would be as a part of the desired API peak. 2. [illegible] of your R&D Division’s chromatographic systems do not have audit trails enabled or enabled audit trails on November 27, 2016, the day before the initiation of the US FDA inspection. These chromatographic systems are utilized for GMP functions including: (i) Providing data to address DMF deficiencies (For Example: [illegible]) (ii) Performing investigations Furthermore, we observed drug product from production at R&D. Moreover, we noted obscurely named chromatographic sequences contained in these same systems, such as: a. [illegible], the name for “alternative process” b. [illegible], the name for a [illegible] c. [illegible], the name for BN d. [illegible], the name for [illegible] e. [illegible], the name for EB f. [illegible], the name for [illegible] g. [illegible], the name for [illegible]
- Observation 2
Equipment and facility contamination issues
OBSERVATION 2 Facilities and equipment are not maintained to ensure the purity, quality, strength and identity of the API Specifically, we observed the following deficiencies: 1. Unexplained [illegible] colored product was observed on a Pang 9 [illegible] stages of API manufacturing (i.e. [illegible] Block): (a) On 11/29/16, we observed your DUTP [illegible] 01 contained a colored residue inside the [illegible] comingled with product. This coloration is inconsistent with the [illegible] coloration of [illegible], a US API manufactured in Block [illegible]. (b) On 11/29/16, we observed your [illegible]-01 contained a colored residue inside the [illegible] used to [illegible] a US API manufactured in Block [illegible]. Your firm stated these residues were a [illegible] on the [illegible], however, wiping of the surface with a white cloth displayed a [illegible] appearance. This equipment was being utilized in a campaign manufacturing batch [illegible]. (c) On 11/29/16, we observed residue/staining on the product contact surface of the [illegible] of [illegible].03. In addition, a build-up of white residue was observed in the piping of the [illegible] which contains no separation from the contents inside the [illegible]. This equipment was being utilized in a campaign manufacturing batch [illegible]. The firm did not clarify how cross-contamination of the colored residue with API is avoided. API is intended for the US Market. (d) On 11/29/16, we observed your CP-01 contained colored material inside the [illegible] comingled with product. This coloration is inconsistent with the coloration of [illegible]. This [illegible] contained material from the batch [illegible] which was intended for further [illegible] per SOP 2-PD/GEN/57. (e) On 12/2/16, we observed [illegible] material in 3 of [illegible] being utilized in a campaign in [illegible] Block. Per SOP 2-3) D/29a, only the exterior surface of the [illegible] are cleaned during a campaign and therefore remains unclear how your firm avoids cross-contamination of batches manufactured. For points a-e listed above, we observed your firm had complaints associated with abnormal colored/stained material. For example, complaint 2-IR/ILD-003/[illegible]/2016/R was received for “Customer have found colored stain in [illegible].” Additionally, complaint 2-3-001, DO2015R was received for “Customer has observed dark particles in sample of [illegible].” 2. [illegible] used in product are not maintained (a) On 11/29/16, we observed particulates on the inner [illegible] of the [illegible] which were consistent with the color of the [illegible]. Additionally, white colored particulates were observed inside of the [illegible] after manufacturing of batch [illegible]. This [illegible] labeled “Last cleaned on 28/11/16 at 11:00", is used to manufacture for the US market. (b) On 11/29/16, we observed multiple areas of divets and chipping inside of [illegible] 02. This [illegible] labeled “Last cleaned on 29/11/16", is used to manufacture for the US market.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Oct 28, 2024. Each one asked for a Form 483.
Inspection ending Jul 19, 2024VAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Oct 28, 2024FDA-FOIA-2024-9564Form 483Closed
- Aug 26, 2024FDA-FOIA-2024-7520Form 483· 1 of 3 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3004149463, one row per refused product line.
3 refusals from 2017-04-10 to 2020-12-29 · charged DRUG GMPS on 2, UNAPPROVED on 1 · no FDA sample analysis
FDA firm profile- 2020-12-29
MICONAZOLE NITRATE (ANTI-FUNGAL) (NOT ANTIBIOTIC)61WCS18
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast ImportsSCS-2626386-5/11/1
- 2017-04-26
MESALAMINE (ANALGESIC)60LIR85
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports334-2782350-6/11/1
- 2017-04-10
PHENYLEPHRINE HCL (ADRENERGIC)60CAS09
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
REFUSE EI 801(a)(1); INSANITARY MANUFACTURING, PROCESSING OR PACKING
DRG REF EI 801(a)(3), 501(j); ADULTERATION
Division of Southeast ImportsBMB-0017166-8/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- DIVI'S LABORATORIES LIMITEDD-U-N-S 918523627
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names DIVI'S LABORATORIES LIMITED (D-U-N-S 918523627) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- DIVI'S LABORATORIES LIMITEDNalgonda, India · FEI 30031311365 inspections5latestNov 14, 2025NAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3004149463 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3004149463. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.